5,934 research outputs found

    Differential Pixel Value Coding for HEVC Lossless Compression

    Get PDF

    Line-based Intra Coding for High Quality Video Using H.264/AVC

    Get PDF

    Growth control of oxygen stoichiometry in homoepitaxial SrTiO3 films by pulsed laser epitaxy in high vacuum

    Get PDF
    In many transition metal oxides (TMOs), oxygen stoichiometry is one of the most critical parameters that plays a key role in determining the structural, physical, optical, and electrochemical properties of the material. However, controlling the growth to obtain high quality single crystal films having the right oxygen stoichiometry, especially in a high vacuum environment, has been viewed as a challenge. In this work, we show that through proper control of the plume kinetic energy, stoichiometric crystalline films can be synthesized without generating oxygen defects, even in high vacuum. We use a model homoepitaxial system of SrTiO3 (STO) thin films on single crystal STO substrates. Physical property measurements indicate that oxygen vacancy generation in high vacuum is strongly influenced by the energetics of the laser plume, and it can be controlled by proper laser beam delivery. Therefore, our finding not only provides essential insight into oxygen stoichiometry control in high vacuum for understanding the fundamental properties of STO-based thin films and heterostructures, but expands the utility of pulsed laser epitaxy of other materials as well

    Bone-added osteotome sinus floor elevation with simultaneous placement of non-submerged sand blasted with large grit and acid etched implants: a 5-year radiographic evaluation

    Get PDF
    PURPOSE: Implant survival rates using a bone-added osteotome sinus floor elevation (BAOSFE) procedure with simultaneous placement of a non-submerged sand blasted with large grit and acid etched (SLA) implant are well documented at sites where native bone height is less than 5 mm. This study evaluated the clinical results of non-submerged SLA Straumann implants placed at the time of the BAOSFE procedure at sites where native bone height was less than 4 mm. Changes in graft height after the BAOSFE procedure were also assessed using radiographs for 5 years after the implant procedure. METHODS: The BAOSFE procedure was performed on 4 patients with atrophic posterior maxillas with simultaneous placement of 7 non-submerged SLA implants. At least 7 standardized radiographs were obtained from each patient as follows: before surgery, immediately after implant placement, 6 months after surgery, every year for the next 3 years, and after more than 5 years had passed. Clinical and radiographic examinations were performed at every visit. Radiographic changes in graft height were calculated with respect to the implant's known length and the original sinus height. RESULTS: All implants were stable functionally, as well as clinically and radiographically, during the follow-up. Most of the radiographic reduction in the grafted bone height occurred in the first 2 years; reduction after 2 years was slight. CONCLUSIONS: The simultaneous placement of non-submerged SLA implants using the BAOSFE procedure is a feasible treatment option for patients with severe atrophic posterior maxillas. However, the grafted bone height is reduced during the healing period, and patients must be selected with care.ope

    A MODEL ON AN ENTRAINED BED-BUBBLING BED PROCESS FOR CO2 CAPTURE FROM FLUE GAS

    Get PDF
    A simplified model has been developed to investigate effects of important operating parameters on performance of an entrained-bed absorber and bubbling-bed regenerator system collecting CO2 from flue gas. The particle population balance was considered together with chemical reaction to determine the extent of conversion in both absorber and regenerator. Effects of several absorber parameters was tested in a laboratory scale process. The CO2 capture efficiency decreased as temperature or gas velocity increased. However, it increased with static bed height or moisture concentration. The CO2 capture efficiency was exponentially proportional to each parameter. Based on the absolute value of exponent of the parameter, the effect of gas velocity, static bed height, and moisture content was a half, one third, and one fourth as strong as that of temperature, respectively
    corecore