71 research outputs found

    Long-term safety and outcome of a temporary self-expanding metallic stent for achalasia: a prospective study with a 13-year single-center experience

    Get PDF
    To prospectively evaluate the long-term clinical safety and efficacy of a newly designed self-expanding metallic stent (SEMS) in the treatment of patients with achalasia. Seventy-five patients with achalasia were treated with a temporary SEMS with a 30-mm diameter. The SEMSs were placed under fluoroscopic guidance and removed by gastroscopy 4–5 days after stent placement. Follow-up data focused on dysphagia score, technique and clinical success, clinical remissions and failures, and complications and was performed at 6 months, 1 year, and within 3 to 5 years, 5 to 8 years, 8 to 10 years, and >10 years postoperatively. Stent placement was technically successful in all patients. Complications included stent migration (n = 4, 5.33%), chest pain (n = 28, 38.7%), reflux (n = 15, 20%), and bleeding (n = 9, 12%). No perforation or 30-day mortality occurred. Clinical success was achieved in all patients 1 month after stent removal. The overall remission rates at 6 months, 1, 1–3, 3–5, 5–8, 8–10, and >10 year follow-up periods were 100%, 96%, 93.9%, 90.9%, 100%, 100%, and 83.3%, respectively. Stent treatment failed in six patients, and the overall remission rate in our series was 92%. The median and mean primary patencies were 2.8 ± 0.28 years (95% CI: 2.25–3.35) and 4.28 ± 0.40 years (95% CI: 3.51–5.05), respectively. The use of temporary SEMSs with 30-mm diameter proved to be a safe and effective approach for managing achalasia with a long-term satisfactory clinical remission rate

    Duodenal carcinoma at the ligament of Treitz. A molecular and clinical perspective

    Get PDF
    Background There is very small occurrence of adenocarcinoma in the small bowel. We present a case of primary duodenal adenocarcinoma and discuss the findings of the case diagnostic modalities, current knowledge on the molecular biology behind small bowel neoplasms and treatment options. Case The patient had a history of iron deficiency anemia and occult bleeding with extensive workup consisting of upper endoscopy, colonoscopy, capsule endoscopy, upper gastrointestinal series with small bowel follow through and push enteroscopy. Due to persistent abdominal pain and iron deficiency anemia the patient underwent push enteroscopy which revealed adenocarcinoma of the duodenum. The patient underwent en-bloc duodenectomy which revealed T3N1M0 adenocarcinoma of the 4th portion of the duodenum. Conclusions Primary duodenal carcinoma, although rare should be considered in the differential diagnosis of occult gastrointestinal bleeding when evaluation of the lower and upper GI tract is unremarkable. We discuss the current evaluation and management of this small bowel neoplasm

    Stenting and interventional radiology for obstructive jaundice in patients with unresectable biliary tract carcinomas

    Get PDF
    Together with biliary drainage, which is an appropriate procedure for unresectable biliary cancer, biliary stent placement is used to improve symptoms associated with jaundice. Owing to investigations comparing percutaneous transhepatic biliary drainage (PTBD), surgical drainage, and endoscopic drainage, many types of stents are now available that can be placed endoscopically. The stents used are classified roughly as plastic stents and metal stents. Compared with plastic stents, metal stents are of large diameter, and have long-term patency (although they are expensive). For this reason, the use of metal stents is preferred for patients who are expected to survive for more than 6 months, whereas for patients who are likely to survive for less than 6 months, the use of plastic stents is not considered to be improper. Obstruction in a metal stent is caused by a tumor that grows within the stent through the mesh interstices. To overcome such problems, a covered metal stent was developed, and these stents are now used in patients with malignant distal biliary obstruction. However, this type of stent has been reported to have several shortcomings, such as being associated with the development of acute cholecystitis and stent migration. In spite of these shortcomings, evidence is expected to demonstrate its superiority over other types of stent

    Transanal endoscopic microsurgery versus endoscopic mucosal resection for large rectal adenomas (TREND-study)

    Get PDF
    Background: Recent non-randomized studies suggest that extended endoscopic mucosal resection (EMR) is equally effective in removing large rectal adenomas as transanal endoscopic microsurgery (TEM). If equally effective, EMR might be a more cost-effective approach as this strategy does not require expensive equipment, general anesthesia and hospital admission. Furthermore, EMR appears to be associated with fewer complications. The aim of this study is to compare the cost-effectiveness and cost-utility of TEM and EMR for the resection of large rectal adenomas. Methods/design. Multicenter randomized trial among 15 hospitals in the Netherlands. Patients with a rectal adenoma 3 cm, located between 115 cm ab ano, will be randomized to a TEM- or EMR-treatment strategy. For TEM, patients will be treated under general anesthesia, adenomas will be dissected en-bloc by a full-thickness excision, and patients will be admitted to the hospital. For EMR, no or conscious sedation is used, lesions will be resected through the submucosal plane i

    The role of capsule endoscopy in the evaluation and treatment of obscure-overt gastrointestinal bleeding during daily clinical practice: a prospective multicenter study

    No full text
    Objective. Capsule endoscopy (CE) is most commonly performed to evaluate obscure gastrointestinal bleeding (GIB). However, at present the role of CE in patients with obscure-overt GIB especially during daily clinical practice is unknown. The aim of the present study was to investigate the diagnostic yield and the impact of CE on the management of patients with obscure-overt GIB. Material and methods. Between January 2007 and December 2011 we prospectively included all patients with obscure-overt GIB who underwent CE after negative bidirectional endoscopy. CE findings revealing the cause of bleeding, type of therapeutic intervention and clinical variables associated with positive CE and recurrence of GIB were evaluated. Results. One hundred and eighteen patients with a median age of 66 years (range 8-89 years) were enrolled in the final analysis. The overall diagnostic yield of the CE was 66.9%. The most common findings were angiodysplasias (33.1%), followed by ulcer (23.7%), and tumors (6.8%). Age (p = 0.001) and cardiovascular disease (p = 0.007) were significant clinical variables predicting the higher incidence of angiodysplasias. Specific therapeutic interventions were undertaken in 54 patients with positive CE (68.4%). Recurrence of GIB was observed in one patient with negative CE (2.6%) and 16 patients with positive CE (20.3%). Univariate and multivariate analysis showed high age and no therapeutic intervention as significant factors associated with recurrent bleeding. Conclusions. CE represents a promising diagnostic method in the investigation of obscure-overt GIB, with significant impact on its clinical management in daily clinical practice
    corecore