49 research outputs found

    Comparison of placental growth factor and fetal flow Doppler ultrasonography to identify fetal adverse outcomes in women with hypertensive disorders of pregnancy: an observational study.

    Get PDF
    BACKGROUND: Hypertensive disorders of pregnancy and intrauterine growth restriction (IUGR) are leading causes of maternal and perinatal morbidity and mortality. Failure to detect intrauterine growth restriction in women at high risk has been highlighted as a significant avoidable cause of serious fetal outcome. In this observational study we compare fetal flow using Doppler ultrasonography with a new test for placental growth factor (PlGF) to predict fetal adverse events. METHODS: Eighty-nine women with hypertensive disorders of pregnancy (24 with chronic hypertension, 17 with gestational hypertension, 12 with HELLP syndrome, 19 with preeclampsia and 17 with superimposed preeclampsia) were enrolled. A single maternal blood sample to measure free PlGF (Alere Triage) taken before 35 weeks of pregnancy was compared to the last Doppler ultrasound measurement of fetal flow before delivery. PlGF was classified as normal (PlGF>/=100 pg/ml), low (12<PlGF<100) or very low (PlGF</=12 pg/ml). A positive test for abnormal fetal flow was defined as either signs of centralisation of the fetal circulation or diastolic block or reverse flow in the umbilical artery or descending aorta; this was a criterion for delivery. Fetal outcomes were intrauterine growth restriction and birth before 37 weeks of pregnancy. RESULTS: In total 61/89 women had a preterm birth and 22 infants had IUGR. Of those who delivered preterm, 20/20 women with abnormal fetal flow and 36/41 (87.8%) women with normal fetal flow had low or very low PlGF. Of those infants with IUGR, 22/22 had low or very low maternal PlGF and 10/22 had abnormal fetal flow. CONCLUSIONS: PlGF may provide useful information before 35th gestational week to identify fetuses requiring urgent delivery, and those at risk of later adverse outcomes not identified by fetal flow Doppler ultrasonography

    Anticoagulation for non-valvular atrial aibrillation – towards a new beginning with ximelagatran

    Get PDF
    OBJECTIVES: Ximelagatran is a novel oral direct thrombin inhibitor. It has favorable pharmacodynamic properties, with a broad therapeutic range without the need for anticoagulation monitoring. We aimed to discover whether ximelagatran offers a genuine future replacement to warfarin for patients in persistent atrial fibrillation (AF). MATERIALS AND METHODS: We provide an evidence-based review of the relative merits and disadvantages of warfarin and aspirin. We subsequently present an overview of the evidence for the utility of ximelagatran in the treatment of AF. RESULTS: Adjusted dose warfarin is recommended over aspirin for patients in AF at high risk of future stroke. Some of this benefit is partially offset by the higher bleeding risks associated with warfarin therapy. The SPORTIF III and V studies have shown that ximelagatran is not inferior to warfarin in the prevention of all strokes in patients with AF (both persistent and paroxysmal). This benefit was partially offset by the finding of a significant elevation of liver transaminases (>3 × normal) in 6% of patients. CONCLUSIONS: Current data would suggest that ximelagatran might represent a future alternative to warfarin. The lack of need for anticoagulant monitoring has been partially offset by a need for regular monitoring of liver function. Further data from randomized clinical trials is clearly needed

    Discovery of Novel Hypermethylated Genes in Prostate Cancer Using Genomic CpG Island Microarrays

    Get PDF
    BACKGROUND: Promoter and 5' end methylation regulation of tumour suppressor genes is a common feature of many cancers. Such occurrences often lead to the silencing of these key genes and thus they may contribute to the development of cancer, including prostate cancer. METHODOLOGY/PRINCIPAL FINDINGS: In order to identify methylation changes in prostate cancer, we performed a genome-wide analysis of DNA methylation using Agilent human CpG island arrays. Using computational and gene-specific validation approaches we have identified a large number of potential epigenetic biomarkers of prostate cancer. Further validation of candidate genes on a separate cohort of low and high grade prostate cancers by quantitative MethyLight analysis has allowed us to confirm DNA hypermethylation of HOXD3 and BMP7, two genes that may play a role in the development of high grade tumours. We also show that promoter hypermethylation is responsible for downregulated expression of these genes in the DU-145 PCa cell line. CONCLUSIONS/SIGNIFICANCE: This study identifies novel epigenetic biomarkers of prostate cancer and prostate cancer progression, and provides a global assessment of DNA methylation in prostate cancer

    What are the basic self-monitoring components for cardiovascular risk management?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Self-monitoring is increasingly recommended as a method of managing cardiovascular disease. However, the design, implementation and reproducibility of the self-monitoring interventions appear to vary considerably. We examined the interventions included in systematic reviews of self-monitoring for four clinical problems that increase cardiovascular disease risk.</p> <p>Methods</p> <p>We searched Medline and Cochrane databases for systematic reviews of self-monitoring for: heart failure, oral anticoagulation therapy, hypertension and type 2 diabetes. We extracted data using a pre-specified template for the identifiable components of the interventions for each disease. Data was also extracted on the theoretical basis of the education provided, the rationale given for the self-monitoring regime adopted and the compliance with the self-monitoring regime by the patients.</p> <p>Results</p> <p>From 52 randomized controlled trials (10,388 patients) we identified four main components in self-monitoring interventions: education, self-measurement, adjustment/adherence and contact with health professionals. Considerable variation in these components occurred across trials and conditions, and often components were poorly described. Few trials gave evidence-based rationales for the components included and self-measurement regimes adopted.</p> <p>Conclusions</p> <p>The components of self-monitoring interventions are not well defined despite current guidelines for self-monitoring in cardiovascular disease management. Few trials gave evidence-based rationales for the components included and self-measurement regimes adopted. We propose a checklist of factors to be considered in the design of self-monitoring interventions which may aid in the provision of an evidence-based rationale for each component as well as increase the reproducibility of effective interventions for clinicians and researchers.</p

    A role for pharmacists in community-based post-discharge warfarin management: protocol for the 'the role of community pharmacy in post hospital management of patients initiated on warfarin' study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Shorter periods of hospitalisation and increasing warfarin use have placed stress on community-based healthcare services to care for patients taking warfarin after hospital discharge, a high-risk period for these patients. A previous randomised controlled trial demonstrated that a post-discharge service of 4 home visits and point-of-care (POC) International Normalised Ratio (INR) testing by a trained pharmacist improved patients' outcomes. The current study aims to modify this previously trialled service model to implement and then evaluate a sustainable program to enable the smooth transition of patients taking warfarin from the hospital to community setting.</p> <p>Methods/Design</p> <p>The service will be trialled in 8 sites across 3 Australian states using a prospective, controlled cohort study design. Patients discharged from hospital taking warfarin will receive 2 or 3 home visits by a trained 'home medicines review (HMR)-accredited' pharmacist in their 8 to 10 days after hospital discharge. Visits will involve a HMR, comprehensive warfarin education, and POC INR monitoring in collaboration with patients' general practitioners (GPs) and community pharmacists. Patient outcomes will be compared to those in a control, or 'usual care', group. The primary outcome measure will be the proportion of patients experiencing a major bleeding event in the 90 days after discharge. Secondary outcome measures will include combined major bleeding and thromboembolic events, death, cessation of warfarin therapy, INR control at 8 days post-discharge and unplanned hospital readmissions from any cause. Stakeholder satisfaction will be assessed using structured postal questionnaire mailed to patients, GPs, community pharmacists and accredited pharmacists at the completion of their study involvement.</p> <p>Discussion</p> <p>This study design incorporates several aspects of prior interventions that have been demonstrated to improve warfarin management, including POC INR testing, warfarin education and home visits by trained pharmacists. It faces several potential challenges, including the tight timeframe for patient follow-up in the post-discharge period. Its strengths lie in a strong multidisciplinary team and the utilisation of existing healthcare frameworks. It is hoped that this study will provide the evidence to support the national roll-out of the program as a new Australian professional community pharmacy service.</p> <p>Trial Registration</p> <p>Australian New Zealand Clinical Trials Registry Number <a href="http://www.anzctr.org.au/trial_view.aspx?ID=82959">12608000334303</a>.</p

    Track D Social Science, Human Rights and Political Science

    Full text link
    Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/138414/1/jia218442.pd

    Self-monitoring of oral anticoagulation: systematic review and meta-analysis of individual patient data

    Get PDF
    Background: Uptake of self-testing and self-management of oral anticoagulation has remained inconsistent, despite good evidence of their effectiveness. To clarify the value of self-monitoring of oral anticoagulation, we did a meta-analysis of individual patient data addressing several important gaps in the evidence, including an estimate of the effect on time to death, first major haemorrhage, and thromboembolism. / Methods: We searched Ovid versions of Embase (1980–2009) and Medline (1966–2009), limiting searches to randomised trials with a maximally sensitive strategy. We approached all authors of included trials and requested individual patient data: primary outcomes were time to death, first major haemorrhage, and first thromboembolic event. We did prespecified subgroup analyses according to age, type of control-group care (anticoagulation-clinic care vs primary care), self-testing alone versus self-management, and sex. We analysed patients with mechanical heart valves or atrial fibrillation separately. We used a random-effect model method to calculate pooled hazard ratios and did tests for interaction and heterogeneity, and calculated a time-specific number needed to treat. / Findings: Of 1357 abstracts, we included 11 trials with data for 6417 participants and 12 800 person-years of follow-up. We reported a significant reduction in thromboembolic events in the self-monitoring group (hazard ratio 0·51; 95% CI 0·31–0·85) but not for major haemorrhagic events (0·88, 0·74–1·06) or death (0·82, 0·62–1·09). Participants younger than 55 years showed a striking reduction in thrombotic events (hazard ratio 0·33, 95% CI 0·17–0·66), as did participants with mechanical heart valve (0·52, 0·35–0·77). Analysis of major outcomes in the very elderly (age ≥85 years, n=99) showed no significant adverse effects of the intervention for all outcomes. Interpretation: Our analysis showed that self-monitoring and self-management of oral anticoagulation is a safe option for suitable patients of all ages. Patients should also be offered the option to self-manage their disease with suitable health-care support as back-up. / Funding: UK National Institute for Health Research (NIHR) Technology Assessment Programme, UK NIHR National School for Primary Care Research
    corecore