58 research outputs found

    Direct and indirect methods for the quantification of leg volume: Comparison between water displacement volumetry, the disk model method and the frustum sign model method, using the correlation coefficient and the limits of agreement

    Get PDF
    Volume changes can be measured either directly by water-displacement volumetry or by various indirect methods in which calculation of the volume is based on circumference measurements. The aim of the present study was to determine the most appropriate indirect method for lower leg volume calculation using water displacement volumetry as a ‘golden standard’. For 20 male volunteers, age range: 20–35 years, the volume of both lower legs was determined directly by water-displacement volumetry, and indirectly by the frustum sign model method and the disc model method. Calculation of the correlation coefficient and the limits of agreement showed that water-displacement volumetry and the disc model method are interchangeable (r = + 0.99, mean ± 2s = − 45 ± 78 ml), whereas this does not hold for the frustum sign model (r = + 0.93, mean ± 2s = 521 ± 238 ml). In the clinical situation volume measurement can be valuable for monitoring of the severity of oedema or haematoma occurrence after surgery or severe trauma. This non-invasive diagnostic aid may be a valuable adjuvant means of diagnosis for several volume dependent disorders of the extremities

    Water displacement leg volumetry in clinical studies - A discussion of error sources

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Water displacement leg volumetry is a highly reproducible method, allowing the confirmation of efficacy of vasoactive substances. Nevertheless errors of its execution and the selection of unsuitable patients are likely to negatively affect the outcome of clinical studies in chronic venous insufficiency (CVI).</p> <p>Discussion</p> <p>Placebo controlled double-blind drug studies in CVI were searched (Cochrane Review 2005, MedLine Search until December 2007) and assessed with regard to efficacy (volume reduction of the leg), patient characteristics, and potential methodological error sources. Almost every second study reported only small drug effects (≀ 30 mL volume reduction). As the most relevant error source the conduct of volumetry was identified. Because the practical use of available equipment varies, volume differences of more than 300 mL - which is a multifold of a potential treatment effect - have been reported between consecutive measurements. Other potential error sources were insufficient patient guidance or difficulties with the transition from the Widmer CVI classification to the CEAP (Clinical Etiological Anatomical Pathophysiological) grading.</p> <p>Summary</p> <p>Patients should be properly diagnosed with CVI and selected for stable oedema and further clinical symptoms relevant for the specific study. Centres require a thorough training on the use of the volumeter and on patient guidance. Volumetry should be performed under constant conditions. The reproducibility of short term repeat measurements has to be ensured.</p

    Validity and reliability of a novel 3D scanner for assessment of the shape and volume of amputees’ residual limb models

    Get PDF
    Objective assessment methods to monitor residual limb volume following lower-limb amputation are required to enhance practitioner-led prosthetic fitting. Computer aided systems, including 3D scanners, present numerous advantages and the recent Artec Eva scanner, based on laser free technology, could potentially be an effective solution for monitoring residual limb volumes. The aim of this study was to assess the validity and reliability of the Artec Eva scanner (practical measurement) against a high precision laser 3D scanner (criterion measurement) for the determination of residual limb model shape and volume. Three observers completed three repeat assessments of ten residual limb models, using both the scanners. Validity of the Artec Eva scanner was assessed (mean percentage error <2%) and Bland-Altman statistics were adopted to assess the agreement between the two scanners. Intra and inter-rater reliability (repeatability coefficient <5%) of the Artec Eva scanner was calculated for measuring indices of residual limb model volume and shape (i.e. residual limb cross sectional areas and perimeters). Residual limb model volumes ranged from 885 to 4399 ml. Mean percentage error of the Artec Eva scanner (validity) was 1.4% of the criterion volumes. Correlation coefficients between the Artec Eva and the Romer determined variables were higher than 0.9. Volume intra-rater and inter-rater reliability coefficients were 0.5% and 0.7%, respectively. Shape percentage maximal error was 2% at the distal end of the residual limb, with intra-rater reliability coefficients presenting the lowest errors (0.2%), both for cross sectional areas and perimeters of the residual limb models. The Artec Eva scanner is a valid and reliable method for assessing residual limb model shapes and volumes. While the method needs to be tested on human residual limbs and the results compared with the current system used in clinical practice, it has the potential to quantify shape and volume fluctuations with greater resolution

    De bhagavadgītā : Nederlandse vertaling en enkele hoofdstukken, beschouwingen /

    No full text
    Academisch proefschrift ter verkrijging van de graad van Doctor in de Letteren en wijsbegeerteScharpé, Adriaa

    Friedrich Disease

    No full text
    • 

    corecore