13 research outputs found

    Estimating the Reduction in the Radiation Burden From Nuclear Cardiology Through Use of Stress-Only Imaging in the United States and Worldwide

    Get PDF
    Not availabl

    Comparison of Radiation Doses and Best-Practice Use for Myocardial Perfusion Imaging in US and Non-US Laboratories: Findings From the IAEA (International Atomic Energy Agency) Nuclear Cardiology Protocols Study

    Get PDF
    not availabl

    Nuclear cardiology practice and associated radiation doses in Europe: results of the IAEA Nuclear Cardiology Protocols Study (INCAPS) for the 27 European countries

    Get PDF
    Purpose: Nuclear cardiology is widely used to diagnose coronary artery disease and to guide patient management, but data on current practices, radiation dose-related best practices, and radiation doses are scarce. To address these issues, the IAEA conducted a worldwide study of nuclear cardiology practice. We present the European subanalysis. Methods: In March 2013, the IAEA invited laboratories across the world to document all SPECT and PET studies performed in one week. The data included age, gender, weight, radiopharmaceuticals, injected activities, camera type, positioning, hardware and software. Radiation effective dose was calculated for each patient. A quality score was defined for each laboratory as the number followed of eight predefined best practices with a bearing on radiation exposure (range of quality score 0 – 8). The participating European countries were assigned to regions (North, East, South, and West). Comparisons were performed between the four European regions and between Europe and the rest-of-the-world (RoW). Results: Data on 2,381 European patients undergoing nuclear cardiology procedures in 102 laboratories in 27 countries were collected. A cardiac SPECT study was performed in 97.9 % of the patients, and a PET study in 2.1 %. The average effective dose of SPECT was 8.0 ± 3.4 mSv (RoW 11.4 ± 4.3 mSv; P < 0.001) and of PET was 2.6 ± 1.5 mSv (RoW 3.8 ± 2.5 mSv; P < 0.001). The mean effective doses of SPECT and PET differed between European regions (P < 0.001 and P = 0.002, respectively). The mean quality score was 6.2 ± 1.2, which was higher than the RoW score (5.0 ± 1.1; P < 0.001). Adherence to best practices did not differ significantly among the European regions (range 6 to 6.4; P = 0.73). Of the best practices, stress-only imaging and weight-adjusted dosing were the least commonly used. Conclusion: In Europe, the mean effective dose from nuclear cardiology is lower and the average quality score is higher than in the RoW. There is regional variation in effective dose in relation to the best practice quality score. A possible reason for the differences between Europe and the RoW could be the safety culture fostered by actions under the Euratom directives and the implementation of diagnostic reference levels. Stress-only imaging and weight-adjusted activity might be targets for optimization of European nuclear cardiology practice

    Current worldwide nuclear cardiology practices andradiationexposure: results from the 65 country IAEA nuclear cardiology protocols cross-sectional study (INCAPS)

    Get PDF
    Aims To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiationoptimizing 'best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. Methods and results We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight 'best practices' relating to radiation exposurewere identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more 'best practices' had lower EDs Conclusion Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally

    Nuclear cardiology practice in Asia: Analysis of radiation exposure and best practice for myocardial perfusion imaging ― results from the IAEA nuclear cardiology protocols cross-sectional study (INCAPS) ―

    No full text
    Background: This paper examines the current status of radiation exposure to patients in myocardial perfusion imaging (MPI) in Asia. Methods and Results: Laboratories voluntarily provided information on MPI performed over a 1-week period. Eight best practice criteria regarding MPI were predefined by an expert panel. Implementation of ≥6 best practices (quality index [QI] ≥6) was pre-specified as a desirable goal for keeping radiation exposure at a low level. Radiation effective dose (ED) in 1,469 patients and QI of 69 laboratories in Asia were compared against data from 239 laboratories in the rest of the world (RoW). Mean ED was significantly higher in Asia (11.4 vs. 9.6 mSv; P<0.0001), with significantly lower doses in South-East vs. East Asia (9.7 vs. 12.7 mSv; P<0.0001). QI in Asia was lower than in RoW. In comparison with RoW, Asian laboratories used thallium more frequently, used weight-based technetium dosing less frequently, and trended towards a lower rate of stress-only imaging. Conclusions: MPI radiation dose in Asia is higher than that in the RoW and linked to less consistent use of laboratory best practices such as avoidance of thallium, weight-based dosing, and use of stress-only imaging. Given that MPI is performed in Asia within a diverse array of medical contexts, laboratory-specific adoption of best practices offers numerous opportunities to improve quality of care

    Nuclear Cardiology Practices and Radiation Exposure in the Oceania Region: Results From the IAEA Nuclear Cardiology Protocols Study (INCAPS)

    No full text
    Background There is concern about radiation exposure with radionuclide myocardial perfusion imaging (MPI). This sub-study of the International Atomic Energy Agency (IAEA) Nuclear Cardiology Protocols Study reports radiation doses from MPI, and use of dose-optimisation protocols in Australia and New Zealand (ANZ), and compares them with data from the rest of the world. Methods Data were collected from 7911 MPI studies performed in 308 laboratories worldwide in one week in 2013, including 439 MPI studies from 34 ANZ laboratories. For each laboratory, effective radiation dose (ED) and a quality index (QI) score (out of 8) based on pre-specified “best practices” was determined. Results In ANZ patients, ED ranged from 0.9-17.9 milliSievert (mSv). Median ED was similar in ANZ compared with the rest of the world (10.0 (IQR: 6.5-11.7) vs. 10.0 (IQR 6.4-12.6, P=0.15), as were mean QI scores (5.5±0.7 vs. 5.4±1.3, P=0.84). Use of stress-only imaging (17.6% vs. 31.8% of labs, P=0.09) and weight-based dosing of technetium-99m (14.7% vs. 30.3%, P=0.07) was lower in ANZ compared with the rest of the world but this difference was not statistically significant. Median ED was significantly lower in metropolitan versus non-metropolitan laboratories (10.1 mSv vs. 11.6 mSv, P<0.01), although mean QI scores were similar (5.4±0.8 vs. 5.5±0.7, P=0.75). Conclusion Across ANZ, there is variability in ED from MPI, and use of radiation safety practices, particularly between metropolitan and non-metropolitan laboratories. Overall, ANZ laboratories have a similar median ED to laboratories in the rest of the world

    Gender Differences in Radiation Dose from Nuclear Cardiology Studies Across the World Findings from the INCAPS Registry

    Get PDF
    Objectives The aim of this study was to investigate gender-based differences in nuclear cardiology practice globally, with a particular focus on laboratory volume, radiation dose, protocols, and best practices. Background It is unclear whether gender-based differences exist in radiation exposure for nuclear cardiology procedures. Methods In a large, multicenter, observational, cross-sectional study encompassing 7,911 patients in 65 countries, radiation effective dose was estimated for each examination. Patient-level best practices relating to radiation exposure were compared between genders. Analysis of covariance was used to determine any difference in radiation exposure according to gender, region, and the interaction between gender and region. Linear, logistic, and hierarchical regression models were developed to evaluate gender-based differences in radiation exposure and laboratory adherence to best practices. The study also included the United Nations Gender Inequality Index and Human Development Index as covariates in multivariable models. Results The proportion of myocardial perfusion imaging studies performed in women varied among countries; however, there was no significant correlation with the Gender Inequality Index. Globally, mean effective dose for nuclear cardiology procedures was only slightly lower in women (9.6 ± 4.5 mSv) than in men (10.3 ± 4.5 mSv; p < 0.001), with a difference of only 0.3 mSv in a multivariable model adjusting for patients' age and weight. Stress-only imaging was performed more frequently in women (12.5% vs. 8.4%; p < 0.001); however, camera-based dose reduction strategies were used less frequently in women (58.6% vs. 65.5%; p < 0.001). Conclusions Despite significant worldwide variation in best practice use and radiation doses from nuclear cardiology procedures, only small differences were observed between genders worldwide. Regional variations noted in myocardial perfusion imaging use and radiation dose offer potential opportunities to address gender-related differences in delivery of nuclear cardiology care

    Nuclear cardiology practices and radiation exposure in Africa: Results from the IAEA Nuclear Cardiology Protocols Study (INCAPS)

    Get PDF
    Objective: While nuclear myocardial perfusion imaging (MPI) offers many benefits to patients with known or suspected cardiovascular disease, concerns exist regarding radiationassociated health effects. Little is known regarding MPI practice in Africa. We sought to characterise radiation doses and the use of MPI best practices that could minimise radiation in African nuclear cardiology laboratories, and compare these to practice worldwide. Methods: Demographics and clinical characteristics were collected for a consecutive sample of 348 patients from 12 laboratories in six African countries over a one-week period from March to April 2013. Radiation effective dose (ED) was estimated for each patient. A quality index (QI) enumerating adherence to eight best practices, identified a priori by an IAEA expert panel, was calculated for each laboratory. We compared these metrics with those from 7 563 patients from 296 laboratories outside Africa. Results: Median (interquartile range) patient ED in Africa was similar to that of the rest of the world [9.1 (5.1-15.6) vs 10.3 mSv (6.8-12.6), p = 0.14], although a larger proportion of African patients received a low ED, ≤ 9 mSv targeted in societal recommendations (49.7 vs 38.2%, p < 0.001). Bestpractice adherence was higher among African laboratories (QI score: 6.3 ± 1.2 vs 5.4 ± 1.3, p = 0.013). However, median ED varied significantly among African laboratories (range: 2.0-16.3 mSv; p < 0.0001) and QI range was 4-8. Conclusion: Patient radiation dose from MPI in Africa was similar to that in the rest of the world, and adherence to best practices was relatively high in African laboratories. Nevertheless there remain opportunities to further reduce radiation exposure to African patients from MPI

    Nuclear cardiology practices and radiation exposure in Africa: Results from the IAEA Nuclear Cardiology Protocols Study (INCAPS)

    No full text
    Objective: While nuclear myocardial perfusion imaging (MPI) offers many benefits to patients with known or suspected cardiovascular disease, concerns exist regarding radiationassociated health effects. Little is known regarding MPI practice in Africa. We sought to characterise radiation doses and the use of MPI best practices that could minimise radiation in African nuclear cardiology laboratories, and compare these to practice worldwide. Methods: Demographics and clinical characteristics were collected for a consecutive sample of 348 patients from 12 laboratories in six African countries over a one-week period from March to April 2013. Radiation effective dose (ED) was estimated for each patient. A quality index (QI) enumerating adherence to eight best practices, identified a priori by an IAEA expert panel, was calculated for each laboratory. We compared these metrics with those from 7 563 patients from 296 laboratories outside Africa. Results: Median (interquartile range) patient ED in Africa was similar to that of the rest of the world [9.1 (5.1-15.6) vs 10.3 mSv (6.8-12.6), p = 0.14], although a larger proportion of African patients received a low ED, ≤ 9 mSv targeted in societal recommendations (49.7 vs 38.2%, p < 0.001). Bestpractice adherence was higher among African laboratories (QI score: 6.3 ± 1.2 vs 5.4 ± 1.3, p = 0.013). However, median ED varied significantly among African laboratories (range: 2.0-16.3 mSv; p < 0.0001) and QI range was 4-8. Conclusion: Patient radiation dose from MPI in Africa was similar to that in the rest of the world, and adherence to best practices was relatively high in African laboratories. Nevertheless there remain opportunities to further reduce radiation exposure to African patients from MPI

    Opportunities for improvement on current nuclear cardiology practices and radiation exposure in Latin America: Findings from the 65-country IAEA Nuclear Cardiology Protocols cross-sectional Study (INCAPS)

    No full text
    Background: Comparison of Latin American (LA) nuclear cardiology (NC) practice with that in the rest of the world (RoW) will identify areas for improvement and lead to educational activities to reduce radiation exposure from NC. Methods and Results: INCAPS collected data on all SPECT and PET procedures performed during a single week in March-April 2013 in 36 laboratories in 10 LA countries (n = 1139), and 272 laboratories in 55 countries in RoW (n = 6772). Eight “best practices” were identified a priori and a radiation-related Quality Index (QI) was devised indicating the number used. Mean radiation effective dose (ED) in LA was higher than in RoW (11.8 vs 9.1 mSv, p < 0.001). Within a populous country like Brazil, a wide variation in laboratory mean ED was found, ranging from 8.4 to 17.8 mSv. Only 11% of LA laboratories achieved median ED <9 mSv, compared to 32% in RoW (p < 0.001). QIs ranged from 2 in a laboratory in Mexico to 7 in a laboratory in Cuba. Three major opportunities to reduce ED for LA patients were identified: (1) more laboratories could implement stress-only imaging, (2) camera-based methods of ED reduction, including prone imaging, could be more frequently used, and (3) injected activity of 99mTc could be adjusted reflecting patient weight/habitus. Conclusions: On average, radiation dose from NC is higher in LA compared to RoW, with median laboratory ED <9 mSv achieved only one third as frequently as in RoW. Opportunities to reduce radiation exposure in LA have been identified and guideline-based recommendations made to optimize protocols and adhere to the “as low as reasonably achievable” (ALARA) principle
    corecore