12 research outputs found

    Does Experimental Anterior Knee Pain Alter Effects of Running on Femoral Articular Cartilage Thickness and Volume? A Pilot Study

    Get PDF
    Anterior knee pain is a common problem for runners that often alters running biomechanics. It is unclear how/if changes in running biomechanics due to anterior knee pain affect knee articular cartilage health. PURPOSE: To determine if experimental anterior knee pain during running acutely alters deformation in femoral articular cartilage due to running. METHODS: 10 runners completed three sessions that each in- volved a 60-min treadmill run: a control, sham, and pain session. Experimental anterior knee pain was in- duced during the pain session via a continuous infusion of hypertonic saline into the infrapatellar fat pad. The sham and control sessions involved a continuous infusion of physiological saline and no infusion, re- spectively. Before and after running, magnetic resonance imaging was used to quantify femoral articular cartilage thickness and volume. A repeated measures ANOVA was used to evaluate effects of running with experimental anterior knee pain on perceived knee pain and femoral articular cartilage deformation (α = 0.05). RESULTS: Perceived anterior knee pain was significantly greater during the pain session relative to the control and sham sessions (p p = 0.05), and more due to the pain session run (-57.7 ± 157.4 mm3) than the control session run (p = 0.09). No significant effects of session were observed for medial or lateral thickness or lateral volume. CONCLUSION: Articular cartilage response to running (medial femoral volume) was different for the pain and sham sessions relative to the control session. The physiological and hypertonic saline infusions appeared to alter medial knee articular cartilage response to running. These changes might be due to altered biomechanics due to the infusions. Additional research is needed to clarify the cause of the altered response to running

    Validation of the Apple Watch for Estimating Moderate-to-Vigorous Physical Activity and Activity Energy Expenditure in School-Aged Children.

    Get PDF
    The Apple Watch is one of the most popular wearable devices designed to monitor physical activity (PA). However, it is currently unknown whether the Apple Watch accurately estimates children's free-living PA. Therefore, this study assessed the concurrent validity of the Apple Watch 3 in estimating moderate-to-vigorous physical activity (MVPA) time and active energy expenditure (AEE) for school-aged children under a simulated and a free-living condition. Twenty elementary school students (Girls: 45%, age: 9.7 ± 2.0 years) wore an Apple Watch 3 device on their wrist and performed prescribed free-living activities in a lab setting. A subgroup of participants (N = 5) wore the Apple Watch for seven consecutive days in order to assess the validity in free-living condition. The K5 indirect calorimetry (K5) and GT3X+ were used as the criterion measure under simulated free-living and free-living conditions, respectively. Mean absolute percent errors (MAPE) and Bland-Altman (BA) plots were conducted to assess the validity of the Apple Watch 3 compared to those from the criterion measures. Equivalence testing determined the statistical equivalence between the Apple Watch and K5 for MVPA time and AEE. The Apple Watch provided comparable estimates for MVPA time (mean bias: 0.3 min, p = 0.91, MAPE: 1%) and for AEE (mean bias: 3.8 kcal min, p = 0.75, MAPE: 4%) during the simulated free-living condition. The BA plots indicated no systematic bias for the agreement in MVPA and AEE estimates between the K5 and Apple Watch 3. However, the Apple Watch had a relatively large variability in estimating AEE in children. The Apple Watch was statistically equivalent to the K5 within ±17.7% and ±20.8% for MVPA time and AEE estimates, respectively. Our findings suggest that the Apple Watch 3 has the potential to be used as a PA assessment tool to estimate MVPA in school-aged children

    The Validity of MotionSense HRV in Estimating Sedentary Behavior and Physical Activity under Free-Living and Simulated Activity Settings.

    Get PDF
    MotionSense HRV is a wrist-worn accelerometery-based sensor that is paired with a smartphone and is thus capable of measuring the intensity, duration, and frequency of physical activity (PA). However, little information is available on the validity of the MotionSense HRV. Therefore, the purpose of this study was to assess the concurrent validity of the MotionSense HRV in estimating sedentary behavior (SED) and PA. A total of 20 healthy adults (age: 32.5 ± 15.1 years) wore the MotionSense HRV and ActiGraph GT9X accelerometer (GT9X) on their non-dominant wrist for seven consecutive days during free-living conditions. Raw acceleration data from the devices were summarized into average time (min/day) spent in SED and moderate-to-vigorous PA (MVPA). Additionally, using the Cosemed K5 indirect calorimetry system (K5) as a criterion measure, the validity of the MotionSense HRV was examined in simulated free-living conditions. Pearson correlations, mean absolute percent errors (MAPE), Bland-Altman (BA) plots, and equivalence tests were used to examine the validity of the MotionSense HRV against criterion measures. The correlations between the MotionSense HRV and GT9X were high and the MAPE were low for both the SED (r = 0.99, MAPE = 2.4%) and MVPA (r = 0.97, MAPE = 9.1%) estimates under free-living conditions. BA plots illustrated that there was no systematic bias between the MotionSense HRV and criterion measures. The estimates of SED and MVPA from the MotionSense HRV were significantly equivalent to those from the GT9X; the equivalence zones were set at 16.5% for SED and 29% for MVPA. The estimates of SED and PA from the MotionSense HRV were less comparable when compared with those from the K5. The MotionSense HRV yielded comparable estimates for SED and PA when compared with the GT9X accelerometer under free-living conditions. We confirmed the promising application of the MotionSense HRV for monitoring PA patterns for practical and research purposes

    Inter-Device Agreement between Fitbit Flex 1 and 2 for Assessing Sedentary Behavior and Physical Activity

    No full text
    This study examined the inter-model agreement between the Fitbit Flex (FF) and FF2 in estimating sedentary behavior (SED) and physical activity (PA) during a free-living condition. 33 healthy adults wore the FF and FF2 on non-dominant wrist for 14 consecutive days. After excluding sleep and non-wear time, data from the FF and FF2 was converted to the time spent (min/day) in SED and PA using a proprietary algorithm. Pearson’s correlation was used to evaluate the association between the estimates from FF and FF2. Mean absolute percent errors (MAPE) were used to examine differences and measurement agreement in SED and PA estimates between FF and FF2. Bland-Altman (BA) plots were used to examine systematic bias between two devices. Equivalence testing was conducted to examine the equivalence between the FF and FF2. The FF2 had strong correlations with the FF in estimating SED and PA times. Compared to the FF, the FF2 yielded similar SED and PA estimates along with relatively low measurement discords and did not have significant systematic biases for SED and Moderate-to-vigorous PA estimates. Our findings suggest that researchers may choose FF2 as a measurement of SED and PA when FF is not available in the market during the longitudinal PA research

    The Validity of MotionSense HRV in Estimating Sedentary Behavior and Physical Activity under Free-Living and Simulated Activity Settings

    No full text
    MotionSense HRV is a wrist-worn accelerometery-based sensor that is paired with a smartphone and is thus capable of measuring the intensity, duration, and frequency of physical activity (PA). However, little information is available on the validity of the MotionSense HRV. Therefore, the purpose of this study was to assess the concurrent validity of the MotionSense HRV in estimating sedentary behavior (SED) and PA. A total of 20 healthy adults (age: 32.5 ± 15.1 years) wore the MotionSense HRV and ActiGraph GT9X accelerometer (GT9X) on their non-dominant wrist for seven consecutive days during free-living conditions. Raw acceleration data from the devices were summarized into average time (min/day) spent in SED and moderate-to-vigorous PA (MVPA). Additionally, using the Cosemed K5 indirect calorimetry system (K5) as a criterion measure, the validity of the MotionSense HRV was examined in simulated free-living conditions. Pearson correlations, mean absolute percent errors (MAPE), Bland–Altman (BA) plots, and equivalence tests were used to examine the validity of the MotionSense HRV against criterion measures. The correlations between the MotionSense HRV and GT9X were high and the MAPE were low for both the SED (r = 0.99, MAPE = 2.4%) and MVPA (r = 0.97, MAPE = 9.1%) estimates under free-living conditions. BA plots illustrated that there was no systematic bias between the MotionSense HRV and criterion measures. The estimates of SED and MVPA from the MotionSense HRV were significantly equivalent to those from the GT9X; the equivalence zones were set at 16.5% for SED and 29% for MVPA. The estimates of SED and PA from the MotionSense HRV were less comparable when compared with those from the K5. The MotionSense HRV yielded comparable estimates for SED and PA when compared with the GT9X accelerometer under free-living conditions. We confirmed the promising application of the MotionSense HRV for monitoring PA patterns for practical and research purposes

    Fault-Tolerant Operation under Single-Phase Open in Mono Inverter Dual Parallel SMPMSM with Single Shaft

    No full text
    This paper presents a fault-tolerant operation for dual three-phase surface-mounted permanent magnet machines (SPMSMs) that were both electrically connected on three winding phases and mechanically connected on one shaft. The open-phase fault-tolerant operation is considered in dual three-phase SPMSMs drive thus combining motor drive of three-phase and single-phase. The proposed method controls the torque of each motor with different phases using a single inverter. In order to control these motors, the torque and current are distributed between the motors with the specific ratio. Methods for minimizing torque ripple and copper losses and maximizing the output torque of the three-phase motor are stated in this paper. Accordingly, a system with cost-effective and enhanced reliability is proposed without any configuration adjustment or auxiliary switching devices. The mathematical analysis and experiments are presented to verify the feasibility of the proposed method. After the fault, the resulting system is able to provide up to 75% of the rated torque, and up to 50% of the torque can be utilized without any torque ripple.N

    Fault-Tolerant Operation Under Single-Phase Open in Mono Inverter Dual Parallel SMPMSM With Single Shaft

    No full text

    Influence of Tennis Racquet Kinematics on Ball Topspin Angular Velocity and Accuracy during the Forehand Groundstroke

    No full text
    Forehand groundstroke effectiveness is important for tennis success. Ball topspin angular velocity (TAV) and accuracy are important for forehand groundstroke effectiveness, and have been extensively studied, previously; despite previous, quality studies, it was unclear whether certain racquet kinematics relate to ball TAV and shot accuracy during the forehand groundstroke. This study evaluated potential relationships between (1) ball TAV and (2) forehand accuracy, and five measures of racquet kinematics: racquet head impact angle (i.e., closed or open face), horizontal and vertical racquet head velocity before impact, racquet head trajectory (resultant velocity direction, relative to horizontal) before impact, and hitting zone length (quasi-linear displacement, immediately before and after impact). Thirteen collegiate-level tennis players hit forehand groundstrokes in a biomechanics laboratory, where racquet kinematics and ball TAV were measured, and on a tennis court, to assess accuracy. Correlational statistics were used to evaluate potential relationships between racquet kinematics, and ball TAV (mixed model) and forehand accuracy (between-subjects model; α = 0.05). We observed an average (1) racquet head impact angle, (2) racquet head trajectory before impact, relative to horizontal, (3) racquet head horizontal velocity before impact, (4) racquet head vertical velocity before impact, and (5) hitting zone length of 80.4 ± 3.6˚, 18.6 ± 4.3˚, 15.4 ± 1.4 m·s-1, 6.6 ± 2.2 m·s-1, and 79.8 ± 8.6 mm, respectively; and an average ball TAV of 969 ± 375 revolutions per minute. Only racquet head impact angle and racquet head vertical velocity, before impact, significantly correlated with ball TAV (p < 0.01). None of the observed racquet kinematics significantly correlated to the measures of forehand accuracy. These results confirmed mechanical logic and indicate that increased ball TAV is associated with a more closed racquet head impact angle (ranging from 70 to 85˚, relative to the ground) and increased racquet head vertical velocity before impact

    The Effects of Playground Interventions on Accelerometer-Assessed Physical Activity in Pediatric Populations: A Meta-Analysis

    No full text
    Playgrounds are designed to be a safe, enjoyable, and effective means to promote physical activity in children and adolescents. The purpose of this study was to conduct a meta-analysis to determine the effectiveness of playground interventions for improving accelerometer-assessed ambulatory moderate-to-vigorous physical activity (MVPA) and to identify common aspects of playground interventions that may be beneficial to promote behavior change. An internet database search was performed. The final analyzed sample of studies was obtained from several criteria, including being a playground-based intervention targeting children or adolescents, having a control or comparison group, having an accelerometer-assessed MVPA outcome target variable, and reporting of the mean difference scores&rsquo; variability. A random-effects model meta-analysis was employed to obtain pooled effect sizes. Ten studies (n = 10) were analyzed from the internet search. The weighted pooled effect (Hedges&rsquo; g) across all studies was Hedges&rsquo; g = 0.13, 95% CI: 0.02&ndash;0.24, p = 0.023. There was moderate study heterogeneity (I2 = 55.3%) but no evidence for publication bias (p = 0.230). These results suggest that school-based playground interventions have a small effect on increasing accelerometer-assessed MVPA within the pediatric population. The playground should still be an environmental target during school or community-based interventions aimed at providing opportunities to promote MVPA
    corecore