2 research outputs found

    Racism and Patriarchy in the Meaning of Motherhood

    Get PDF
    The catalytic abilities of a gold electrode were tested for the quantitative determination of amphetamine (A) and 3,4-methylenedioxy-N-methylamphetamine (MDMA) standards by their oxidation using cyclic voltammetry (CV). The values of the oxidative currents of A and MDMA standards at 0.80 V vs. SCE in 0.05 M NaHCO3 at a scan rate of 50 mV s-1 were linear functions of the concentration in range of 110.9-258.9 μM and 38.7-229.2 μM, respectively. Square wave voltammetry (SWV) revealed a linear increase of current with the concentration of MDMA (range 30.9-91.6 μM), which enabled the quantitative determination of amphetamine derivates. SWV analysis was also successfully performed in spiked urine samples. A and MDMA in the presence of sucrose and as a content in illegally produced tablets were also determined. The voltammetric determinations of A and MDMA derivatives using CV and SWV at gold a electrode are rapid, selective and simple procedures and their accuracy was confirmed with a reference method, high performance liquid chromatography (HPLC). The analysis of spiked urine samples offers an additional possibility for the rapid detection of A and MDMA in human urine.Katalitička svojstva elektrode od zlata su testirana za kvantitativno određivanje amfetamina (A) i 3,4-metilendioksi-N-metilamfetamina (MDMA) standarda. Elektroksidacija A i MDMA je praćena cikličnom voltametrijom (CV). Vrednost oksidativnog pika A i MDMA standarda je linearna funkcija koncentracija u opsegu 110,9-258,9 μM (A) i 38,7-229,2 μM (MDMA). Voltametrija sa pravougaonim impulsima (SWV) je pokazala linearnu zavisnost struja od koncentracija za MDMA standard (u opsegu: 30,9-91,6 μM) kao i u spajkovanim uzorcima humanog urina. Uspešno je analiziran i sadržaj A i MDMA u ilegalno proizvedenim tabletama. Voltametrijsko određivanje A i MDMA derivata uz pomoć CV i SWV na elektrodi od zlata je brza, selektivna i jednostavna procedura. Analiza spajkovanih uzoraka urina nudi dodatnu mogućnost za brzu detekciju A i MDMA u humanom urinu

    The use of a gold electrode for the determination of amphetamine derivatives and application to their analysis in human urine

    No full text
    The catalytic abilities of gold electrode were tested for the quantitative determination of amphetamine (A) and 3,4-methylenedioxy-N-methylamphetamine (MDMA) standards by their oxidation using cyclic voltammetry (CV). The value of the oxidative currents of A and MDMA standards at 0.80 V vs. SCE in 0.05 M NaHCO3 at the scan rate of 50 mV/s is linear function of concentration in range of 110.9-258.9 mM and 38.7-229.2 mM, respectively. Square wave voltammetry (SWV) revealed linear increase of current with concentration of MDMA (range 30.9-91.6 mM) and thus quantitative determination of amphetamine derivates. SWV analysis is successfully performed in spiked urine samples as well. A and MDMA in the presence of sucrose and as a content in illegally produced tablets were also analyzed. The voltammetric determination of A and MDMA derivatives using CV and SWV at gold electrode is a rapid, selective and simple procedure and its accuracy was confirmed with reference method, high performance liquid chromatography (HPLC). The spiked urine samples analysis offers additional possibility for the rapid detection of A and MDMA in human urine
    corecore