531 research outputs found

    Chronic pseudoaneurysm of the left ventricle

    Get PDF
    We present a case of a 55-year-old men who suffered a silent myocardial infarction four years earlier and presented with exertional dyspnoea. Cardiac magnetic resonance imaging (CMR) and Multislice computed tomography (MSCT) was performed and revealed a giant pseudoaneursym of the lateral wall of the left ventricle with the presence of a thrombus in the lateral wall of the pseudoaneursym. We present this case since excellent non-invasive evaluation of the pseudoaneursym was feasible using state-of-the-art imaging modalities. Information on left ventricular geometry and function as well as myocardial viability and coronary anatomy is available when both MSCT and CMR are performed. This combined approach of these two imaging modalities provide clinically relevant information and may guide therapeutic decision making

    Disappearance of Spontaneous Echographic Contrast after Balloon Mitral Valvuloplasty: An Indicator of Sustained Hemodynamic Improvement

    Get PDF
    In three patients undergoing mitral balloon valvuloplasty for mitral stenosis transesophageal echocardiography was performed before, immediately after, and 6 months after the procedure. In the one patient with persistent hemodynamically favorable result, the spontaneous echocardiographic contrast, which was seen in all three preoperatively, did not recur; in the other two patients the phenomenon was observed again after 6 months. We conclude that the disappearance of spontaneous echocardiographic contrast might be a functional morphological measure of sustained hemodynamic improvement after balloon mitral valvuloplasty. Copyrigh

    Adjustment method for mechanical Boston scientific corporation 30 MHz intravascular ultrasound catheters connected to a Clearview console. Mechanical 30 MHz IVUS catheter adjustment.

    Get PDF
    Intracoronary ultrasound (ICUS) is often used in studies evaluating new interventional techniques. It is important that quantitative measurements performed with various ICUS imaging equipment and materials are comparable. During evaluation of quantitative coronary ultrasound (QCU) software, it appeared that Boston Scientific Corporation (BSC) 30 MHz catheters connected to a Clearview ultrasound console showed smaller dimensions of an in vitro phantom model than expected. In cooperation with the manufacturer the cause of this underestimation was determined, which is described in this paper, and the QCU software was extended with an adjustment. Evaluation was performed by performing in vitro measurements on a phantom model consisting of four highly accurate steel rings (perfect reflectors) with diameters of 2, 3, 4 and 5 mm. Relative differences (unadjusted) of the phantom were respectively: 15.92, 13.01, 10.10 and 12.23%. After applying the adjustment: -0.96, -1.84, -1.35 and -1.43%. In vivo measurements were performed on 24 randomly selected ICUS studies. These showed differences for not adjusted vs. adjusted measurements of lumen-, vessel- and plaque volumes of -10.1 +/- 1.5, -6.7 +/- 0.9 and -4.4 +/- 0.6%. An off-line adjustment formula was derived and applied on previous numerical QCU output data showing relative differences for lumen- and vessel volumes of 0.36 +/- 0.51 and 0.13 +/- 0.31%. 30 MHz BSC catheters connected to a Clearview ultrasound console underestimate vessel dimensions. This can retrospectively be adjusted within QCU software as well as retrospectively on numerical QCU data using a mathematical model

    Atherosclerotic coronary lesions with inadequate compensatory enlargement have smaller plaque and vessel volumes: observations with three dimensional intravascular ultrasound in vivo.

    Get PDF
    OBJECTIVE: To compare vessel, lumen, and plaque volumes in atherosclerotic coronary lesions with inadequate compensatory enlargement versus lesions with adequate compensatory enlargement. DESIGN: 35 angiographically significant coronary lesions were examined by intravascular ultrasound (IVUS) during motorised transducer pullback. Segments 20 mm in length were analysed using a validated automated three dimensional analysis system. IVUS was used to classify les

    Acute ST segment elevation during exercise stress echocardiography due to severe pulmonary hypertension

    Get PDF
    A 51-year-old female undergoing an outpatient stress echocardiogram to evaluate atypical chest pain developed acute ST elevation in the anterior precordial leads on electrocardiogram following exercise. Echocardiography revealed a severe rise in pulmonary artery systolic pressure (PASP) with marked right ventricular (RV) enlargement and interventricular septum flattening. Subsequently, cardiac catherization confirmed an exercise-induced elevation in PASP and diagnosed pulmonary arterial hypertension without evidence of coronary artery disease. This case suggests that an acute elevation in pulmonary artery pressure with RV dilation may be a potential cause of acute ST elevation during stress testing

    Recovery of left ventricular function after primary angioplasty for acute myocardial infarction.

    Get PDF
    AIMS: To study recovery of segmental wall thickening (SWT), ejection fraction (EF), and end-systolic volume (ESV) after acute myocardial infarction (AMI) in patients who underwent primary stenting with drug-eluting stents. Additionally, to evaluate the predictive value of magnetic resonance imaging (MRI)-based myocardial perfusion and delayed enhancement (DE) imaging. METHODS AND RESULTS: Twenty-two patients underwent cine-MRI, first-pass perfusion, and DE imaging 5 days after successful placement of a drug-eluting stent in the infarct-related coronary artery. Regional myocardial perfusion and the transmural extent of DE were evaluated. A per patient perfusion score was calculated and consisted of a summation of all segmental scores. Myocardial infarct size was quantified by measuring the volume of DE. At 5 months after AMI, cine-MRI was performed and SWT, EF, and ESV were quantified. EF increased from 48+/-11 to 55+/-9% (P<0.01). SWT at 5 months was inversely related to baseline segmental DE scores (P<0.001) and segmental perfusion scores (P<0.001). EF and ESV at 5 months were related to acute infarct size (R(2)=0.65; P<0.001 and R(2)=0.78; P<0.001, respectively) and the calculated perfusion score (R(2)=0.23; P=0.02 and R(2)=0.14; P=0.09, respectively) at baseline. CONCLUSION: Marked recovery of left ventricular function was observed in patients receiving a drug-eluting stent for AMI. DE imaging appears to be a better prognosticator than perfusion imaging

    Small coronary calcifications are not detectable by 64-slice contrast enhanced computed tomography

    Get PDF
    Recently, small calcifications have been associated with unstable plaques. Plaque calcifications are both in intravascular ultrasound (IVUS) and multi-slice computed tomography (MSCT) easily recognized. However, smaller calcifications might be missed on MSCT due to its lower resolution. Because it is unknown to which extent calcifications can be detected with MSCT, we compared calcification detection on contrast enhanced MSCT with IVUS. The coronary arteries of patients with myocardial infarction or unstable angina were imaged by 64-slice MSCT angiography and IVUS. The IVUS and MSCT images were registered and the arteries were inspected on the presence of calcifications on both modalities independently. We measured the length and the maximum circumferential angle of each calcification on IVUS. In 31 arteries, we found 99 calcifications on IVUS, of which only 47 were also detected on MSCT. The calcifications missed on MSCT (nĀ =Ā 52) were significantly smaller in angle (27Ā°Ā Ā±Ā 16Ā° vs. 59Ā°Ā Ā±Ā 31Ā°) and length (1.4Ā Ā±Ā 0.8 vs. 3.7Ā Ā±Ā 2.2Ā mm) than those detected on MSCT. Calcifications could only be detected reliably on MSCT if they were larger than 2.1Ā mm in length or 36Ā° in angle. Half of the calcifications seen on the IVUS images cannot be detected on contrast enhanced 64-slice MSCT angiography images because of their size. The limited resolution of MSCT is the main reason for missing small calcifications

    Short- and long-term clinical benefit of sirolimus-eluting stents compared to conventional bare stents for patients with acute myocardial infarction

    Get PDF
    AbstractObjectivesThis study investigated the clinical outcomes of patients with ST-segment elevation myocardial infarction (MI) treated with sirolimus-eluting stents (SESs) or with conventional bare stents.BackgroundThe clinical impact of SES implantation for patients with ST-segment elevation MI is currently unknown.MethodsPrimary angioplasty was performed with SESs in 186 consecutive patients with acute MI who were compared with 183 patients treated with bare stents. The incidence of death, reinfarction, and repeat revascularization was assessed at 30 and 300 days.ResultsPostprocedure vessel patency, enzymatic release, and the incidence of short-term adverse events were similar in both the sirolimus and the bare stents (30-day rate of death, reinfarction, or repeat revascularization: 7.5% vs. 10.4%, respectively; p = 0.4). Stent thrombosis was not diagnosed in any patient in the sirolimus group and occurred in 1.6% of patients treated with bare stents (p = 0.1). At 300 days, treatment with SESs significantly reduced the incidence of combined adverse events (9.4% vs. 17%; hazard ratio [HR] 0.52 [95% confidence interval (CI) 0.30 to 0.92]; p = 0.02), mainly due to a marked reduction in the risk of repeat intervention (1.1% vs. 8.2%; HR 0.21 [95% CI 0.06 to 0.74]; p = 0.01).ConclusionsCompared to conventional bare stents, the SESs were not associated with an increased risk of stent thrombosis and were effective in reducing the incidence of adverse events at 300 days in unselected patients with ST-segment elevation acute MI referred for primary angioplasty
    • ā€¦
    corecore