40 research outputs found
The Role of Landscape Connectivity in Planning and Implementing Conservation and Restoration Priorities. Issues in Ecology
Landscape connectivity, the extent to which a landscape facilitates the movements of organisms and their genes, faces critical threats from both fragmentation and habitat loss. Many conservation efforts focus on protecting and enhancing connectivity to offset the impacts of habitat loss and fragmentation on biodiversity conservation, and to increase the resilience of reserve networks to potential threats associated with climate change. Loss of connectivity can reduce the size and quality of available habitat, impede and disrupt movement (including dispersal) to new habitats, and affect seasonal migration patterns. These changes can lead, in turn, to detrimental effects for populations and species, including decreased carrying capacity, population declines, loss of genetic variation, and ultimately species extinction. Measuring and mapping connectivity is facilitated by a growing number of quantitative approaches that can integrate large amounts of information about organisms’ life histories, habitat quality, and other features essential to evaluating connectivity for a given population or species. However, identifying effective approaches for maintaining and restoring connectivity poses several challenges, and our understanding of how connectivity should be designed to mitigate the impacts of climate change is, as yet, in its infancy. Scientists and managers must confront and overcome several challenges inherent in evaluating and planning for connectivity, including: •characterizing the biology of focal species; •understanding the strengths and the limitations of the models used to evaluate connectivity; •considering spatial and temporal extent in connectivity planning; •using caution in extrapolating results outside of observed conditions; •considering non-linear relationships that can complicate assumed or expected ecological responses; •accounting and planning for anthropogenic change in the landscape; •using well-defined goals and objectives to drive the selection of methods used for evaluating and planning for connectivity; •and communicating to the general public in clear and meaningful language the importance of connectivity to improve awareness and strengthen policies for ensuring conservation. Several aspects of connectivity science deserve additional attention in order to improve the effectiveness of design and implementation. Research on species persistence, behavioral ecology, and community structure is needed to reduce the uncertainty associated with connectivity models. Evaluating and testing connectivity responses to climate change will be critical to achieving conservation goals in the face of the rapid changes that will confront many communities and ecosystems. All of these potential areas of advancement will fall short of conservation goals if we do not effectively incorporate human activities into connectivity planning. While this Issue identifies substantial uncertainties in mapping connectivity and evaluating resilience to climate change, it is also clear that integrating human and natural landscape conservation planning to enhance habitat connectivity is essential for biodiversity conservation
Inactivation of Poxviruses by Upper-Room UVC Light in a Simulated Hospital Room Environment
In the event of a smallpox outbreak due to bioterrorism, delays in vaccination programs may lead to significant secondary transmission. In the early phases of such an outbreak, transmission of smallpox will take place especially in locations where infected persons may congregate, such as hospital emergency rooms. Air disinfection using upper-room 254 nm (UVC) light can lower the airborne concentrations of infective viruses in the lower part of the room, and thereby control the spread of airborne infections among room occupants without exposing occupants to a significant amount of UVC. Using vaccinia virus aerosols as a surrogate for smallpox we report on the effectiveness of air disinfection, via upper-room UVC light, under simulated real world conditions including the effects of convection, mechanical mixing, temperature and relative humidity. In decay experiments, upper-room UVC fixtures used with mixing by a conventional ceiling fan produced decreases in airborne virus concentrations that would require additional ventilation of more than 87 air changes per hour. Under steady state conditions the effective air changes per hour associated with upper-room UVC ranged from 18 to 1000. The surprisingly high end of the observed range resulted from the extreme susceptibility of vaccinia virus to UVC at low relative humidity and use of 4 UVC fixtures in a small room with efficient air mixing. Increasing the number of UVC fixtures or mechanical ventilation rates resulted in greater fractional reduction in virus aerosol and UVC effectiveness was higher in winter compared to summer for each scenario tested. These data demonstrate that upper-room UVC has the potential to greatly reduce exposure to susceptible viral aerosols. The greater survival at baseline and greater UVC susceptibility of vaccinia under winter conditions suggest that while risk from an aerosol attack with smallpox would be greatest in winter, protective measures using UVC may also be most efficient at this time. These data may also be relevant to influenza, which also has improved aerosol survival at low RH and somewhat similar sensitivity to UVC
A study of indoor carbon dioxide levels and sick leave among office workers
BACKGROUND: A previous observational study detected a strong positive relationship between sick leave absences and carbon dioxide (CO(2)) concentrations in office buildings in the Boston area. The authors speculated that the observed association was due to a causal effect associated with low dilution ventilation, perhaps increased airborne transmission of respiratory infections. This study was undertaken to explore this association. METHODS: We conducted an intervention study of indoor CO(2) levels and sick leave among hourly office workers employed by a large corporation. Outdoor air supply rates were adjusted periodically to increase the range of CO(2) concentrations. We recorded indoor CO(2) concentrations every 10 minutes and calculated a CO(2) concentration differential as a measure of outdoor air supply per person by subtracting the 1–3 a.m. average CO(2) concentration from the same-day 9 a.m. – 5 a.m. average concentration. The metric of CO(2) differential was used as a surrogate for the concentration of exhaled breath and for potential exposure to human source airborne respiratory pathogens. RESULTS: The weekly mean, workday, CO(2) concentration differential ranged from 37 to 250 ppm with a peak CO(2) concentration above background of 312 ppm as compared with the American Society of Heating, Refrigeration and Air-conditioning Engineers (ASHRAE) recommended maximum differential of 700 ppm. We determined the frequency of sick leave among 294 hourly workers scheduled to work approximately 49,804.2 days in the study areas using company records. We found no association between sick leave and CO(2) differential CONCLUSIONS: The CO(2) differential was in the range of very low values, as compared with the ASHRAE recommended maximum differential of 700 ppm. Although no effect was found, this study was unable to test whether higher CO(2) differentials may be associated with increased sick leave
Airborne rhinovirus detection and effect of ultraviolet irradiation on detection by a semi-nested RT-PCR assay
BACKGROUND: Rhinovirus, the most common cause of upper respiratory tract infections, has been implicated in asthma exacerbations and possibly asthma deaths. Although the method of transmission of rhinoviruses is disputed, several studies have demonstrated that aerosol transmission is a likely method of transmission among adults. As a first step in studies of possible airborne rhinovirus transmission, we developed methods to detect aerosolized rhinovirus by extending existing technology for detecting infectious agents in nasal specimens. METHODS: We aerosolized rhinovirus in a small aerosol chamber. Experiments were conducted with decreasing concentrations of rhinovirus. To determine the effect of UV irradiation on detection of rhinoviral aerosols, we also conducted experiments in which we exposed aerosols to a UV dose of 684 mJ/m(2). Aerosols were collected on Teflon filters and rhinovirus recovered in Qiagen AVL buffer using the Qiagen QIAamp Viral RNA Kit (Qiagen Corp., Valencia, California) followed by semi-nested RT-PCR and detection by gel electrophoresis. RESULTS: We obtained positive results from filter samples that had collected at least 1.3 TCID(50 )of aerosolized rhinovirus. Ultraviolet irradiation of airborne virus at doses much greater than those used in upper-room UV germicidal irradiation applications did not inhibit subsequent detection with the RT-PCR assay. CONCLUSION: The air sampling and extraction methodology developed in this study should be applicable to the detection of rhinovirus and other airborne viruses in the indoor air of offices and schools. This method, however, cannot distinguish UV inactivated virus from infectious viral particles
Institutional tuberculosis transmission : controlled trial of upper room ultraviolet air disinfection : a basis for new dosing guidelines
RATIONALE : Transmission is driving the global tuberculosis epidemic,
especially in congregate settings. Worldwide, natural ventilation is
the most common means of air disinfection, but it is inherently
unreliable and of limited use in cold climates. Upper room germicidal
ultraviolet (UV) air disinfection with air mixing has been shown to be
highly effective, but improved evidence-based dosing guidelines are
needed.
OBJECTIVES : To test the efficacy of upper room germicidal
air disinfection with air mixing to reduce tuberculosis
transmission under real hospital conditions, and to define the
application parameters responsible as a basis for proposed new
dosing guidelines.
METHODS : Over an exposure period of 7 months, 90 guinea pigs
breathed only untreated exhaust ward air, and another 90 guinea pigs
breathed only air from the same six-bed tuberculosis ward on alternate days when upper room germicidal air disinfection was
turned on throughout the ward.
MEASUREMENTS AND MAIN RESULTS : The tuberculin skin test
conversion rates (.6 mm) of the two chambers were compared. The
hazard ratio for guinea pigs in the control chamber converting their
skin test to positive was 4.9 (95% confidence interval, 2.8–8.6), with
an efficacy of approximately 80%.
CONCLUSIONS : Upper room germicidal UV air disinfection with air
mixing was highly effective in reducing tuberculosis transmission
under hospital conditions. These data support using either a total
fixture output (rather than electrical or UV lamp wattage) of
15–20 mW/m3 total room volume, or an average whole-room UV
irradiance (fluence rate) of 5–7 mW/cm2, calculated by a lighting
computer-assisted design program modified for UV use.http://www.atsjournals.org/journal/ajrccm2016-08-31hb201
Lead optimization of a pyrazole sulfonamide series of trypanosoma brucei N -myristoyltransferase inhibitors:Identification and evaluation of CNS penetrant compounds as potential treatments for stage 2 human african trypanosomiasis
[Image: see text] Trypanosoma bruceiN-myristoyltransferase (TbNMT) is an attractive therapeutic target for the treatment of human African trypanosomiasis (HAT). From previous studies, we identified pyrazole sulfonamide, DDD85646 (1), a potent inhibitor of TbNMT. Although this compound represents an excellent lead, poor central nervous system (CNS) exposure restricts its use to the hemolymphatic form (stage 1) of the disease. With a clear clinical need for new drug treatments for HAT that address both the hemolymphatic and CNS stages of the disease, a chemistry campaign was initiated to address the shortfalls of this series. This paper describes modifications to the pyrazole sulfonamides which markedly improved blood–brain barrier permeability, achieved by reducing polar surface area and capping the sulfonamide. Moreover, replacing the core aromatic with a flexible linker significantly improved selectivity. This led to the discovery of DDD100097 (40) which demonstrated partial efficacy in a stage 2 (CNS) mouse model of HAT