162 research outputs found

    Comparison of the acute outcome of two cryoballoon technologies for pulmonary vein isolation:An updated systematic review and meta-analysis

    Get PDF
    Initial experience suggests that the POLARx cryoballoon system (Boston Scientific) has a similar procedural efficacy and safety as Arctic Front Advance Pro (AFA-Pro, Medtronic). We performed an updated systematic review and meta-analysis comparing POLARx and AFA-Pro. Embase, MEDLINE, Web of Science, Cochrane, and Google Scholar databases were searched until 12/01/2022 for studies comparing POLARx versus AFA-Pro in patients undergoing pulmonary vein (PV) isolation for AF. A total of 8 studies, involving 1146 patients from 11 European centers were included (POLARx n = 317; AFA-Pro n = 819). There were no differences in acute PV isolation, procedure time, fluoroscopy time, ablation time, minimal esophageal temperature, and risk of phrenic nerve palsy or thromboembolic events. Balloon nadir temperatures were lower for POLARx in all PVs. Compared with AFA-Pro, POLARx had a higher rate of first freeze isolation in the left inferior PV (LIPV) (odds ratio [OR]: 2.60; 95 % confidence interval [CI]: 1.06 to 6.43; P = 0.04), higher likelihood of time-to-isolation (TTI) recording in LIPV (OR: 2.91; 95 % CI: 1.54 to 5.49; P = 0.001) and right inferior PV (OR: 3.23; 95 % CI: 1.35 to 7.74; P = 0.008). In contrast, the TTI in LIPV was longer with POLARx in comparison to AFA-Pro (mean difference: 7.61 sec; 95 % CI 2.43 to 12.8 sec; P = 0.004). In conclusion, POLARx and AFA-Pro have a similar acute outcome. Interestingly, there was a higher rate of TTI recording in the inferior PVs with POLARx. This updated meta-analysis provides new safety data on esophageal temperature and thromboembolic events

    Genetic variants of VDR and CYP2R1 affect BMI independently of serum vitamin D concentrations

    Get PDF
    BACKGROUND: Vitamin D metabolism and obesity have been linked by several studies, however the reason for this association is unclear. Our objective was to investigate potential correlations between genetic variants in key enzymes of vitamin D metabolism and the body mass index on a representative and random sample of Hungarian adults. METHODS: Altogether 462 severely vitamin D deficient individuals were studied at the end of winter in order to decrease environmental and maximize any relevant genetic effect. Furthermore, participants with lifestyle factors known to affect vitamin D homeostasis were also excluded. We selected 23 target SNPs in five genes that encode key proteins of vitamin D metabolism (NADSYN1, GC, CYP24A1, CYP2R1, VDR). RESULTS: Variants in 2 genetic polymorphisms; rs2853564 (VDR) and rs11023374 (CYP2R1) showed a significant association with participants' BMI. These associations survived further adjustment for total-, free-, or bioactive-25(OH) vitamin D levels, although the variance explained by these 2 SNPS in BMI heterogeneity was only 3.2%. CONCLUSION: Our results show two novel examples of the relationship between genetics of vitamin D and BMI, highlighting the potential role of vitamin D hormone in the physiology of obesity

    Electro-anatomical mapping of the left atrium before and after cryothermal balloon isolation of the pulmonary veins

    Get PDF
    Introduction: The 28 mm cryoballoon catheter is a device used for pulmonary vein isolation (PVI). The aim of this study was to evaluate the extent of the ablation in the antral regions of the left atrium. Methods and Results: Eighteen patients with drug refractory, symptomatic, paroxysmal AF were enrolled. A 3D electroanatomic reconstruction of the left atrium was made before and after successful PVI with the 28 mm cryoballoon. Markers were placed at the ostium. Sixteen patients were mapped. Fourteen patients had 4 veins each, and 2 patients had a common ostium of the left sided veins. All separate ostia were isolated in the antral region. The two common ostia showed ostial isolation. There was a significant difference in vein size between the common (29 and 31 mm) and the separate ostia (19∈±∈4 mm) (p∈<∈0.01). The performance of an additional segmental ablation if balloon PVI did not eliminate all electrical activity, did not influence the extent of the ablation. The earliest left atrial activation during sinus rhythm was located in the superior septal region before ablation in all patients. After ablation, two patients showed a substantial downward shift towards the middle and inferior septal region respectively (NS). Four patients demonstrated a slight downward shift of the first activation. Conclusions: In cryoballoon PVI, the majority of the veins undergo antral isolation. Veins with a diameter larger than the balloon, are isolated ostially. In individual cases, the left atrial activation sequence appears to be altered after ablation

    Visualization of elusive structures using intracardiac echocardiography: Insights from electrophysiology

    Get PDF
    Electrophysiological mapping and ablation techniques are increasingly used to diagnose and treat many types of supraventricular and ventricular tachycardias. These procedures require an intimate knowledge of intracardiac anatomy and their use has led to a renewed interest in visualization of specific structures. This has required collaborative efforts from imaging as well as electrophysiology experts. Classical imaging techniques may be unable to visualize structures involved in arrhythmia mechanisms and therapy. Novel methods, such as intracardiac echocardiography and three-dimensional echocardiography, have been refined and these technological improvements have opened new perspectives for more effective and accurate imaging during electrophysiology procedures. Concurrently, visualization of these structures noticeably improved our ability to identify intracardiac structures. The aim of this review is to provide electrophysiologists with an overview of recent insights into the structure of the heart obtained with intracardiac echocardiography and to indicate to the echo-specialist which structures are potentially important for the electrophysiologist

    Minimally interrupted novel oral anticoagulant versus uninterrupted vitamin K antagonist during atrial fibrillation ablation

    Get PDF
    The safety and efficacy of a minimally interrupted novel oral anticoagulant (NOAC) strategy at the time of atrial fibrillation (AF) ablation is uncertain. The purpose of this study was to compare rates of bleeding and thromboembolic events between minimally interrupted NOAC and uninterrupted vitamin K antagonist (VKA) in patients undergoing AF ablation.This was a retrospective single-center cohort study of consecutive patients who underwent AF catheter ablation between January 2013 and April 2017. Endpoints included major bleeding, clinically relevant non-major bleeding and systemic thromboembolic event from the time of ablation through 30 days. Bleeding events were defined by the Bleeding Academic Research Consortium (BARC) and International Society on Thrombosis and Haemostasis (ISTH).A total of 637 patients were included in the analysis, 520 patients used uninterrupted VKA and 117 patients minimally interrupted NOAC (dabigatran: n = 68; apixaban: n = 30; rivaroxaban, n = 14; edoxaban, n = 5). The rate of clinically relevant non-major bleeding was lower in the NOAC group in comparison to the VKA group (BARC type 2: 2.6% versus 8.3%, P = 0.03; ISTH: 0% versus 3.8%, P = 0.03). Rates of major bleeding were similar between groups (BARC type 3 to 5: 3.4% versus 4.2%, P = NS; ISTH: 6.0% versus 8.7%, P = NS; for NOAC and VKA groups, respectively). Rates of systemic embolism were 0% with minimally interrupted NOAC, and 0.6% with uninterrupted VKA (P = NS).In patients undergoing AF ablation, anticoagulation with minimally interrupted NOAC was associated with fewer clinically relevant non-major bleeding events in comparison with uninterrupted VKA without compromising thromboembolic safety

    Pocket hematoma after pacemaker or defibrillator surgery:Direct oral anticoagulants versus vitamin K antagonists

    Get PDF
    BACKGROUND: Direct oral anticoagulants (DOACs) are the preferred choice of oral anticoagulation in patients with atrial fibrillation (AF). Randomized trials have demonstrated the efficacy and safety of DOAC in patients undergoing a cardiac implantable electronic device procedure (CIED); however, there is limited real-world data. OBJECTIVE: To evaluate the outcome of patients undergoing an elective CIED procedure in a tertiary referral center with an interrupted DOAC or continued vitamin K antagonist (VKA) regimen. METHODS: This was a retrospective single-center study of consecutive patients with AF undergoing an elective CIED procedure between January 2016 and June 2019. The primary endpoint was a clinically significant pocket hematoma < 30 days after surgery. The secondary endpoint was any systemic thromboembolic complication < 30 days after surgery. RESULTS: Of a total of 1,033 elective CIED procedures, 283 procedures were performed in patients with AF using oral anticoagulation. One-third of the procedures were performed under DOAC (N = 81, 29%) and the remainder under VKA (N = 202, 71%). The DOAC group was younger, had less chronic renal disease, more paroxysmal AF and a lower HAS-BLED score. The VKA group more often underwent a generator change only in comparison to the DOAC group. Clinically significant pocket hematoma occurred in 5 patients (2.5%) in the VKA group and did not occur in the DOAC group (P = 0.33). There were no thromboembolic events reported. CONCLUSION: In patients with AF undergoing an elective CIED procedure, the risk of a pocket hematoma and a systemic thromboembolic event is comparably low when using either continued VKA or interrupted DOAC

    Intracardiac echocardiography to guide transseptal catheterization for radiofrequency catheter ablation of left-sided accessory pathways: two case reports

    Get PDF
    Intracardiac echocardiography (ICE) is a useful tool for guiding transseptal puncture during electrophysiological mapping and ablation procedures. Left-sided accessory pathways (LSAP) can be ablated by using two different modalities: retrograde approach through the aortic valve and transseptal approach with puncture of the fossa ovalis. We shall report two cases of LSAP where transcatheter radiofrequency ablation (TCRFA) was firstly attempted via transaortic approach with ineffective results. Subsequently, a transseptal approach under ICE guidance has been performed. During atrial septal puncture ICE was able to locate the needle tip position precisely and provided a clear visualization of the "tenting effect" on the fossa ovalis. ICE allowed a better mapping of the mitral ring and a more effective catheter ablation manipulation and tip contact which resulted in a persistent and complete ablation of the accessory pathway with a shorter time of fluoroscopic exposure. ICE-guided transseptal approach might be a promising modality for TCRFA of LSAP

    Evaluating Real-World Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology Final 2-Year Outcome Data of the EWOLUTION Trial Focusing on History of Stroke and Hemorrhage

    Get PDF
    BACKGROUND: Left atrial appendage occlusion with WATCHMAN has emerged as viable alternative to vitamin K antagonists in randomized controlled trials. Evaluating real-life clinical outcomes in atrial fibrillation patients receiving the WATCHMAN left atrial appendage closure technology was designed to collect prospective multicenter outcomes of thromboembolic events, bleeding, and mortality for patients implanted with a WATCHMAN in routine daily practice. METHODS: One thousand twenty patients with a WATCHMAN implant procedure were prospectively followed in 47 centers. Left atrial appendage occlusion indication was based on the European Society of Cardiology guidelines. Follow-up and imaging were performed per local practice up to a median follow-up of 2 years. RESULTS: Included population was old (age 73.4±8.9 years), at high risk for stroke (311 prior ischemic stroke/transient ischemic attack and 153 prior hemorrhagic stroke) and bleeding (318 prior major bleeding), with CHA2 DS2 -VASc score ≥5 in 49%, hypertension, abnormal renal/liver function, stroke, bleeding history or predisposition, Labile international normalized ratio, elderly, drugs/alcohol concomitantly ≥3 in 40% and oral anticoagulation contraindication in 72%. During follow-up, 161 patients (16.4%) died, 22 strokes were observed (1.3/100 patient-years, 83% reduction versus historic data), and 47 major nonprocedural bleeding events (2.7/100 patient-years, 46% reduction versus historic data). Stroke and bleeding rates were consistently lower than historic data in those with prior ischemic (−76% and −41%) or hemorrhagic (−81% and 67%) stroke and prior bleeding (−85% and −30%). Lowest bleeding rates were seen in patients with early discontinuation of dual antiplatelet therapy. Patients with early discontinuation of antithrombotic therapy showed lower bleeding rates, while they were highest for those with prior bleeding. Device thrombus was observed in 34 patients (4.1%) and was not correlated to drug regimen during follow-up (P=0.28). CONCLUSIONS: During the complete 2-year follow-up of Evaluating RealLife Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology, patients with a WATCHMAN left atrial appendage occlusion device had consistently low rates of stroke and nonprocedural bleeding, although most were contraindicated to oral anticoagulation and used only single antiplatelet therapy or nothing
    corecore