    The In Vivo Wear Resistance of 12 Composite Resins

    Full text link
    : The in vivo wear resistance of 12 composite resins were compared with an amalgam control using the Latin Square experimental design. Sixteen edentulous patients wearing specially designed complete dentures formed the experimental population. Materials and Methods : The Michigan Computer Graphics Measurement System was used to digitize the surface of the control and composite resin samples before and after 3-month test periods to obtain wear data. The 12 composite resins selected for this investigation based on their published composite classification types were seven fine particle composites, three blends, and two microfilled composite resins. The Latin Square experimental design was found to be valid with the factor of material being statistically different at the 5% level of significance. Wear was computed as volume loss (mm 3 /mm 2 ), and all of the composites studied had more wear than the amalgam control ( P = .001). Results : After 3 months, the mean (error) of wear of the amalgam was 0.028 (0.006). Means (error) of wear for the 12 composites were ranked from most to least wear by mean wear volume loss. Conclusions : The absence of any relationship between mean wear volume loss and the volume percentage filler was confirmed by the correlation coefficient r = -0.158.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/72960/1/j.1532-849X.1992.tb00419.x.pd

    State of the science on controversial topics: missing maxillary lateral incisors--a report of the Angle Society of Europe 2012 meeting.

    Get PDF
    BACKGROUND: The optimal long-term management of the congenitally missing maxillary lateral incisor continues to cause controversy within the specialty. The Angle Society of Europe meeting 2012 dedicated a day to address some of the current controversies relating to the management of these missing lateral incisors. FINDINGS: The format of the day consisted of morning presentations and afternoon breakout sessions to discuss a variety of questions related to the management of missing lateral incisors. CONCLUSIONS: The consensus viewpoint from this day was that the care of patients with congenitally missing lateral incisors is best achieved through a multi-disciplinary approach. The current evidence base is weak, and further well-designed, prospective trials are needed

    Soft and hard tissue assessment of immediate implant placement: a case series

    Full text link
    Objectives : The aim of this prospective study was to evaluate clinically and radiographically the success and esthetic result of immediate implant placement at the time of extraction. Material and methods : Twelve patients with 14 titanium screw-shaped implants (13–16 mm length and 4.3 or 5 mm diameters) were placed in the extraction sockets. Defects after implant placement were recorded, and then filled up with deproteinized bovine bone mineral, bioabsorbable collagen membrane, and absorbable pins. The defect was again re-evaluated at second-stage surgery. Clinical and radiographic parameters of the peri-implant conditions were assessed at the moment of prosthesis placement and at 1-year follow-up. Results : The cumulative implant survival and success rate was 100% after a 1-year observation period. Analysis of the esthetic result showed that the mean pink esthetic score (PES) was 11.1 (SD 1.35) at 1-year follow-up. At 1 year, 64.3% papillae had a score of 2 and the remaining 35.7% score 3 according to the Jemt (1997) papillary index. Optimal value of width of the keratinized mucosa was recorded in 13 (92.9%) implant cases in both periods of follow-up. At 1-year follow-up, the linear distance between implant-shoulder to the bone peaks remains stable with a mean of 2.62±0.2 mm at the mesial and 2.9±0.58 mm at the distal aspect. Conclusion : Careful evaluation of potential extraction sites before immediate implant installation promotes optimal implant esthetics. To cite this article: Juodzbalys G, Wang H-L. Soft and hard tissue assessment of immediate implant placement: a case series. Clin. Oral Impl. Res. 18 , 2007; 237–243 doi:10.1111/j.1600-0501.2006.01312.xPeer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/74957/1/j.1600-0501.2006.01312.x.pd

    Clinical management and microscopic characterisation of fatique-induced failure of a dental implant. Case report

    Get PDF
    BACKGROUND: Osseointegrated endosseous implants are widely used for the rehabilitation of completely and partially edentulous patients, being the final prosthodontic treatment more predictable and the failures extremely infrequent. A case of fracture of an endosseous dental implant, replacing the maxillary first molar, occurring in a middle-age woman, 5 years after placement is reported. MATERIALS AND METHODS: The difficult management of this rare complication of implant dentistry together with the following rehabilitation is described. Additionally, the authors performed an accurate analysis of the removed fractured implant both by the stereomicroscope and by the confocal laser scanning microscope. RESULTS AND DISCUSSION: The fractured impant showed the typical signs of a fatigue-induced fracture in the coronal portion of the implant together with numerous micro-fractures in the apical one. Three dimensional imaging performed by confocal laser scanning microscope led easily to a diagnosis of "fatigue fracture" of the implant. The biomechanical mechanism of implant fractures when overstress of the implant components due to bending overload is discussed. CONCLUSION: When a fatigue-induced fracture of an dental implant occurs in presence of bending overload, the whole implant suffers a deformation that is confirmed by the alterations (micro-fractures) of the implant observable also in the osseointegrated portion that is easily appraisable by the use of stereomicroscope and confocal laser scanning microscope without preparation of the sample

    The Periotest Method: Implant-Supported Framework Precision of Fit Evaluation

    Full text link
    : In this study, the Periotest instrument was used to measure the precision of fit between cast high noble-metal frameworks and the supporting implants in a patient-simulation model. Three framework conditions and three implant-location variables were used to evaluate the rigidity of the assembly as measured by the Periotest method. The framework variables were (1) one-piece castings (OPC); (2) sectioned-soldered inaccurate castings (SSIC); and (3) sectioned-soldered accurate castings (SSAC). The implant-location variables were right anterior (RA), center (C), and left anterior (LA). Materials and Methods : The patient simulation model used consisted of three self-tapping BrÃ…nemark implants in a reasonable arch curvature in bovine bone. Three working casts were fabricated from the patient-simulation model using polyvinyl siloxane and tapered impression copings. From the working casts, three sets of three frameworks were fabricated as OPCs, SSICs, and SSACs using type 3 high noble alloy. The SSICs were fabricated with a quantitative misfit of 101.6 Îœm at the facial surface, between the abutment-to-gold cylinder interface at the C implant location. Periotest value (PTV) measurements were made at the midfacial surface of the frameworks directly above each abutment-to-gold cylinder interface. Three measurements were made for each test condition. The data were analyzed to compare framework condition(s) and implant location(s) using ANOVA and Fisher's Protected Least Significant Difference Comparison Test. Results : The ANOVA showed that significant differences exist between the mean PTV data for framework condition and for implant location (p < .01). Significant differences were shown between the mean PTV data for the SSAC assemblies and the OPC and SSIC assemblies. The SSICs displayed a more positive (+) mean PTV than the OPCs. The OPC assemblies had a more positive mean PTV than the SSAC assemblies. The mean PTV data for the SSAC assemblies had a significantly different PTV (p < .01) than the other two framework condition assemblies. The OPC and the SSIC assemblies had PTVs that were not significantly different. The C implant location was significantly different from the RA and the LA implant locations (p < .01). The RA and the LA implant locations were not significantly different from each other. The C implant location always demonstrated the most positive mean PTV regardless of the framework condition being tested. Conclusions : The Periotest instrument quantified differences in the precision of fit between three framework conditions. The SSAC assemblies were significantly more rigid than the OPC and SSIC assemblies. The OPC and SSIC assemblies' mean PTVs were not significantly different. The mean PTVs for the C implant location and the RA and LA implant locations were significantly different (p < .01). The mean PTVs of the RA and LA implant locations were not significantly different. The implant-location PTVs followed the same rank order for all three framework conditions. The procedures used to fabricate a more precise fit between the framework and the supporting implants is influenced by the skill of the clinician and technician.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/75096/1/j.1532-849X.1996.tb00298.x.pd

    Missing upper incisors: a retrospective study of orthodontic space closure versus implant

    Get PDF
    Background: The aim of this retrospective study was to compare the esthetic, periodontal, and functional outcomes of orthodontic space closure versus implant substitution in patients with missing maxillary incisors 5 years after completion of treatment. Methods: The study group consisted of ten patients treated with orthodontic space closure (six males, four females, mean age 19 ± 2.1 years at the completion of treatment) and ten patients treated with implant insertion (five males, five females, mean age 20 ± 1.4 years at the time of implant insertion). Tooth mobility, plaque index, probing depth, infraocclusion, open gingival embrasure (black triangle), and temporomandibular joint function were recorded at the 5.6 years follow-up. Self-perceived dental esthetic appearance was also evaluated through a visual analog scale (VAS) questionnaire. T-test was used to evaluate the data. Results: All patients were equally satisfied with the appearance of their teeth 5.6 ± 0.4 years after the completion of treatment. No statistically significant differences were found in relation to the VAS scores of the subjects (P < 0.857). No significant differences were found in tooth mobility, plaque index (P < 0.632), and the prevalence of signs and symptoms of temporomandibular disorders. However, significant infraocclusion was noticed in all implant patients (P < 0.001). Probing depth was also significantly higher in implant patients (P < 0.001). Conclusions: Orthodontic space closure and implant of missing maxillary incisors produced similar, well-accepted esthetic results. None of the treatments impaired temporomandibular joint function. Nevertheless, infraocclusion was evident in implant patients. Space closure patients also showed better periodontal health in comparison with implant patients
    • …