34 research outputs found

    A new device to seal large coronary aneurysms: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Coronary artery aneurysm is an uncommon disease. It is defined as a coronary artery dilatation, exceeding the diameter of the normal adjacent segment or the diameter of the patient's largest coronary vessel by 1.5 to 2 times. Coronary artery aneurysms are typically diagnosed by coronary angiography. The prognosis of coronary artery aneurysm is not well known and the management is challenging.</p> <p>Case presentation</p> <p>A 68-year-old Italian-Caucasian man presented to our hospital with angina. Coronary angiography revealed a large coronary aneurysm of the right coronary artery, which was successfully treated by the percutaneous implantation of an MGuard™stent.</p> <p>Conclusion</p> <p>This case report provides evidence that coronary artery aneurysms, even if very large, can be safely treated by MGuard™stent implantation. We strongly emphasize the high flexibility and good deliverability of this device, which leads to the complete exclusion of the aneurysm mediated by the process of endothelization of its thin mesh sleeves.</p

    Prevalence and morphology of coronary artery ectasia with dual-source CT coronary angiography

    Full text link
    To assess the prevalence and morphological characteristics of coronary artery ectasia (CAE) with CT coronary angiography (CTCA) in comparison to conventional catheterangiography (CCA). Dual-source CTCA examinations from 677 consecutive patients (223 women; median age 57 years) were retrospectively evaluated by two blinded observers for the presence of CAE defined as a diameter enlargement >/=1.5 times the diameter of adjacent normal coronary segments. Vessel diameters and contrast attenuation within and proximal to ectatic segments were measured. CCA was used to compare measurements obtained from CTCA with the coronary flow velocity by using the thrombolysis in myocardial infarction (TIMI) frame count. CTCA identified CAE in 20 of 677 (3%) patients. CCA was performed in ten of these patients. CAE diameter measurements with CTCA (10.0 +/- 5.4 mm) correlated significantly (r = 0.92, p < 0.001) with the CCA measurements (8.8 +/- 4.9 mm), but had higher diameters (levels of agreement: -1.0 to 3.4 mm). Contrast attenuation was significantly lower in the ectatic (343 +/- 63 HU) than in the proximal (394 +/- 60 HU) segments (p < 0.01). The attenuation difference significantly correlated with the CAE ratio (r = 0.67, p < 0.01) and the TIMI frame count (r = 0.58, p < 0.05). The prevalence of CAE in a population examined by CTCA is around 3%. Contrast attenuation measurements with CTCA correlate well with the flow alterations assessed with CCA
    corecore