98 research outputs found

    Orientation gradients in rapidly solidified pure aluminum thin films: comparison of experiments and phase-field crystal simulations

    Full text link
    Rapid solidification experiments on thin film aluminum samples reveal the presence of lattice orientation gradients within crystallizing grains. To study this phenomenon, a single-component phase-field crystal (PFC) model that captures the properties of solid, liquid, and vapor phases is proposed to model pure aluminium quantitatively. A coarse-grained amplitude representation of this model is used to simulate solidification in samples approaching micrometer scales. The simulations reproduce the experimentally observed orientation gradients within crystallizing grains when grown at experimentally relevant rapid quenches. We propose a causal connection between formation of defects and orientation gradients

    3D-conformal-intensity modulated radiotherapy with compensators for head and neck cancer: clinical results of normal tissue sparing

    Get PDF
    BACKGROUND: To investigate the potential of parotic gland sparing of intensity modulated radiotherapy (3D-c-IMRT) performed with metallic compensators for head and neck cancer in a clinical series by analysis of dose distributions and clinical measures. MATERIALS AND METHODS: 39 patients with squamous cell cancer of the head and neck irradiated using 3D-c-IMRT were evaluable for dose distribution within PTVs and at one parotid gland and 38 patients for toxicity analysis. 10 patients were treated primarily, 29 postoperatively, 19 received concomittant cis-platin based chemotherapy, 20 3D-c-IMRT alone. Initially the dose distribution was calculated with Helax (® )and photon fluence was modulated using metallic compensators made of tin-granulate (n = 22). Later the dose distribution was calculated with KonRad (® )and fluence was modified by MCP 96 alloy compensators (n = 17). Gross tumor/tumor bed (PTV 1) was irradiated up to 60–70 Gy, [5 fractions/week, single fraction dose: 2.0–2.2 (simultaneously integrated boost)], adjuvantly irradiated bilateral cervical lymph nodes (PTV 2) with 48–54 Gy [single dose: 1.5–1.8]). Toxicity was scored according the RTOG scale and patient-reported xerostomia questionnaire (XQ). RESULTS: Mean of the median doses at the parotid glands to be spared was 25.9 (16.3–46.8) Gy, for tin graulate 26 Gy, for MCP alloy 24.2 Gy. Tin-granulate compensators resulted in a median parotid dose above 26 Gy in 10/22, MCP 96 alloy in 0/17 patients. Following acute toxicities were seen (°0–2/3): xerostomia: 87%/13%, dysphagia: 84%/16%, mucositis: 89%/11%, dermatitis: 100%/0%. No grade 4 reaction was encountered. During therapy the XQ forms showed °0–2/3): 88%/12%. 6 months postRT chronic xerostomia °0–2/3 was observed in 85%/15% of patients, none with °4 xerostomia. CONCLUSION: 3D-c-IMRT using metallic compensators along with inverse calculation algorithm achieves sufficient parotid gland sparing in virtually all advanced head and neck cancers. Since the concept of lower single (and total) doses in the adjuvantly treated volumes reduces acute morbidity 3D-c-IMRT nicely meets demands of concurrent chemotherapy protocols

    Rotational IMRT techniques compared to fixed gantry IMRT and Tomotherapy: multi-institutional planning study for head-and-neck cases

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Recent developments enable to deliver rotational IMRT with standard C-arm gantry based linear accelerators. This upcoming treatment technique was benchmarked in a multi-center treatment planning study against static gantry IMRT and rotational IMRT based on a ring gantry for a complex parotid gland sparing head-and-neck technique.</p> <p>Methods</p> <p>Treatment plans were created for 10 patients with head-and-neck tumours (oropharynx, hypopharynx, larynx) using the following treatment planning systems (TPS) for rotational IMRT: Monaco (ELEKTA VMAT solution), Eclipse (Varian RapidArc solution) and HiArt for the helical tomotherapy (Tomotherapy). Planning of static gantry IMRT was performed with KonRad, Pinnacle and Panther DAO based on step&shoot IMRT delivery and Eclipse for sliding window IMRT. The prescribed doses for the high dose PTVs were 65.1Gy or 60.9Gy and for the low dose PTVs 55.8Gy or 52.5Gy dependend on resection status. Plan evaluation was based on target coverage, conformity and homogeneity, DVHs of OARs and the volume of normal tissue receiving more than 5Gy (V<sub>5Gy</sub>). Additionally, the cumulative monitor units (MUs) and treatment times of the different technologies were compared. All evaluation parameters were averaged over all 10 patients for each technique and planning modality.</p> <p>Results</p> <p>Depending on IMRT technique and TPS, the mean CI values of all patients ranged from 1.17 to 2.82; and mean HI values varied from 0.05 to 0.10. The mean values of the median doses of the spared parotid were 26.5Gy for RapidArc and 23Gy for VMAT, 14.1Gy for Tomo. For fixed gantry techniques 21Gy was achieved for step&shoot+KonRad, 17.0Gy for step&shoot+Panther DAO, 23.3Gy for step&shoot+Pinnacle and 18.6Gy for sliding window.</p> <p>V<sub>5Gy </sub>values were lowest for the sliding window IMRT technique (3499 ccm) and largest for RapidArc (5480 ccm). The lowest mean MU value of 408 was achieved by Panther DAO, compared to 1140 for sliding window IMRT.</p> <p>Conclusions</p> <p>All IMRT delivery technologies with their associated TPS provide plans with satisfying target coverage while at the same time respecting the defined OAR criteria. Sliding window IMRT, RapidArc and Tomo techniques resulted in better target dose homogeneity compared to VMAT and step&shoot IMRT. Rotational IMRT based on C-arm linacs and Tomotherapy seem to be advantageous with respect to OAR sparing and treatment delivery efficiency, at the cost of higher dose delivered to normal tissues. The overall treatment plan quality using Tomo seems to be better than the other TPS technology combinations.</p

    Low-lying continuum structures in B8 and Li8 in a microscopic model

    Full text link
    We search for low-lying resonances in the B8 and Li8 nuclei using a microscopic cluster model and a variational scattering method, which is analytically continued to complex energies. After fine-tuning the nucleon-nucleon interaction to get the known 1+ state of B8 at the right energy, we reproduce the known spectra of the studied nuclei. In addition, our model predicts a 1+ state at 1.3 MeV in B8, relative to the Be7+p threshold, whose corresponding pair is situated right at the Li7+n threshold in Li8. Lacking any experimental evidence for the existence of such states, it is presently uncertain whether these structures really exist or they are spurious resonances in our model. We demonstrate that the predicted state in B8, if it exists, would have important consequences for the understanding of the astrophysically important Be7(p,gamma)B8 reaction.Comment: 6 pages with 1 figure. The postscript file and more information are available at http://nova.elte.hu/~csot

    Measurement of E2 Transitions in the Coulomb Dissociation of 8B

    Full text link
    In an effort to understand the implications of Coulomb dissociation experiments for the determination of the 7Be(p,gamma)8B reaction rate, longitudinal momentum distributions of 7Be fragments produced in the Coulomb dissociation of 44 and 81 MeV/nucleon 8B beams on a Pb target were measured. These distributions are characterized by asymmetries interpreted as the result of interference between E1 and E2 transition amplitudes in the Coulomb breakup. At the lower beam energy, both the asymmetries and the measured cross sections are well reproduced by perturbation theory calculations, allowing a determination of the E2 strength.Comment: 8 pages, 3 figure

    Interatomic potentials for atomistic simulations of the Ti-Al system

    Full text link
    Semi-empirical interatomic potentials have been developed for Al, alpha-Ti, and gamma-TiAl within the embedded atomic method (EAM) by fitting to a large database of experimental as well as ab-initio data. The ab-initio calculations were performed by the linear augmented plane wave (LAPW) method within the density functional theory to obtain the equations of state for a number of crystal structures of the Ti-Al system. Some of the calculated LAPW energies were used for fitting the potentials while others for examining their quality. The potentials correctly predict the equilibrium crystal structures of the phases and accurately reproduce their basic lattice properties. The potentials are applied to calculate the energies of point defects, surfaces, planar faults in the equilibrium structures. Unlike earlier EAM potentials for the Ti-Al system, the proposed potentials provide reasonable description of the lattice thermal expansion, demonstrating their usefulness in the molecular dynamics or Monte Carlo studies at high temperatures. The energy along the tetragonal deformation path (Bain transformation) in gamma-TiAl calculated with the EAM potential is in a fairly good agreement with LAPW calculations. Equilibrium point defect concentrations in gamma-TiAl are studied using the EAM potential. It is found that antisite defects strongly dominate over vacancies at all compositions around stoichiometry, indicating that gamm-TiAl is an antisite disorder compound in agreement with experimental data.Comment: 46 pages, 6 figures (Physical Review B, in press

    Direct aperture optimization as a means of reducing the complexity of intensity modulated radiation therapy plans

    Get PDF
    Intensity Modulated Radiation Therapy (IMRT) is a means of delivering radiation therapy where the intensity of the beam is varied within the treatment field. This is done by dividing a large beam into many small beamlets. Dose constraints are assigned to both the target and sensitive structures and computerised inverse optimization is performed to find the individual weights of this large number of beamlets. The computer adjusts the intensities of these beamlets according to the required planning dose objectives. The optimized intensity patterns are then decomposed into a series of deliverable multi leaf collimator (MLC) shapes in the sequencing step

    Extrapolation of the astrophysical S factor for ^7Be(p,gamma)^8B to solar energies

    Full text link
    We investigate the energy dependence of the astrophysical SS factor for the reaction 7^7Be(p,γ)8(p,\gamma)^8B, the primary source of high-energy solar neutrinos in the solar pppp chain. Using simple models we explore the model dependence in the extrapolation of the experimental data to the region of astrophysical interest near 20 keV. We find that below approximately 400 keV the energy dependence is very well understood and constrained by the data for the elastic scattering of low energy neutrons from 7^7Li. Above 400 keV nuclear distortion of the wave function of the incident proton introduces a significant model dependence. This is particularly important for the s-wave contribution to the SS factor. The extracted value of S(0) is 19.0±1.0±0.219.0 \pm 1.0 \pm 0.2~eVb. The first error is experimental while the second is an estimate of the theoretical error in the extrapolation.Comment: 30 pages, 12 figures, 6 table

    7Be(p,gamma)8B astrophysical S-factor from precision cross section measurements

    Full text link
    We measured the 7Be(p,gamma)8B cross section from E_cm = 186 to 1200 keV, with a statistical-plus-systematic precision per point of better than +- 5%. All important systematic errors were measured including 8B backscattering losses. We obtain S_17(0) = 22.3 +- 0.7(expt) +- 0.5(theor) eV-b from our data at E_cm <= 300 keV and the theory of Descouvemont and Baye.Comment: 4 pages, 4 figure
    • …
    corecore