1,937 research outputs found

    Miniature battery-operated electromagnetic system for blood flow measurements

    Get PDF
    System consisting of solid state electronics package and a pair of standard flow-transducer cuffs is useful in cardiovascular studies. Device shows good zero stability and calibrations, and low noise levels

    Miniature bioelectric device accurately measures and telemeters temperature

    Get PDF
    Miniature micropower solid-state circuit measures and telemeters the body temperature of laboratory animals over periods up to two years. The circuit employs a thermistor as a temperature sensing element and an fm transmitter. It is constructed from conventional discrete components or integrated circuits

    Miniature telemetry system accurately measures pressure

    Get PDF
    Miniature, low power, telemetry system that can be used with commercially available strain gage pressure transducers accurately measures pressure with a small implantable pressure cell and transmitter. The system has been used to date only with pressure transducers, but the circuit is equally applicable to any measurement using a strain gage sensor

    Low power electromagnetic flowmeter providing accurate zero set

    Get PDF
    A low power, small size electromagnetic flowmeter system is described which produces a zero output signal for zero flow. The system comprises an air core type electromagnetic flow transducer, a field current supply circuit for the transducer coils and a pre-amplifier and demodulation circuit connected to the output of the transducer. To prevent spurious signals at zero flow, separate, isolated power supplies are provided for the two circuits. The demodulator includes a pair of synchronous rectifiers which are controlled by signals from the field current supply circuit. Pulse transformer connected in front of the synchronous rectifiers provide isolation between the two circuits

    Induction powered biological radiosonde

    Get PDF
    An induction powered implanted monitor for epidurally measuring intracranial pressure and telemetering the pressure information to a remote readout is disclosed. The monitor utilizes an inductance-capacitance (L-C) oscillator in which the C comprises a variable capacitance transducer, one electrode of which is a small stiff pressure responsive diaphragm. The oscillator is isolated from a transmitting tank circuit by a buffer circuit and all electric components in the implanted unit except an input and an output coil are shielded by a metal housing

    Miniature ingestible telemeter devices to measure deep-body temperature

    Get PDF
    A telemetry device comprised of a pill-size ingestible transmitter developed to obtain deep body temperature measurements of a human is described. The device has particular utility in the medical field where deep body temperatures provide an indication of general health

    Narrowband, crystal-controlled biomedical telemetry system

    Get PDF
    Telemetry system utilizing miniature, single-channel, crystal-controlled transmitter is described suitable for biomedical applications. Receiver used in conjunction with transmitter is narrowband superheterodyne FM receiver with crystal control in both conversion stages

    An ingestible temperature-transmitter

    Get PDF
    Pill-sized transmitter measures deep body temperature in studies of circadian rhythm and indicates general health. Ingestible device is a compromise between accuracy, circuit complexity, size and transmission range

    An inductively powered telemetry system for temperature, EKG, and activity monitoring

    Get PDF
    An implant telemetry system for the simultaneous monitoring of temperature, activity, and EKG from small animals, such as rats, was designed with the feature that instead of a battery the system is energized by an inductive field. A 250 kHz resonant coil surrounds the cage (30 x 30 x 20 cm) and provides the approximately 100 microns of power required to operate the implant transmitter while allowing the animal unrestrained movement in the cage. The implant can also be battery operated if desired. RF transmission is in the 8-10 MHz band, which allows the use of a simple, essentially single IC chip, receiver

    An implantable multi-channel temperature transmitter

    Get PDF
    Implantable multi-channel temperature transmitte
    corecore