The influence of vibration transducer mounting on the practical measurement of railway vibration
When assessing ground-borne vibration related to railways, careful consideration needs to be given to the mounting and coupling of the transducers. This paper presents the results of research investigating some of these fundamental issues. Different couplant materials and
four of the most commonly used transducer-to-ground coupling techniques (spikes, buried,
slabs, and the transducer directly plastered to the ground), were compared and analysed
within the frequency range 5 Hz to 500 Hz.
The data demonstrate that transducer vertical alignment has limited influence at small angles. āBlu-tackā showed to be an adequate couplant. Above 50 Hz coupling systems can influence the reading by up to 20 dB. Using the train as a source of vibration yields a high degree of non-linearity on the coupling systems performance
Issues and limitations on measuring buildingās transfer function
In the planning stages for new buildings or transit systems, the effects of railway induced
ground-borne vibration need to be considered. The propagation of vibration from the ground
to a receiving room is a complex problem. It is common practise, within vibration assessment,
for the buildings vibration response to be acquired empirically by ether measuring the
response of the building in question via an impact method, measuring the response on an
equivalent type of building, or using pre existing published data (from the 70s and 80s) to
derive a ground to building transfer functions. This paper compares, as a method of evaluating
a building transfer function, impact method with actual rail pass-bys and recently collected
response with published generalised response curves. The results presented suggests that,
when using the impact method excitation process (point source), the distance of impact
location to the building foundation is critical, drastically affecting the resulting transfer
function. In addition when using train pass-bys as the excitation process, train length is shown
to have an influence on the transfer function assessed. The pre-published data are also shown
to have limitations for more recent types of construction
Procedures for estimating environmental impact from railway induced vibration: a review
Railway induced ground-borne vibration is among the most
common and widespread sources of perceptible environmental
vibration. It can give rise to discomfort and disturbance,
adversely impacting on human activity and the operation of
sensitive equipment. The rising demand for building new
railway lines or upgrading existing lines in order to meet
increasing transit flows has furthered the need for adequate
vibration assessment tools during the planning and design
stages. In recent years many studies in the fields of rail and
ground dynamics have encouraged many prediction techniques
giving rise to a wide variety of procedures for estimating
vibration on buildings. Each method shows potential for
application at different levels of complexity and applicability to
varying circumstances. From the perspective of railway
environmental impact assessment, this paper reviews some
relevant prediction techniques, assessing their degree of
suitability for practical engineering application by weighting
their methodology (i.e. considerations and requirements) against
practicality and precision. The review suggests that not all
procedures are practicable (e.g. the attainment of representative
parameters needed to run the procedures) whilst others
predicate on assumptions which revealed to be too relaxed
resulting in insufficient accuracy; however, a combination of
methods may provide the necessary balance