78 research outputs found

    Efficacy and patient satisfaction with autoadjusting CPAP with variable expiratory pressure vs standard CPAP: a two-night randomized crossover trial

    Get PDF
    Expiratory pressure relief (C-Flex) technology monitors the patient’s airflow during expiration and reduces the pressure in response to the patient. Increased comfort levels associated with C-Flex therapy have potential to improve patient adherence to therapy. The purpose of this study was to assess the combination of autoadjusting CPAP (APAP) and C-Flex in terms of (1) treatment efficacy, and (2) patient preference when compared to standard CPAP. Fifteen patients who had previously undergone formal CPAP titration polysomnography were treated with either one night of the APAP with C-Flex or one night of conventional CPAP, in a crossover trial. Patient satisfaction levels were recorded using visual analog scales (VAS) on the morning after the study. Mean patient age was 50 ± 12 years, body mass index (BMI) was 36 ± 6 kg/m(2), baseline AHI was 53 ± 31 events/h, and CPAP Pressure was 11 ± 2 cm/H(2)O. APAP with C-Flex was as effective as CPAP, with no differences detected in sleep latency (17 ± 5 vs 12.3 ± 3 min, p = 0.4), or respiratory indices (AHI of 4.2 ± 2 vs 2.4 ± 0.7 events/h, p = 0.1). VAS scores (scale 0–10) indicated a trend towards increased patient satisfaction while using APAP with C-Flex (7.9 vs 7.2, p = 0.07). 10 patients expressed a preference for APAP with C-Flex (VAS, 0 to10) over standard CPAP (total positive score of 68, mean score of 4.8 ± 4.3). One patient expressed no preference. Four patients expressed a preference for CPAP (total positive score of 13, mean score of 0.9 ± 1.9) (APAP with C-Flex vs standard CPAP, p < 0.01 paired t test). APAP with C-Flex eliminates sleep disordered breathing as effectively as standard CPAP. Patients indicated a preference for APAP with C-Flex suggesting a possible advantage in terms of patient adherence for this mode of treatment

    Medroxyprogesterone improves nocturnal breathing in postmenopausal women with chronic obstructive pulmonary disease

    Get PDF
    BACKGROUND: Progestins as respiratory stimulants in chronic obstructive pulmonary disease (COPD) have been investigated in males and during wakefulness. However, sleep and gender may influence therapeutic responses. We investigated the effects of a 2-week medroxyprogesterone acetate (MPA) therapy on sleep and nocturnal breathing in postmenopausal women. METHODS: A single-blind placebo-controlled trial was performed in 15 postmenopausal women with moderate to severe COPD. A 12-week trial included 2-week treatment periods with placebo and MPA (60 mg/d/14 days). All patients underwent a polysomnography with monitoring of SaO(2 )and transcutaneous PCO(2 )(tcCO(2)) at baseline, with placebo, with medroxyprogesterone acetate (MPA 60 mg/d/14 days), and three and six weeks after cessation of MPA. RESULTS: Thirteen patients completed the trial. At baseline, the average ± SD of SaO(2 )mean was 90.6 ± 3.2 % and the median of SaO(2 )nadir 84.8 % (interquartile range, IQR 6.1). MPA improved them by 1.7 ± 1.6 %-units (95 % confidence interval (CI) 0.56, 2.8) and by 3.9 %-units (IQR 4.9; 95% CI 0.24, 10.2), respectively. The average of tcCO(2 )median was 6.0 ± 0.9 kPa and decreased with MPA by 0.9 ± 0.5 kPa (95% CI -1.3, -0.54). MPA improved SaO(2 )nadir and tcCO(2 )median also during REM sleep. Three weeks after cessation of MPA, the SaO(2 )mean remained 1.4 ± 1.8 %-units higher than at baseline, the difference being not significant (95% CI -0.03, 2.8). SaO(2 )nadir was 2.7 %-units (IQR 4.9; 95% CI 0.06, 18.7) higher than at baseline. Increases in SaO(2 )mean and SaO(2 )nadir during sleep with MPA were inversely associated with baseline SaO(2 )mean (r = -0.70, p = 0.032) and baseline SaO(2 )nadir (r = -0.77, p = 0.008), respectively. Treatment response in SaO(2 )mean, SaO(2 )nadir and tcCO(2 )levels did not associate with pack-years smoked, age, BMI, spirometric results or sleep variables. CONCLUSION: MPA-induced respiratory improvement in postmenopausal women seems to be consistent and prolonged. The improvement was greater in patients with lower baseline SaO(2 )values. Long-term studies in females are warranted

    Reliability of home CPAP titration with different automatic CPAP devices

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>CPAP titration may be completed by automatic apparatus. However, differences in pressure behaviour could interfere with the reliability of pressure recommendations. Our objective was to compare pressure behaviour and effective pressure recommendations between three Automatic CPAP machines (Autoset Spirit, Remstar Auto, GK 420).</p> <p>Methods</p> <p>Sixteen untreated obstructive sleep apnea patients were randomly allocated to one of the 3 tested machines for a one-week home titration trial in a crossover design with a 10 days washout period between trials.</p> <p>Results</p> <p>The median pressure value was significantly lower with machine GK 420 (5.9 +/- 1.8 cm H<sub>2</sub>O) than with the other devices both after one night and one week of CPAP titration (7.4 +/- 1.3 and 6.6 +/- 1.9 cm H<sub>2</sub>O). The maximal pressure obtained over the one-week titration was significantly higher with Remstar Auto (12.6 +/- 2.4 cm H<sub>2</sub>O, Mean +/- SD) than with the two other ones (10.9 +/- 1.0 and 11.0 +/- 2.4 cm H<sub>2</sub>O). The variance in pressure recommendation significantly differed between the three machines after one night and between Autoset Spirit and the two other machines after 1 week.</p> <p>Conclusion</p> <p>Pressure behaviour and pressure recommendation significantly differ between Auto CPAP machines both after one night and one week of home titration.</p

    Phosphorescent Energy Downshifting for Diminishing Surface Recombination in Silicon Nanowire Solar Cells

    Get PDF
    Molecularly engineered Ir(III) complexes can transfer energy from short-wavelength photons (lambda &lt; 450 nm) to photons of longer wavelength (lambda &gt; 500 nm), which can enhance the otherwise low internal quantum efficiency (IQE) of crystalline Si (c-Si) nanowire solar cells (NWSCs) in the shortwavelength region. Herein, we demonstrate a phosphorescent energy downshifting system using Ir(III) complexes at short wavelengths (300-450 nm) to diminish the severe surface recombination that occurs in c-Si NWSCs. The developed Ir(III) complexes can be considered promising energy converters because they exhibit superior intrinsic properties such as a high quantum yield, a large Stokes shift, a long exciton diffusion length in crystalline film, and a reproducible synthetic procedure. Using the developed 1011) complexes, highly crystalline energy downshifting layers were fabricated by ultrasonic spray deposition to enhance the photoluminescence efficiency by increasing the radiative decay. With the optimized energy downshifting layer, our 1cm(2) c-Si NWSCs with Ir(III) complexes exhibited a higher IQE value for short-wavelength light (300-450 nm) compared with that of bare Si NWSCs without Ir(III) complexes, resulting in a notable increase in the short-circuit current density (from 34.4 mA.cm(-2) to 36.5 mA.cm(-2) )

    Predictors of 1-year compliance with adaptive servoventilation in patients with heart failure and sleep disordered breathing: preliminary data from the ADVENT-HF trial

    Get PDF
    Despite its effectiveness in suppressing sleep disordered breathing (SDB), positive airway pressure therapy (PAP) is not always well tolerated by patients and long-term adherence can be problematic. Recently, two multicentre, randomised clinical trials (RCTs) tested the effects of PAP for patients with cardiovascular disease and co-existing SDB on morbidity and mortality with negative outcomes [1, 2]. Relatively poor adherence to PAP therapy (mean 3.7 and 3.3 h·day-1, respectively) in these two trials might have contributed to their poor results. Indeed, higher PAP use per day is associated with better clinical outcomes than lower use [3]

    Does CPAP delay the development of cardiovascular disease in patients with obstructive sleep apnoea hypopnoea?

    No full text
    Large, long term, randomised clinical trials are needed to establish whether CPAP treatment of patients with OSAH has a cardiovascular benefi
    corecore