27 research outputs found
Association of CNVs with methylation variation.
Germline copy number variants (CNVs) and single-nucleotide polymorphisms (SNPs) form the basis of inter-individual genetic variation. Although the phenotypic effects of SNPs have been extensively investigated, the effects of CNVs is relatively less understood. To better characterize mechanisms by which CNVs affect cellular phenotype, we tested their association with variable CpG methylation in a genome-wide manner. Using paired CNV and methylation data from the 1000 genomes and HapMap projects, we identified genome-wide associations by methylation quantitative trait locus (mQTL) analysis. We found individual CNVs being associated with methylation of multiple CpGs and vice versa. CNV-associated methylation changes were correlated with gene expression. CNV-mQTLs were enriched for regulatory regions, transcription factor-binding sites (TFBSs), and were involved in long-range physical interactions with associated CpGs. Some CNV-mQTLs were associated with methylation of imprinted genes. Several CNV-mQTLs and/or associated genes were among those previously reported by genome-wide association studies (GWASs). We demonstrate that germline CNVs in the genome are associated with CpG methylation. Our findings suggest that structural variation together with methylation may affect cellular phenotype
Laser Peripheral Iridotomy in Primary Angle Closure: A Report by the American Academy of Ophthalmology
To examine the efficacy and complications of laser peripheral iridotomy (LPI) in subjects with primary angle closure (PAC).Literature searches in the PubMed and Cochrane databases were last conducted in August 2017 and yielded 300 unique citations. Of these, 36 met the inclusion criteria and were rated according to the strength of evidence; 6 articles were rated level I, 11 articles were rated level II, and 19 articles were rated level III.Reported outcomes were change in angle width, effect on intraocular pressure (IOP) control, disease progression, and complications. Most of the studies (29/36, 81%) included only Asian subjects. Angle width (measured by gonioscopy, ultrasound biomicroscopy, and anterior segment OCT) increased after LPI in all stages of angle closure. Gonioscopically defined persistent angle closure after LPI was reported in 2% to 57% of eyes across the disease spectrum. Baseline factors associated with persistent angle closure included narrower angle and parameters representing nonpupillary block mechanisms of angle closure, such as a thick iris, an anteriorly positioned ciliary body, or a greater lens vault. After LPI, further treatment to control IOP was reported in 0%-8% of PAC suspect (PACS), 42% to 67% of PAC, 21% to 47% of acute PAC (APAC), and 83%-100% of PAC glaucoma (PACG) eyes. Progression to PACG ranged from 0% to 0.3% per year in PACS and 0% to 4% per year in PAC. Complications after LPI included IOP spike (8-17 mmHg increase from baseline in 6%-10%), dysphotopsia (2%-11%), anterior chamber bleeding (30%-41%), and cataract progression (23%-39%).Laser peripheral iridotomy increases angle width in all stages of primary angle closure and has a good safety profile. Most PACS eyes do not receive further intervention, whereas many PAC and APAC eyes, and most PACG eyes, receive further treatment. Progression to PACG is uncommon in PACS and PAC. There are limited data on the comparative efficacy of LPI versus other treatments for the various stages of angle closure; 1 randomized controlled trial each demonstrated superiority of cataract surgery over LPI in APAC and of clear lens extraction over LPI in PACG or PAC with IOP above 30 mmHg
Recommended from our members
Re: Radhakrishnan et al.: Ophthalmic Technology Assessment: Laser peripheral iridotomy in primary angle closure: a report by the American Academy of Ophthalmology (Ophthalmology. 2018;125:1110-1120) Reply
Recommended from our members
Swept-Source OCT for Evaluating the Lamina Cribrosa: A Report by the American Academy of Ophthalmology
To review the published literature on the use of swept-source (SS) OCT for evaluating the lamina cribrosa in glaucoma.A PubMed and Cochrane Library literature search initially conducted on March 3, 2017, and updated on June 26, 2018, yielded a total of 64 articles. Articles that were reviews or that were not published in English were excluded, and 29 were found to fit the inclusion criteria. The panel methodologist then assigned a level of evidence rating to each study. Fifteen studies were rated level III, 14 studies were rated level II, and no studies were rated level I.Different aspects of the lamina cribrosa were studied using SS-OCT, including the anterior lamina cribrosa curvature, anterior lamina cribrosa depth, anterior lamina cribrosa insertions, laminar thickness, focal lamina cribrosa defects (FLCDs), and lamina cribrosa microarchitecture. In general, imaging of the anterior lamina can be achieved reliably, although shadowing from blood vessels at the neuroretinal rim remains an issue. Imaging of the posterior lamina can be achieved with varying levels of success. In glaucoma, there is posterior migration of the anterior lamina cribrosa insertions as well as increased thinning and posterior curvature of the lamina cribrosa. Focal lamina cribrosa defects appear more commonly in glaucoma, and this may hint at the pathogenesis of axonal damage. In addition, there may be remodeling of the microarchitecture of the lamina, resulting in more variable laminar pores. There are limited studies comparing SS-OCT with spectral-domain (SD) OCT with regard to imaging of the lamina, but the difference in image quality between enhanced depth imaging (EDI) with SD-OCT and SS-OCT seems minimal.Imaging of the lamina cribrosa using SS-OCT has demonstrated that the lamina cribrosa is likely biomechanically active and that significant changes occur in glaucoma. The diagnostic utility of SS-OCT for lamina cribrosa imaging is promising, but standardized nomenclature, automated measurements, and longitudinal studies with larger and more diverse sample sizes are needed
The Effect of Phacoemulsification on Intraocular Pressure in Glaucoma Patients: A Report by the American Academy of Ophthalmology
To examine effects of phacoemulsification on longer-term intraocular pressure (IOP) in patients with medically treated primary open-angle glaucoma (POAG; including normal-tension glaucoma), pseudoexfoliation glaucoma (PXG), or primary angle-closure glaucoma (PACG), without prior or concurrent incisional glaucoma surgery.PubMed and Cochrane database searches, last conducted in December 2014, yielded 541 unique citations. Panel members reviewed titles and abstracts and selected 86 for further review. The panel reviewed these articles and identified 32 studies meeting the inclusion criteria, for which the panel methodologist assigned a level of evidence based on standardized grading adopted by the American Academy of Ophthalmology. One, 15, and 16 studies were rated as providing level I, II, and III evidence, respectively.All follow-up, IOP, and medication data listed are weighted means. In general, the studies reported on patients using few glaucoma medications (1.5-1.9 before surgery among the different diagnoses). For POAG, 9 studies (total, 461 patients; follow-up, 17 months) showed that phacoemulsification reduced IOP by 13% and glaucoma medications by 12%. For PXG, 5 studies (total, 132 patients; follow-up, 34 months) showed phacoemulsification reduced IOP by 20% and glaucoma medications by 35%. For chronic PACG, 12 studies (total, 495 patients; follow-up, 16 months) showed phacoemulsification reduced IOP by 30% and glaucoma medications by 58%. Patients with acute PACG (4 studies; total, 119 patients; follow-up, 24 months) had a 71% reduction from presenting IOP and rarely required long-term glaucoma medications when phacoemulsification was performed soon after medical reduction of IOP. Trabeculectomy after phacoemulsification was uncommon; the median rate reported within 6 to 24 months of follow-up in patients with controlled POAG, PXG, or PACG was 0% and was 7% in patients with uncontrolled chronic PACG.Phacoemulsification typically results in small, moderate, and marked reductions of IOP and medications for patients with POAG, PXG, and PACG, respectively, and using 1 to 2 medications before surgery. Trabeculectomy within 6 to 24 months after phacoemulsification is rare in such patients. However, reports on its effects in eyes with advanced disease or poor IOP control before surgery are few, particularly for POAG and PXG
Disinfection of Tonometers: A Report by the American Academy of Ophthalmology
To examine the efficacy of various disinfection methods for reusable tonometer prisms in eye care and to highlight how disinfectants can damage tonometer tips and cause subsequent patient harm.Literature searches were conducted last in October 2016 in the PubMed and the Cochrane Library databases for original research investigations. Reviews, non-English language articles, nonophthalmology articles, surveys, and case reports were excluded.The searches initially yielded 64 unique citations. After exclusion criteria were applied, 10 laboratory studies remained for this review. Nine of the 10 studies used tonometer prisms and 1 used steel discs. The infectious agents covered in this assessment include adenovirus 8 and 19, herpes simplex virus (HSV) 1 and 2, human immunodeficiency virus 1, hepatitis C virus, enterovirus 70, and variant Creutzfeldt-Jakob disease. All 4 studies of adenovirus 8 concluded that after sodium hypochlorite (dilute bleach) disinfection, the virus was undetectable, but only 2 of the 4 studies found that 70% isopropyl alcohol (e.g., alcohol wipes or soaks) eradicated all viable virus. All 3 HSV studies concluded that both sodium hypochlorite and 70% isopropyl alcohol eliminated HSV. Ethanol, 70% isopropyl alcohol, dilute bleach, and mechanical cleaning all lack the ability to remove cellular debris completely, which is necessary to prevent prion transmission. Therefore, single-use tonometer tips or disposable tonometer covers should be considered when treating patients with suspected prion disease. Damage to tonometer prisms can be caused by sodium hypochlorite, 70% isopropyl alcohol, 3% hydrogen peroxide, ethyl alcohol, water immersion, ultraviolet light, and heat exposure. Disinfectants can cause tonometer tips to swell and crack by dissolving the glue that holds the hollow tip together. The tonometer tip cracks can irritate the cornea, harbor microbes, or allow disinfectants to enter the interior of the tonometer tip.Sodium hypochlorite (dilute bleach) offers effective disinfection against adenovirus and HSV, the viruses commonly associated with nosocomial outbreaks in eye care. Tonometer prisms should be examined regularly for signs of damage
Recommended from our members
The Effect of Anti-Vascular Endothelial Growth Factor Agents on Intraocular Pressure and Glaucoma: A Report by the American Academy of Ophthalmology
To assess the effect of intravitreal injections of anti-vascular endothelial growth factor (VEGF) agents on immediate and long-term intraocular pressure (IOP) elevation and glaucoma.
Literature searches of the PubMed and Cochrane databases, last conducted in April 2018, yielded 253 unique citations. Of these, 41 met the inclusion criteria and were rated according to the strength of evidence. Two articles were rated level I, 17 were rated level II, and 15 were rated level III; an additional 7 were excluded because of poor study design and lack of relevance to the topic under evaluation.
The studies that reported on short-term IOP elevation (i.e., between 0 and 60 minutes) showed that an immediate increase in IOP is seen in all patients when measured between 0 and 30 minutes of intravitreal injection and that the IOP elevation decreases over time. The data on long-term IOP elevation were mixed; 7 studies reported that between 4% and 15% of patients developed sustained elevation of IOP at 9 to 24 months after injection, whereas 6 studies found no long-term change in IOP from 1 to 36 months after injection. Pretreatment with glaucoma medications, anterior chamber tap, vitreous reflux, longer intervals between injections, and longer axial lengths were associated with lower IOP elevations after injection. Data were mixed on the relationship between IOP increase and the type of intravitreal injection, number of intravitreal injections, preexisting glaucoma, and globe decompression before injection. There were no data on the onset or progression of glaucoma in the studies reviewed in this assessment.
Intravitreal injection of anti-VEGF agents results in an immediate and transient increase in IOP. A long-term increase in IOP also may be seen, and further studies are needed to determine at-risk populations. Although there is some suggestion in the literature, there is currently insufficient data to determine the impact of intravitreal anti-VEGF injections on glaucoma progression. Although pretreatment with glaucoma medications, performing anterior chamber paracentesis, or increasing the interval between injections may reduce the impact of transient IOP elevation, the clinical significance and associated risks of these interventions are unknown
Long-term effect of phacoemulsification on intraocular pressure using phakic fellow eye as control
To investigate the long-term effect of phacoemulsification on intraocular pressure (IOP) in patients with ocular hypertension and open-angle glaucoma.
Three multispecialty ophthalmology practices and one glaucoma specialty group.
Retrospective comparative case series.
Review of medical records of patients with open-angle glaucoma or ocular hypertension who had had unilateral phacoemulsification (without other prior or concurrent ophthalmic procedure) with the fellow eye remaining phakic at least 3 years postoperatively.
Preoperatively, the IOP in the surgical and fellow eyes in the 29 patients was 15.66 mm Hg ± 3.33 (SD) and 15.64 ± 4.23 mm Hg (P=.98), respectively. Postoperatively, it was 13.56 ± 2.04 mm Hg and 14.92 ± 2.85 mm Hg, respectively, at 4.5 months (P=.06); 14.88 ± 3.20 mm Hg and 15.27 ± 3.19 mm Hg, respectively, at 1 year (P=.67); 14.16 ± 2.61 mm Hg and 14.95 ± 2.79 mm Hg, respectively, at 2 years (P=.37); and 14.68 ± 3.44 mm Hg and 14.68 ± 2.68 mm Hg at 3 years (P=1.00), respectively. There was no significant difference in the mean number of IOP-lowering medications used in the surgical eyes (1.96 ± 1.40) and fellow eyes (2.08 ± 1.44) postoperatively (P=.77).
In a cohort of ocular hypertensive and glaucoma patients, uncomplicated phacoemulsification had no significant IOP-lowering effect compared with the phakic fellow eye for up to 3 years postoperatively. There was also no difference between the mean number of postoperative IOP-lowering medications used in the surgical and fellow eyes.
No author has a financial or proprietary interest in any material or method mentioned
Reproducibility of Scleral Spur Identification and Angle Measurements Using Fourier Domain Anterior Segment Optical Coherence Tomography
Purpose. To evaluate intraobserver and interobserver agreement in locating the scleral spur landmark (SSL) and anterior chamber angle measurements obtained using Fourier Domain Anterior Segment Optical Coherence Tomography (ASOCT) images. Methods. Two independent, masked observers (SR and AZC) identified SSLs on ASOCT images from 31 eyes with open and nonopen angles. A third independent reader, NPB, adjudicated SSL placement if identifications differed by more than 80 μm. Nine months later, SR reidentified SSLs. Intraobserver and interobserver agreement in SSL placement, trabecular-iris space area (TISA750), and angle opening distance (AOD750) were calculated. Results. In 84% of quadrants, SR’s SSL placements during 2 sessions were within 80 μm in both the X- and Y-axes, and in 77% of quadrants, SR and AZC were within 80 μm in both axes. In adjudicated images, 90% of all quadrants were within 80 μm, 88% in nonopen-angle eyes, and 92% in open-angle eyes. The intraobserver and interobserver correlation coefficients (with and without adjudication) were above 0.9 for TISA750 and AOD750 for all quadrants. Conclusions. Reproducible identification of the SSL from images obtained with FD-ASOCT is possible. The ability to identify the SSL allows reproducible measurement of the anterior chamber angle using TISA750 and AOD750