25 research outputs found

    Detection of involved margins in breast specimens with X-ray phase-contrast computed tomography.

    Get PDF
    Margins of wide local excisions in breast conserving surgery are tested through histology, which can delay results by days and lead to second operations. Detection of margin involvement intraoperatively would allow the removal of additional tissue during the same intervention. X-ray phase contrast imaging (XPCI) provides soft tissue sensitivity superior to conventional X-rays: we propose its use to detect margin involvement intraoperatively. We have developed a system that can perform phase-based computed tomography (CT) scans in minutes, used it to image 101 specimens approximately half of which contained neoplastic lesions, and compared results against those of a commercial system. Histological analysis was carried out on all specimens and used as the gold standard. XPCI-CT showed higher sensitivity (83%, 95% CI 69-92%) than conventional specimen imaging (32%, 95% CI 20-49%) for detection of lesions at margin, and comparable specificity (83%, 95% CI 70-92% vs 86%, 95% CI 73-93%). Within the limits of this study, in particular that specimens obtained from surplus tissue typically contain small lesions which makes detection more difficult for both methods, we believe it likely that the observed increase in sensitivity will lead to a comparable reduction in the number of re-operations

    Detection of involved margins in breast specimens with x-ray phase-contrast computed tomography

    Get PDF
    Margins of wide local excisions in breast conserving surgery are tested through histology, which can delay results by days and lead to second operations. Detection of margin involvement intraoperatively would allow the removal of additional tissue during the same intervention. X-ray phase contrast imaging (XPCI) provides soft tissue sensitivity superior to conventional X-rays: we propose its use to detect margin involvement intraoperatively. We have developed a system that can perform phase-based computed tomography (CT) scans in minutes, used it to image 101 specimens approximately half of which contained neoplastic lesions, and compared results against those of a commercial system. Histological analysis was carried out on all specimens and used as the gold standard. XPCI-CT showed higher sensitivity (83%, 95% CI 69–92%) than conventional specimen imaging (32%, 95% CI 20–49%) for detection of lesions at margin, and comparable specificity (83%, 95% CI 70–92% vs 86%, 95% CI 73–93%). Within the limits of this study, in particular that specimens obtained from surplus tissue typically contain small lesions which makes detection more difficult for both methods, we believe it likely that the observed increase in sensitivity will lead to a comparable reduction in the number of re-operations

    Volumetric high-resolution X-ray phase-contrast virtual histology of breast specimens with a compact laboratory system

    Get PDF
    The assessment of margin involvement is a fundamental task in breast conserving surgery to prevent recurrences and reoperations. It is usually performed through histology, which makes the process time consuming and can prevent the complete volumetric analysis of large specimens. X-ray phase contrast tomography combines high resolution, sufficient penetration depth and high soft tissue contrast, and can therefore provide a potential solution to this problem. In this work, we used a high-resolution implementation of the edge illumination X-ray phase contrast tomography based on "pixel-skipping" X-ray masks and sample dithering, to provide high definition virtual slices of breast specimens. The scanner was originally designed for intra-operative applications in which short scanning times were prioritised over spatial resolution; however, thanks to the versatility of edge illumination, high-resolution capabilities can be obtained with the same system simply by swapping x-ray masks without this imposing a reduction in the available field of view. This makes possible an improved visibility of fine tissue strands, enabling a direct comparison of selected CT slices with histology, and providing a tool to identify suspect features in large specimens before slicing. Combined with our previous results on fast specimen scanning, this works paves the way for the design of a multi-resolution EI scanner providing intra-operative capabilities as well as serving as a digital pathology system

    Intra-Operative Assessment of Cancer with X-Ray Phase Contrast Computed Tomography

    Get PDF
    X-ray Phase-Contrast Computed Tomography (PC-CT) increases contrast in weakly attenuating samples, such as soft tissues. In Edge-Illumination (EI) PC-CT, phase effects are accessed from amplitude modulation of the x-ray beam using alternating transmitting and attenuating masks placed prior to the sample and detector. A large field of view PC-CT scanner using this technique was applied to two areas of cancer assessment, namely excised breast and esophageal tissue. For the breast tissue, Wide Local Excisions (WLEs) were studied intra-operatively using PC-CT for the evaluation of tumor removal in breast conservation surgery. Images were acquired in 10 minutes without compromising on image quality, showing this can be used in a clinical setting. Longer, higher resolution PC-CT images were also taken, with analysis showing previously undetected thinning of tumor strands. This would allow a second use of the system for “virtual histopathology”, outside of surgery. For the esophagus samples, tissues were taken from esophagectomy surgery, where the lower part of the esophagus is removed, and the stomach relocated. For the assessment of ongoing therapy, accurate staging of tumors in the removed esophagus is essential, with the current gold standard provided by histopathology. PCCT images were acquired on several samples and compare well with histopathology, with both modalities showing similar features. Examples are shown where staging of tumor penetration is possible with PC-CT images alone, which is hoped will be an important step in performing the imaging and staging intra-operatively

    Laboratory-based x-ray phase contrast CT technology for clinical intra-operative specimen imaging

    Get PDF
    The design of an X-ray phase contrast tomography system for intra-operative specimen imaging based on edge illumination is presented. The use of edge illumination makes possible working with large focus, polychromatic X-ray sources reducing acquisition times of tomography scans down to values compatible with clinical use, while maintaining phase sensitivity in a compact device. The results collected so far show that application of this technology to breast conservation surgery has great potential to reduce re-operations, thus saving additional costs for healthcare services and stress for patients

    Does Reader Performance with Digital Breast Tomosynthesis Vary according to Experience with Two-dimensional Mammography?

    Get PDF
    Purpose To assess whether individual reader performance with digital breast tomosynthesis (DBT) and two-dimensional (2D) mammography varies with number of years of experience or volume of 2D mammograms read. Materials and Methods After written informed consent was obtained, 8869 women (age range, 29-85 years; mean age, 56 years) were recruited into the TOMMY trial (A Comparison of Tomosynthesis with Digital Mammography in the UK National Health Service Breast Screening Program), an ethically approved, multicenter, multireader, retrospective reading study, between July 2011 and March 2013. Each case was read prospectively for clinical assessment and to establish ground truth. A retrospective reading data set of 7060 cases was created and randomly allocated for independent blinded review of (a) 2D mammograms, (b) DBT images and 2D mammograms, and (c) synthetic 2D mammograms and DBT images, without access to previous examinations. Readers (19 radiologists, three advanced practitioner radiographers, and two breast clinicians) who had 3-25 (median, 10) years of experience in the U.K. National Health Service Breast Screening Program and read 5000-13 000 (median, 8000) cases per annum were included in this study. Specificity was analyzed according to reader type and years and volume of experience, and then both specificity and sensitivity were analyzed by matched inference. The median duration of experience (10 years) was used as the cutoff point for comparison of reader performance. Results Specificity improved with the addition of DBT for all readers. This was significant for all staff groups (56% vs 68% and 49% vs 67% [P < .0001] for radiologists and advanced practitioner radiographers, respectively; 46% vs 55% [P = .02] for breast clinicians). Sensitivity was improved for 19 of 24 (79%) readers and was significantly higher for those with less than 10 years of experience (91% vs 86%; P = .03) and those with total mammographic experience of fewer than 80 000 cases (88% vs 86%; P = .03). Conclusion The addition of DBT to conventional 2D screening mammography improved specificity for all readers, but the gain in sensitivity was greater for readers with less than 10 years of experience.Study supported by National Institute for Health Research Health Technology Assessment Programme (09/22/182)

    Nutrient depletion in Bacillus subtilis biofilms triggers matrix production

    No full text
    Many types of bacteria form colonies that grow into physically robust and strongly adhesive aggregates known as biofilms. A distinguishing characteristic of bacterial biofilms is an extracellular polymeric substance (EPS) matrix that encases the cells and provides physical integrity to the colony. The EPS matrix consists of a large amount of polysaccharide, as well as protein filaments, DNA and degraded cellular materials. The genetic pathways that control the transformation of a colony into a biofilm have been widely studied, and yield a spatiotemporal heterogeneity in EPS production. Spatial gradients in metabolites parallel this heterogeneity in EPS, but nutrient concentration as an underlying physiological initiator of EPS production has not been explored. Here, we study the role of nutrient depletion in EPS production in Bacillus subtilis biofilms. By monitoring simultaneously biofilm size and matrix production, we find that EPS production increases at a critical colony thickness that depends on the initial amount of carbon sources in the medium. Through studies of individual cells in liquid culture we find that EPS production can be triggered at the single-cell level by reducing nutrient concentration. To connect the single-cell assays with conditions in the biofilm, we calculate carbon concentration with a model for the reaction and diffusion of nutrients in the biofilm. This model predicts the relationship between the initial concentration of carbon and the thickness of the colony at the point of internal nutrient deprivation. \ua9 2014 IOP Publishing and Deutsche Physikalische Gesellschaft

    Behavior of Long Carbon Fiber Reinforced Concrete Panels under Impact Loading

    No full text
    corecore