58 research outputs found
Integrated impedance bridge for absolute capacitance measurements at cryogenic temperatures and finite magnetic fields
We developed an impedance bridge that operates at cryogenic temperatures
(down to 60 mK) and in perpendicular magnetic fields up to at least 12 T. This
is achieved by mounting a GaAs HEMT amplifier perpendicular to a printed
circuit board containing the device under test and thereby parallel to the
magnetic field. The measured amplitude and phase of the output signal allows
for the separation of the total impedance into an absolute capacitance and a
resistance. Through a detailed noise characterization, we find that the best
resolution is obtained when operating the HEMT amplifier at the highest gain.
We obtained a resolution in the absolute capacitance of
6.4~aF at 77 K on a comb-drive actuator, while maintaining
a small excitation amplitude of 15~. We show the magnetic field
functionality of our impedance bridge by measuring the quantum Hall plateaus of
a top-gated hBN/graphene/hBN heterostructure at 60~mK with a probe signal of
12.8~.Comment: 7 pages, 5 figure
Identification and quantification of microplastics in wastewater using focal plane array-based reflectance micro-FT-IR imaging
Microplastics (<5 mm) have been documented in environmental samples on a global scale. While these pollutants may enter aquatic environments via wastewater treatment facilities, the abundance of microplastics in these matrices has not been investigated. Although efficient methods for the analysis of microplastics in sediment samples and marine organisms have been published, no methods have been developed for detecting these pollutants within organic-rich wastewater samples. In addition, there is no standardized method for analyzing microplastics isolated from environmental samples. In many cases, part of the identification protocol relies on visual selection before analysis, which is open to bias. In order to address this, a new method for the analysis of microplastics in wastewater was developed. A pretreatment step using 30% hydrogen peroxide (H2O2) was employed to remove biogenic material, and focal plane array (FPA)-based reflectance micro-Fourier-transform (FT-IR) imaging was shown to successfully image and identify different microplastic types (polyethylene, polypropylene, nylon-6, polyvinyl chloride, polystyrene). Microplastic-spiked wastewater samples were used to validate the methodology, resulting in a robust protocol which was nonselective and reproducible (the overall success identification rate was 98.33%). The use of FPA-based micro-FT-IR spectroscopy also provides a considerable reduction in analysis time compared with previous methods, since samples that could take several days to be mapped using a single-element detector can now be imaged in less than 9 h (circular filter with a diameter of 47 mm). This method for identifying and quantifying microplastics in wastewater is likely to provide an essential tool for further research into the pathways by which microplastics enter the environment.This work is funded by a NERC (Natural Environment Research Council) CASE studentship (NE/K007521/1) with contribution from industrial partner Fera Science Ltd., United Kingdom. The authors would like to thank Peter Vale, from Severn Trent Water Ltd, for providing access to and additionally Ashley Howkins (Brunel University London) for providing travel and assistance with the sampling of the Severn Trent wastewater treatment plant in Derbyshire, UK. We are grateful to Emma Bradley and Chris Sinclair for providing helpful suggestions for our research
High quality RNA isolation from Aedes aegypti midguts using laser microdissection microscopy
Background: Laser microdissection microscopy (LMM) has potential as a research tool because it allows precise excision of target tissues or cells from a complex biological specimen, and facilitates tissue-specific sample preparation. However, this method has not been used in mosquito vectors to date. To this end, we have developed an LMM method to isolate midgut RNA using Aedes aegypti
Pre-processing Agilent microarray data
<p>Abstract</p> <p>Background</p> <p>Pre-processing methods for two-sample long oligonucleotide arrays, specifically the Agilent technology, have not been extensively studied. The goal of this study is to quantify some of the sources of error that affect measurement of expression using Agilent arrays and to compare Agilent's Feature Extraction software with pre-processing methods that have become the standard for normalization of cDNA arrays. These include log transformation followed by loess normalization with or without background subtraction and often a between array scale normalization procedure. The larger goal is to define best study design and pre-processing practices for Agilent arrays, and we offer some suggestions.</p> <p>Results</p> <p>Simple loess normalization without background subtraction produced the lowest variability. However, without background subtraction, fold changes were biased towards zero, particularly at low intensities. ROC analysis of a spike-in experiment showed that differentially expressed genes are most reliably detected when background is not subtracted. Loess normalization and no background subtraction yielded an AUC of 99.7% compared with 88.8% for Agilent processed fold changes. All methods performed well when error was taken into account by t- or z-statistics, AUCs ≥ 99.8%. A substantial proportion of genes showed dye effects, 43% (99%<it>CI </it>: 39%, 47%). However, these effects were generally small regardless of the pre-processing method.</p> <p>Conclusion</p> <p>Simple loess normalization without background subtraction resulted in low variance fold changes that more reliably ranked gene expression than the other methods. While t-statistics and other measures that take variation into account, including Agilent's z-statistic, can also be used to reliably select differentially expressed genes, fold changes are a standard measure of differential expression for exploratory work, cross platform comparison, and biological interpretation and can not be entirely replaced. Although dye effects are small for most genes, many array features are affected. Therefore, an experimental design that incorporates dye swaps or a common reference could be valuable.</p
Aroma‐volatile profile and its changes in Australian grown black Périgord truffle ( Tuber melanosporum
- …
