12 research outputs found

    Keck Planet Finder: design updates

    Get PDF
    The Keck Planet Finder (KPF) is a fiber-fed, high-resolution, high-stability spectrometer in development at the UC Berkeley Space Sciences Laboratory for the W.M. Keck Observatory. KPF is designed to characterize exoplanets via Doppler spectroscopy with a goal of a single measurement precision of 0.3 m s-1 or better, however its resolution and stability will enable a wide variety of astrophysical pursuits. Here we provide post-preliminary design review design updates for several subsystems, including: the main spectrometer, the fabrication of the Zerodur optical bench; the data reduction pipeline; fiber agitator; fiber cable design; fiber scrambler; VPH testing results and the exposure meter

    Keck Planet Finder: design updates

    Get PDF
    The Keck Planet Finder (KPF) is a fiber-fed, high-resolution, high-stability spectrometer in development at the UC Berkeley Space Sciences Laboratory for the W.M. Keck Observatory. KPF is designed to characterize exoplanets via Doppler spectroscopy with a goal of a single measurement precision of 0.3 m s-1 or better, however its resolution and stability will enable a wide variety of astrophysical pursuits. Here we provide post-preliminary design review design updates for several subsystems, including: the main spectrometer, the fabrication of the Zerodur optical bench; the data reduction pipeline; fiber agitator; fiber cable design; fiber scrambler; VPH testing results and the exposure meter

    Composition of Challenge Substance in Standardized Antimicrobial Efficacy Testing of Wound Antimicrobials Is Essential to Correctly Simulate Efficacy in the Human Wound Micro-Environment

    No full text
    Current standards insufficiently acknowledge the influence of the wound micro-environment on the efficacy of antimicrobial agents. To address this, octenidine/phenoxyethanol, polyhexanide, povidone-iodine, and sodium-hypochloride/hypochlorous acid solutions were submitted to standard-based (DIN-EN-13727) or modified peptide-based challenges and compared to a simulated clinical reference using human acute or chronic wound exudate (AWF/CWF). Antimicrobial efficacy against S. aureus and P. aeruginosa was compared using a quantitative suspension method. Agreement between methods were investigated using Bland-Altman (B&A) analysis. Different substances and challenges demonstrated diverging results, depending on class and concentration of agent and challenge. Highly concentrated antiseptics maintained a high efficacy under complex challenges, while especially chlorine-based irrigation solutions showed a remarkably reduced antimicrobial effect. Composition of challenge substance proved more relevant than pure concentration. Therefore, the current standard challenge conditions did not adequately reflect the wound micro-environment with over- or under-estimating antimicrobial efficacy, whilst the modified peptide-challenge showed a higher level of agreement with simulated realistic conditions (AWF/CWF). The results emphasize that a “one-fits-all” approach is not feasible to generalize antimicrobial efficacy, as certain aspects of the complex micro-environment pose a differing influence on varying agents. Based on these results, revision and target focused adaptation of the current standards should be considered

    Comparison of hemostatic dressings for superficial wounds using a new spectrophotometric coagulation assay

    Get PDF
    Background: Due to demographical changes the number of elderly patients depending on oral anticoagulation is expected to rise. Prolonged bleeding times in case of traumatic injuries represent the drawback of these medications, not only in major trauma, but also in superficial wounds. Therefore, dressings capable of accelerating coagulation onset and shortening bleeding times are desirable for these patients. Methods: The hemostatic potential and physical properties of different types of superficial wound dressings (standard wound pad, two alginates, chitosan, collagen (Lyostypt (R)), oxidized cellulose, and QuikClot (R)) were assessed in vitro. For this purpose the clotting times of blood under the influence of the named hemostatics from healthy volunteers were compared with Marcumar (R) or ASS (R) treated patients. For that, a newly developed coagulation assay based on spectrophotometric extinction measurements of thrombin activity was used. Results: The fastest coagulation onset was observed for oxidized cellulos (empty set 2.47 min), Lantor alginate-L (empty set 2.50 min) and QuikClot (R) (empty set 3.01 min). Chitosan (empty set 5.32 min) and the collagen Lyostypt (R) (empty set 7.59 min) induced clotting comparatively late. Regarding physical parameters, QuikClot (R) showed the lowest absorption capacity and speed while chitosan and both alginates achieved the highest. While oxidized cellulose displayed the best clotting times, unfortunately it also revealed low absorption capacity. Conclusions: All tested specimens seem to induce clotting independently from the administered type of oral anticoagulant, providing the possibility to neglect the disadvantage in clotting times arising from anticoagulation on a local basis. QuikClot (R), oxidized cellulose and unexpectedly alginate-L were superior to chitosan and Lyostypt (R). Due to its additional well-known positive effect on wound healing alginate-L should be considered for further investigations
    corecore