45 research outputs found

    Prevalence of RT-qPCR-detected SARS-CoV-2 infection at schools: First results from the Austrian School-SARS-CoV-2 prospective cohort study.

    Get PDF
    BACKGROUND: The role of schools in the SARS-CoV-2 pandemic is much debated. We aimed to quantify reliably the prevalence of SARS-CoV-2 infections at schools detected with reverse-transcription quantitative polymerase-chain-reaction (RT-qPCR). METHODS: This nationwide prospective cohort study monitors a representative sample of pupils (grade 1-8) and teachers at Austrian schools throughout the school year 2020/2021. We repeatedly test participants for SARS-CoV-2 infection using a gargling solution and RT-qPCR. We herein report on the first two rounds of examinations. We used mixed-effects logistic regression to estimate odds ratios and robust 95% confidence intervals (95% CI). FINDINGS: We analysed data on 10,734 participants from 245 schools (9465 pupils, 1269 teachers). Prevalence of SARS-CoV-2 infection increased from 0·39% at round 1 (95% CI 028-0·55%, 28 September-22 October 2020) to 1·39% at round 2 (95% CI 1·04-1·85%, 10-16 November). Odds ratios for SARS-CoV-2 infection were 2·26 (95% CI 1·25-4·12, P = 0·007) in regions with >500 vs. ≤500 inhabitants/km2, 1·67 (95% CI 1·42-1·97, P<0·001) per two-fold higher regional 7-day community incidence, and 2·78 (95% CI 1·73-4·48, P<0·001) in pupils at schools with high/very high vs. low/moderate social deprivation. Associations of regional community incidence and social deprivation persisted in a multivariable adjusted model. Prevalence did not differ by average number of pupils per class nor between age groups, sexes, pupils vs. teachers, or primary (grade 1-4) vs. secondary schools (grade 5-8). INTERPRETATION: This monitoring study in Austrian schools revealed SARS-CoV-2 infection in 0·39%-1·39% of participants and identified associations of regional community incidence and social deprivation with higher prevalence. FUNDING: BMBWF Austria

    Sensitivity and specificity of the antigen-based anterior nasal self-testing programme for detecting SARS-CoV-2 infection in schools, Austria, March 2021.

    Get PDF
    This study evaluates the performance of the antigen-based anterior nasal screening programme implemented in all Austrian schools to detect SARS-CoV-2 infections. We combined nationwide antigen-based screening data obtained in March 2021 from 5,370 schools (Grade 1-8) with an RT-qPCR-based prospective cohort study comprising a representative sample of 244 schools. Considering a range of assumptions, only a subset of infected individuals are detected with the programme (low to moderate sensitivity) and non-infected individuals mainly tested negative (very high specificity)

    Relationship between Endothelial Function, Antiretroviral Treatment and Cardiovascular Risk Factors in HIV Patients of African Descent in South Africa: A Cross-Sectional Study

    Get PDF
    Limited information on the effect of antiretroviral treatment (ART) on vascular function in South Africans of African descent living with human immunodeficiency virus (HIV) is available. The relationship between ART, vascular function and cardiovascular risk factors in South Africans of African ancestry with HIV was therefore studied. This cross-sectional study recruited 146 HIV-positive individuals on ART (HIV+ART+), 163 HIV-positive individuals not on ART (HIV+ART−) and 171 individuals without HIV (HIV−) in Mthatha, Eastern Cape Province of South Africa. Flow-mediated dilation (FMD) test was performed to assess endothelial function. Anthropometry and blood pressure parameters were measured. Lipid profile, glycaemic indices, serum creatinine as well as CD4 count and viral load were assayed in blood. Urinary albumin to creatinine ratio (ACR) was determined as a marker of cardiovascular risk. Obesity and albuminuria were positively associated with HIV, and HIV+ART+ participants had significantly higher HDL cholesterol. Dyslipidaemia markers were significantly higher in hypertensive HIV+ART+ participants compared with the controls (HIV+ART− and HIV− participants). FMD was not different between HIV+ART+ participants and the controls. Moreover, HIV+ART+ participants with higher FMD showed lower total cholesterol and LDL cholesterol comparable to that of HIV− and HIV+ART− participants. A positive relationship between FMD and CD4 count was observed in HIV+ART+ participants. In conclusion, antiretroviral treatment was associated with cardiovascular risk factors, particularly dyslipidaemia, in hypertensive South Africans of African ancestry with HIV. Although, ART was not associated with endothelial dysfunction, flow-mediated dilatation was positively associated with CD4 count in HIV-positive participants on ART

    Cardiovascular risk and endothelial function in people living with HIV/AIDS: design of the multi-site, longitudinal EndoAfrica study in the Western Cape Province of South Africa

    Get PDF
    CITATION: Strijdom, H., et al. 2017. Cardiovascular risk and endothelial function in people living with HIV/AIDS: design of the multi-site, longitudinal EndoAfrica study in the Western Cape Province of South Africa. BMC Infectious Diseases, 17:41, doi:10.1186/s12879-016-2158-y.The original publication is available at http://bmcinfectdis.biomedcentral.comBackground: There is growing evidence of an interaction between HIV-infection, anti-retroviral therapy (ART) and cardiovascular diseases (CVD). Epidemiological studies in Europe and North America have been observing a shift towards an increased incidence of coronary heart disease and acute myocardial infarctions in HIV-infected populations compared to the general population even after adjusting for traditional cardiovascular risk factors. Despite South Africa (and sub-Saharan Africa, SSA) being regarded as the epicentre of the global HIV epidemic, very little is known about the prevalence of cardiovascular risk factors and precursors of vascular disease in HIV-infected populations in this region. The knowledge gap is further widened by the paucity of data from prospective studies. We present the rationale, objectives and key methodological features of the EndoAfrica study, which aims to determine whether HIVinfection and ART are associated with altered cardiovascular risk and changes in vascular endothelial structure and function in adults living in the Western Cape Province of South Africa. Methods: In this longitudinal study, comprehensive cardiovascular assessments of HIV-negative and HIV-positive (with and without ART) study participants are performed by clinical and biochemical screening for traditional cardiovascular risk factors and biomarkers of CVD. Vascular and endothelial function is determined by brachial artery flow-mediated dilatation (FMD), carotid-intima-thickness (IMT) measurements and quantitative retinal blood vessel analyses, complemented by vascular endothelial biomarker assays. Finally, we aim to statistically determine whether HIVinfection and/or ART are associated with increased cardiovascular risk and vascular endothelial dysfunction, and determine whether there is progression/regression in these endpoints 18 months after the baseline assessments. Discussion: The EndoAfrica study provides a unique opportunity to recruit a cohort of HIV-infected patients and HIVnegative controls who will be comprehensively and longitudinally assessed for cardiovascular risk and disease profile with vascular endothelial function as a potentially important intermediate cardiovascular phenotype. To our knowledge, it is the first time that such a systematic study has been established in the context of SSA and South Africa.http://bmcinfectdis.biomedcentral.com/articles/10.1186/s12879-016-2158-yPublisher's versio

    Rapid Quantification of Hepatitis B Virus DNA by Automated Sample Preparation and Real-Time PCR

    No full text
    Monitoring of hepatitis B virus (HBV) DNA in serum by molecular methods has become the standard for assessment of the replicative activity of HBV. Several molecular assays for the detection and quantification of HBV DNA have been described. However, they usually lack automated sample preparation. Moreover, those assays, which are based on PCR, are limited by a short dynamic range (2 to 3 log units). In the present study, the use of RealArt HBV LC PCR Reagents in conjunction with automated extraction on the COBAS AMPLIPREP analyzer was evaluated. Members of an HBV proficiency program panel were tested; linearity, interassay, and intra-assay variations were determined. The performance of the assay in a routine clinical laboratory was evaluated with a total of 117 clinical specimens. When members of the HBV proficiency program panel were tested by the new molecular assay, the results were found to be within ±0.5 log unit of the results obtained by reference laboratories. Determination of linearity resulted in a quasilinear curve over more than 6 log units. The interassay variation of the RealArt HBV LC PCR Reagents by use of the automated sample preparation protocol ranged from 16 to 73%, and the intra-assay variation ranged from 9 to 40%. When clinical samples were tested by the new assay with the automated sample preparation protocol and the results were compared with those obtained by the COBAS AMPLICOR HBV MONITOR Test with manual sample preparation, the results for 76% of all samples with positive results by both tests were found to be within ±0.5 log unit and the results for another 18% were found to be within between 0.5 and 1.0 log unit. In conclusion, the real-time PCR assay with automated sample preparation proved to be suitable for the routine molecular laboratory and required less hands-on time

    Evaluation of Automated Sample Preparation and Quantitative PCR LCx Assay for Determination of Human Immunodeficiency Virus Type 1 RNA

    No full text
    Efforts have been made to achieve full automation of molecular assays for quantitative detection of human immunodeficiency virus type 1 (HIV-1). In the present study, the Abbott LCx HIV RNA Quantitative assay was evaluated in conjunction with automated HIV-1 RNA extraction on the MagNA Pure LC instrument and compared to the conventional LCx HIV RNA Quantitative assay, which uses a manual nucleic acid extraction protocol. Accuracy, linearity, and interassay and intra-assay variations were determined. The performance of the assay in a routine clinical laboratory was tested with a total of 105 clinical specimens. When the accuracy of the LCx HIV RNA Quantitative assay with the automated sample preparation protocol was tested, all results were found to be within ±0.5 log unit of the expected results. Determination of linearity resulted in a quasilinear curve over 3.5 log units. For determination of interassay variation, coefficients of variation were found to be between 21 and 66% for the LCx HIV RNA Quantitative assay with the automated sample preparation protocol and between 10 and 69% for the LCx HIV RNA Quantitative assay with manual sample preparation. For determination of intra-assay variation, coefficients of variation were found to be between 7 and 25% for the LCx HIV RNA Quantitative assay with the automated sample preparation protocol and between 7 and 19% for the LCx HIV RNA Quantitative assay with manual sample preparation. When clinical samples were tested by the LCx HIV RNA Quantitative assay with the automated sample preparation protocol and the results were compared with those of the LCx HIV RNA Quantitative assay with manual sample preparation, 95% of all positive results were found to be within ±0.5 log unit. In conclusion, the assay with automated sample preparation proved to be suitable for use in the routine diagnostic laboratory and required significantly less hands-on time

    SARS-CoV-2 RNA Testing Using Different Assays—Impact on Testing Strategies in a Clinical Setting

    No full text
    In order to assess SARS-CoV-2 real time quantitative polymerase chain reaction (RT-qPCR) results in a real-life setting, three independent laboratories in Graz (Austria) set up a continuous cross comparison schedule. The following test systems were used: The QIAGEN NeuMoDx SARS-CoV-2 Assay, the Allplex™ 2019-nCoV Assay (Seegene) on a MicroLab Nimbus (Hamilton) platform combined with RealStar SARS-CoV-2 RT-PCR Assay (Altona Diagnostics GmbH), and the cobas SARS-CoV-2 test on a fully automated cobas 6800 system (Roche). A total of 200 samples were analysed, 184 (92%) were found to be concordant with all testing platforms, 14 (7%) discordant. Two (1%) samples tested invalid on a single platform and were excluded from further analysis. Discordant results were distributed randomly across the assays. The Ct values from all assays correlated closely with each other. All discordant samples showed Ct values ≥ 26. SARS-CoV-2 RT-qPCR assays may show considerable variability, especially in samples with low viral RNA concentrations. Decision makers should thus balance the advantages and disadvantages of RT-qPCR for mass screening and adopt suitable strategies that ensure a rational management of positive samples with high Ct values
    corecore