318 research outputs found

    Lipotoxicity in type 2 diabetic cardiomyopathy

    Get PDF
    As obesity and type 2 diabetes are becoming an epidemic in westernized countries, the incidence and prevalence of obesity- and diabetes-related co-morbidities are increasing. In type 2 diabetes ectopic lipid accumulation in the heart has been associated with cardiac dysfunction and apoptosis, a process termed lipotoxicity. Since cardiovascular diseases are the main cause of death in diabetic patients, diagnosis and treatment become increasingly important. Although ischaemic heart disease is a major problem in diabetes, non-ischaemic heart disease (better known as diabetic cardiomyopathy) becomes increasingly important with respect to the impairment of cardiac function and mortality in type 2 diabetes. The underlying aetiology of diabetic cardiomyopathy is incompletely understood but is beginning to be elucidated. Various mechanisms have been proposed that may lead to lipotoxicity. Therefore, this review will focus on the mechanisms of cardiac lipid accumulation and its relation to the development of cardiomyopathy

    Edge-Based Color Constancy

    Full text link

    The Architecture of Happiness

    Get PDF

    Edge and corner detection by photometric quasi-invariants

    Full text link

    Geometrical models for cardiac MRI in rodents: comparison of quantification of left ventricular volumes and function by various geometrical models with a full-volume MRI data set in rodents.

    Get PDF
    van de Weijer T, van Ewijk PA, Zandbergen HR, Slenter JM, Kessels AG, Wildberger JE, Hesselink MK, Schrauwen P, Schrauwen-Hinderling VB, Kooi ME. Geometrical models for cardiac MRI in rodents: comparison of quantification of left ventricular volumes and function by various geometrical models with a full-volume MRI data set in rodents. Am J Physiol Heart Circ Physiol 302: H709-H715, 2012. First published November 18, 2011; doi:10.1152/ajpheart.00710.2011.-MRI has been proven to be an accurate method for noninvasive assessment of cardiac function. One of the current limitations of cardiac MRI is that it is time consuming. Therefore, various geometrical models are used, which can reduce scan and postprocessing time. It is unclear how appropriate their use is in rodents. Left ventricular (LV) volumes and ejection fraction (EF) were quantified based on 7.0 Tesla cine-MRI in 12 wild-type (WT) mice, 12 adipose triglyceride lipase knockout (ATGL(-/-)) mice (model of impaired cardiac function), and 11 rats in which we induced cardiac ischemia. The LV volumes and function were either assessed with parallel short-axis slices covering the full volume of the left ventricle (FV, gold standard) or with various geometrical models [modified Simpson rule (SR), biplane ellipsoid (BP), hemisphere cylinder (HC), single-plane ellipsoid (SP), and modified Teichholz Formula (TF)]. Reproducibility of the different models was tested and results were correlated with the gold standard (FV). All models and the FV data set provided reproducible results for the LV volumes and EF, with interclass correlation coefficients >= 0.87. All models significantly over-or underestimated EF, except for SR. Good correlation was found for all volumes and EF for the SR model compared with the FV data set (R-2 ranged between 0.59-0.95 for all parameters). The HC model and BP model also predicted EF well (R-2 >= 0.85), although proved to be less useful for quantitative analysis. The SP and TF models correlated poorly with the FV data set (R-2 >= 0.45 for EF and R-2 >= 0.29 for EF, respectively). For the reduction in acquisition and postprocessing time, only the SR model proved to be a valuable method for calculating LV volumes, stroke volume, and EF

    Reduced incorporation of Fatty acids into triacylglycerol in myotubes from obese individuals with type 2 diabetes.

    Get PDF
    Altered skeletal muscle lipid metabolism is a hallmark feature of type 2 (T2D). Here we investigated muscle lipid turnover in T2D versus BMI- controls and examined if putative in vivo differences would be preserved myotubes.Male obese T2D individuals (T2D) (n=6) and their BMI-matched (C) (n=6) underwent a hyperinsulinemic-euglycemic clamp, VO2max test, underwater weighing and muscle biopsy of v. lateralis. 14C-palmitate and 14C-oleate oxidation rates and incorporation into lipids were measured tissue, as well as in primary myotubes.Palmitate oxidation (C: 0.99 +/- T2D: 0.53 +/- 0.07nmol/mg protein; P=0.03) and incorporation of fatty into triacylglycerol (TAG) (C: 0.45 +/- 0.13, T2D: 0.11 +/- 0.02nmol/mg P=0.047) were significantly reduced in muscle homogenates of T2D. These reductions were not retained for palmitate oxidation in primary myotubes (P=0.38); however, incorporation of FAs into TAG was lower in T2D oleate and P=0.11 for palmitate), with a strong correlation of TAG between muscle tissue and primary myotubes (r=0.848, P=0.008).Our data that the ability to incorporate FAs into TAG is an intrinsic feature of muscle cells that is reduced in individuals with T2D

    Exercise-induced modulation of cardiac lipid content in healthy lean young men

    Get PDF
    Cardiac lipid accumulation is associated with decreased cardiac function and energy status (PCr/ATP). It has been suggested that elevated plasma fatty acid (FA) concentrations are responsible for the cardiac lipid accumulation. Therefore, the aim of the present study was to investigate if elevating plasma FA concentrations by exercise results in an increased cardiac lipid content, and if this influences cardiac function and energy status. Eleven male subjects (age 25.4 ± 1.1 years, BMI 23.6 ± 0.8 kg/m2) performed a 2-h cycling protocol, once while staying fasted and once while ingesting glucose, to create a state of high versus low plasma FA concentrations, respectively. Cardiac lipid content was measured by proton magnetic resonance spectroscopy (1H-MRS) at baseline, directly after exercise and again 4 h post-exercise, together with systolic function (by multi-slice cine-MRI) and cardiac energy status (by 31P-MRS). Plasma FA concentrations were increased threefold during exercise and ninefold during recovery in the fasted state compared with the glucose-fed state (p < 0.01). Cardiac lipid content was elevated at the end of the fasted test day (from 0.26 ± 0.04 to 0.44 ± 0.04%, p = 0.003), while it did not change with glucose supplementation (from 0.32 ± 0.03 to 0.26 ± 0.05%, p = 0.272). Furthermore, PCr/ATP was decreased by 32% in the high plasma FA state compared with the low FA state (n = 6, p = 0.014). However, in the high FA state, the ejection fraction 4 h post-exercise was higher compared with the low FA state (63 ± 2 vs. 59 ± 2%, p = 0.018). Elevated plasma FA concentrations, induced by exercise in the fasted state, lead to increased cardiac lipid content, but do not acutely hamper systolic function. Although the lower cardiac energy status is in line with a lipotoxic action of cardiac lipid content, a causal relationship cannot be proven

    Coloring local feature extraction

    Get PDF
    International audienceAlthough color is commonly experienced as an indispensable quality in describing the world around us, state-of-the art local feature-based representations are mostly based on shape description, and ignore color information. The description of color is hampered by the large amount of variations which causes the measured color values to vary significantly. In this paper we aim to extend the description of local features with color information. To accomplish a wide applicability of the color descriptor, it should be robust to : 1. photometric changes commonly encountered in the real world, 2. varying image quality, from high quality images to snap-shot photo quality and compressed internet images. Based on these requirements we derive a set of color descriptors. The set of proposed descriptors are compared by extensive testing on multiple applications areas, namely, matching, retrieval and classification, and on a wide variety of image qualities. The results show that color descriptors remain reliable under photometric and geometrical changes, and with decreasing image quality. For all experiments a combination of color and shape outperforms a pure shape-based approach
    • 

    corecore