619 research outputs found

    Disordered, strongly scattering porous materials as miniature multipass gas cells

    Full text link
    Spectroscopic gas sensing is both a commercial success and a rapidly advancing scientific field. Throughout the years, massive efforts have been directed towards improving detection limits by achieving long interaction pathlengths. Prominent examples include the use of conventional multipass gas cells, sophisticated high-finesse cavities, gas-filled holey fibers, integrating spheres, and diffusive reflectors. Despite this rich flora of approaches, there is a continuous struggle to reduce size, gas volume, cost and alignment complexity. Here, we show that extreme light scattering in porous materials can be used to realise miniature gas cells. Near-infrared transmission through a 7 mm zirconia (ZrO2) sample with a 49% porosity and subwavelength pore structure (on the order of 100 nm) gives rise to an effective gas interaction pathlength above 5 meters, an enhancement corresponding to 750 passes through a conventional multipass cell. This essentially different approach to pathlength enhancement opens a new route to compact, alignment-free and low-cost optical sensor systems

    System for integrated interstitial photodynamic therapy and dosimetric monitoring

    Get PDF
    Photodynamic therapy for the treatment of cancer relies on the presence of light, sensitizer and oxygen. By monitoring these three parameters during the treatment a better understanding and treatment control could possibly be achieved. Here we present data from in vivo treatments of solid skin tumors using an instrument for interstitial photodynamic therapy with integrated dosimetric monitoring. By using intra-tumoral ALA-administration and interstitial light delivery solid tumors are targeted. The same fibers are used for measuring the fluence rate at the treatment wavelength, the sensitizer fluorescence and the local blood oxygen saturation during the treatment. The data presented is based on 10 treatments in 8 patients with thick basal cell carcinomas. The fluence rate measurements at 635 nm indicate a major treatment induced absorption increase, leading to a limited light penetration at the treatment wavelength. This leads to a far from optimal treatment since the absorption increase prevents peripheral tumor regions from being fully treated. An interactive treatment has been implemented assisting the physician in delivering the correct light dose. The absorption increase can be compensated for by either prolonging the treatment time or increasing the output power of each individual treatment fiber. The other parameters of importance, i.e. the sensitizer fluorescence at 705 nm and the local blood oxygen saturation, are monitored in order to get an estimate of the amount of photobleaching and oxygen consumption. Based on the oxygen saturation signal, a fractionized irradiation can be introduced in order to allow for a re-oxygenation of the tissu

    Laser-induced fluorescence studies of the biodistribution of carotenoporphyrins in mice.

    Get PDF
    The biodistribution of two recently developed tumour markers, trimethylated (CP(Me)3) and trimethoxylated (CP(OMe)3) carotenoporphyrin, was investigated by means of laser-induced fluorescence (LIF) after i.v. injection into 38 tumour-bearing (MS-2 fibrosarcoma) female Balb/c mice. At 3, 24, 48 or 96 h after administration, the carotenoporphyrin fluorescence was measured in tumoral and peritumoral tissue, as well as in the abdominal, thoracic and cranial cavities. The fluorescence was induced by a nitrogen laser-pumped dye laser, emitting light at 425 nm, and analysed by a polychromator equipped with an image-intensified CCD camera. The fluorescence was evaluated at 490, 655 and 720 nm: the second and third wavelengths represent the carotenoporphyrin (CP)-related peaks, whereas the first one is close to the peak of the tissue autofluorescence. The tumour and the liver were the two tissue types showing the strongest carotenoporphyrin-related fluorescence, whereas the cerebral cortex and muscle consistently exhibited weak substance-related fluorescence. In most tissue types, the fluorescence intensities decreased over time. A few exceptions were observed, notably the liver, in which the intensity remained remarkably constant over the time period investigated

    High-contrast Doppler-free transmission spectroscopy

    Get PDF
    By applying Doppler-free saturated absorption spectroscopy in the regime of high integrated sample absorption, high-contrast Doppler-free laser transmission signals can be obtained as demonstrated in experiments on the sodium D lines. Natural linewidth background-free signals are observed

    Laser-induced fluorescence in malignant and normal tissue in mice injected with two different carotenoporphyrins.

    Get PDF
    Laser-induced fluorescence (LIF) was used to characterise the localisation of an intravenously administered trimethylated carotenoporphyrin [CP(Me)3] and a trimethoxylated carotenoporphyrin [CP(OMe)3] in an intramuscularly transplanted malignant tumour (MS-2 fibrosarcoma) and healthy muscle in female Balb/c mice, 3, 24, 48 and 96 h post injection. The fluorescence was induced with a dye laser pumped by a nitrogen laser, emitting light at 425 nm. The fluorescence spectra were recorded in the region 455-760 nm using a polychromator equipped with an image-intensified CCD camera. The tumour/peritumoral muscle ratio was about 5:1 for CP(Me)3 and about 6:1 for CP(OMe)3 in terms of the background-free fluorescence intensity, which peaked at about 655 nm. By including the endogenous tissue fluorescence, the contrast was further enhanced by a factor of approximately 2

    Time-resolved x-ray spectroscopy of optical-field-ionized plasmas

    Get PDF
    The time-dependent soft X-ray emission of helium and nitrogen plasmas generated by optical-field ionization is reported. The experiments were carried out by focusing pulses of the high-power Ti:sapphire laser of the Lund Institute of Technology (lambda = 796 nm, pulse duration 150 fs, pulse energy 150 mJ) to a 50-mu m diameter spot close to a nozzle, using He and N-2 as target gases. The emission on He+, N4+, and N3+ resonance lines was recorded by means of a flat-field grating spectrometer coupled to an X-ray streak camera. A pronounced difference in the temporal shape of the emission of the Lyman-alpha line of hydrogen-like helium and of the 2p-3d resonance lines of lithium-like and beryllium-like nitrogen was observed. The helium line exhibited an initial spike followed by a slow revival of the emission, whereas the nitrogen lines showed a slow decay after a fast initial rise. These observations are explained with the help of simulations

    High-order Harmonic-generation In Rare-gases With An Intense Short-pulse Laser

    Get PDF
    We present experimental studies of high-order harmonic generation in the rare gases performed with a short-pulse titanium sapphire laser operating at 794 nm in the 10(14)-10(15) W/cm2 range. The harmonic yields generated in neon and in argon are studied for all orders as a function of the laser intensity. They vary first rather steeply, in the cutoff region, then much more slowly in the plateau region, and, finally, they saturate when the medium gets ionized. The dependence of the high-order harmonic cutoff with the laser intensity in neon and argon is found to be lower than that predicted in single-atom theories. We observe high-order harmonics in argon and xenon (up to the 65th and 45th, respectively) at 10(15) W/cm2, which we attribute to harmonic generation from ions. We also show how the harmonic and fundamental spectra get blueshifted when the medium becomes ionized

    Laser spectroscopy using beam-overlap modulation

    Get PDF
    A new Doppler-free laser spectroscopy method is demonstrated that employs modulation of the position of a laser beam rather than the commonly used intensity or polarization modulation. The technique is applicable in saturated absorption as well as fluorescence measurements, as is illustrated in experiments on sodium and iodine lines. A particular feature of the method is that Doppler- and background-free fluorescence spectra can be recorded without using intermodulation techniques
    • …
    corecore