3,759 research outputs found

    Properties of axicon systems for collecting foil-excited accelerator beam spectra

    Get PDF
    Axicon system properties for collecting foil-excited accelerator beam spectr

    Correlated versus Ferromagnetic State in Repulsively Interacting Two-Component Fermi Gases

    Full text link
    Whether a spin-1/2 Fermi gas will become ferromagnetic as the strength of repulsive interaction increases is a long-standing controversial issue. Recently this problem is studied experimentally by Jo et al, Science, 325, 1521 (2009) in which the authors claim a ferromagnetic transition is observed. This work is to point out the results of this experiment can not distinguish whether the system is in a ferromagnetic state or in a non-magnetic but strongly short-range correlated state. A conclusive experimental demonstration of ferromagnetism relies on the observation of ferromagnetic domains.Comment: 4 pages, 2 figures, published versio

    Joining refractory/austenitic bimetal tubing Supplemental report

    Get PDF
    Joining bimetal tubing consisting of austenitic stainless steel with inner lining of niobium or tantalu

    Holocene Sediment Magnetic Properties Along a Transect from Isafjardardjup to Djupall, Northwest Iceland

    Full text link
    Holocene changes in terrestrial provenance and processes of sediment transport and deposition are tracked along a fjord-to-shelf transect adjacent to Vestfirdir, Iceland, using the magnetic properties ofmarine sediments.Magnetic susceptibility (MS) profiles of 10 cores (gravity and piston) were obtained onboard using a Bartington MS loop. Remanent magnetizations were measured at 1-cm intervals from u-channel samples taken from six cores on a cryogenic magnetometer. Between six and nine alternating field demagnetization steps were used to isolate the characteristic magnetization directions. The chronologies of the cores used in this study were determined from AMS14 C dates on mollusks and foraminifera and contrained by the regional occurrance ofthe 10,200 6 60 cal yr. BP Saksunavatn tepha. Correlative fluctuations in magneticconcentration are noted between the fjord and shelf sites, though these fluctuations are partiallymasked by regional variations in carbonate content. The onset of Neoglaciation is interpreted by changes in magnetic properties including an increase in mass magneticsusceptibility that began approximately 3000 cal yr. BP. The maximum angular deviation and the median destructive field (generally 20 mT) suggest that the natural remanent magnetization is carried by a coarse ferrimagnetite mineralogy, likely magnetite or titano-magnetite. Reproducible paleomagnetic inclination values are observed in several records, including a nearly vertical inclination around 8000 cal yr. BP, suggesting that the magnetic pole may have been proximal to Iceland, followed by an interval of much shallower inclination (6000–7000 cal yr. BP)

    Preliminary design study of hydrogen and ammonia resistojets for prime and auxiliary thrusters

    Get PDF
    Designs of high performance resistojets for primary and auxiliary propulsion are described.Thruster power for the primary propulsion application was in the 2 to 3 kW range while auxiliary propulsion power per thruster was 0.15 to 0.25 kW. Propellants considered were hydrogen and ammonia. The report described design techniques used to forecast the temperature and energy flux distributions using mathematical modeling by personal microcomputer. BASIC language is used throughout to give the designer rapid interaction and control. Both designs integrate compact first stage coils with concentric tubular heaters. The hybrid heater design allows better thruster power matching with the spacecraft power bus. Projected specific impulse levels were 760 to 830 s for hydrogen and 380 to 410 s for ammonia

    Pairing, Ferromagnetism, and Condensation of a normal spin-1 Bose gas

    Full text link
    We theoretically study the stability of a normal, spin disordered, homogenous spin-1 Bose gas against ferromagnetism, pairing, and condensation through a Random Phase Approximation which includes exchange (RPA-X). Repulsive spin-independent interactions stabilize the normal state against both ferromagnetism and pairing, and for typical interaction strengths leads to a direct transition from an unordered normal state to a fully ordered single particle condensate. Atoms with much larger spin-dependent interaction may experience a transition to a ferromagnetic normal state or a paired superfluid, but, within the RPA-X, there is no instability towards a normal state with spontaneous nematic order. We analyze the role of the quadratic Zeeman effect and finite system size.Comment: 4 pages, 3 figures, 1 table. Supplementary materials attache

    A design study of hydrazine and biowaste resistojets

    Get PDF
    A generalized modeling program was adapted in BASIC on a personal computer to compare the performance of four types of biowaste resistojets and two types of hydrazine augmenters. Analyzed biowaste design types were: (1) an electrically conductive ceramic heater-exchanger of zirconia; (2) a truss heater of platinum in cross flow; (3) an immersed bicoiled tubular heater-exchanger; and (4) a nonexposed, refractory metal, radiant heater in a central cavity within a heat exchanger case. Concepts 2 and 3 are designed to have an efficient, stainless steel outer pressure case. The hydrazine design types are: (5) an immersed bicoil heater exchanger and (6) a nonexposed radiant heater now with a refractory metal case. The ceramic biowaste resistojet has the highest specific impulse growth potential at 2000 K of 192.5 (CO2) and 269 s (H2O). The bicoil produces the highest augmenter temperature of 1994 K for a 2073 K heater giving 317 s at .73 overall efficiency. Detailed temperature profiles of each of the designs are shown. The scaled layout drawings of each are presented with recommended materials and fabrication methods

    Intravenous versus subcutaneous drug administration. Which do patients prefer? A systematic review

    Get PDF
    BACKGROUND: Intravenous (IV) drug delivery is commonly used for its rapid administration and immediate drug effect. Most studies compare IV to subcutaneous (SC) delivery in terms of safety and efficacy, but little is known about what patients prefer. METHODS: A systematic review was conducted by searching seven electronic databases for articles published up to February 2014. Included studies were randomized controlled trials (RCTs) and/or crossover designs investigating patient preference for SC versus IV administration. The risk of bias in the RCTs was determined using the Cochrane Collaboration tool. Reviewers independently extracted data and assessed the risk of bias. Any discrepancies were resolved by consensus. RESULTS: The search identified 115 publications, but few (6/115) met the inclusion criteria. Patient populations and drugs investigated were diverse. Four of six studies demonstrated a clear patient preference for SC administration. Main factors associated with SC preference were time saving and the ability to have treatment at home. Only three studies used study-specific instruments to measure preference. CONCLUSIONS: Results suggest that patients prefer SC over IV delivery. Patient preference has clearly been neglected in clinical research, but it is important in medical decision making when choosing treatment methods as it has implications for adherence and quality of life. If the safety and efficacy of both administration routes are equivalent, then the most important factor should be patient preference as this will ensure optimal treatment adherence and ultimately improve patient experience or satisfaction. Future drug efficacy and safety studies should include contemporaneous, actual patient preference where possible, utilizing appropriate measures

    Determining density of maize canopy. 2: Airborne multispectral scanner data

    Get PDF
    Multispectral scanner data were collected in two flights over a light colored soil background cover plot at an altitude of 305 m. Energy in eleven reflective wavelength band from 0.45 to 2.6 microns was recorded. Four growth stages of maize (Zea mays L.) gave a wide range of canopy densities for each flight date. Leaf area index measurements were taken from the twelve subplots and were used as a measure of canopy density. Ratio techniques were used to relate uncalibrated scanner response to leaf area index. The ratios of scanner data values for the 0.72 to 0.92 micron wavelength band over the 0.61 to 0.70 micron wavelength band were calculated for each plot. The ratios related very well to leaf area index for a given flight date. The results indicated that spectral data from maize canopies could be of value in determining canopy density

    Comparing soil boundaries delineated by digital analysis of multispectral scanner data from high and low spatial resolution systems

    Get PDF
    The author has identified the following significant results. Computer-aided analysis techniques used with aircraft MSS data showed that the spatial resolution was sufficient to recognize each soil mapping unit of the test site. Some difficulties occurred where different soil series were intricately mixed, and this mixture showed as a separate spectral mapping unit, or where the difference between two soils depended on the depth of silty surface material. Analysis of LANDSAT data with computer-aided techniques showed that it was not possible to find spectrally homogeneous soil features of the seven soil series on the 40 ha test site on the digital display or on a picture print map. Cluster techniques could be used on an extended test area to group spectrally similar data points into cluster classes
    • …
    corecore