5 research outputs found
Monte Carlo simulated beam quality and perturbation correction factors for ionization chambers in monoenergetic proton beams
Purpose Beam quality correction factors provided in current codes of practice for proton beams are approximated using the water-to-air mass stopping power ratio and by assuming the proton beam quality related perturbation correction factors to be unity. The aim of this work is to use Monte Carlo simulations to calculate energy dependent beam quality and perturbation correction factors for a set of nine ionization chambers in proton beams. Methods The Monte Carlo code EGSnrc was used to determine the ratio of the absorbed dose to water and the absorbed dose to the sensitive air volume of ionization chambersfQ0related to the reference photon beam quality (Co-60). For proton beams, the quantityfQwas simulated with GATE/Geant4 for five monoenergetic beam energies between 70 MeV and 250 MeV. The perturbation correction factors for the air cavity, chamber wall, chamber stem, central electrode, and displacement effect in proton radiation were investigated separately. Additionally, the correction factors of cylindrical chambers were investigated with and without consideration of the effective point of measurement. Results The perturbation factorspQwere shown to deviate from unity for the investigated chambers, contradicting the assumptions made in dosimetry protocols. The beam quality correction factors for both plane-parallel and cylindrical chambers positioned with the effective point of measurement at the measurement depth were constant within 0.8%. An increase of the beam quality correction factors determined for cylindrical ionization chambers placed with their reference point at the measurement depth with decreasing energy is attributed to the displacement perturbation correction factorspdis, which were up to 1.045 +/- 0.1% for the lowest energy and 1.005 +/- 0.1% for the highest energy investigated. Besidespdis, the largest perturbation was found for the chamber wall where the smallestpwalldetermined was 0.981 +/- 0.3%. Conclusions Beam quality correction factors applied in dosimetry with cylindrical chambers in monoenergetic proton beams strongly depend on the positioning method used. We found perturbation correction factors different from unity. Consequently, the approximation of ionization chamber perturbations in proton beams by the respective water-to-air mass stopping power ratio shall be revised
Usability and accuracy of high-resolution detectors for daily quality assurance for robotic radiosurgery
For daily CyberKnife QA a Winston-Lutz-Test (Automated-Quality-Assurance, AQA) is used to determine sub-millimeter deviations in beam delivery accuracy. This test is performed using gafchromic film, an extensive and user-dependent method requiring the use of disposables. We therefore analyzed the usability and accuracy of high-resolution detector arrays. We analyzed a liquid-filled ionization-chamber array (Octavius 1000SRS, PTW, Germany), which has a central resolution of 2.5mm. To test sufficient sensitivity, beam profiles with robot shifts of 0.1mm along the arrays' axes were measured. The detected deviation between the shifted and central profile were compared to the real robot's position. We then compared the results to the SRS-Profiler (SunNuclear, USA) with 4.0mm resolution and to the Nonius (QUART, Germany), a single-line diode detector with 2.8mm resolution. Finally, AQA variance and usability were analyzed performing a number of AQA tests over time, which required the use of specially designed fixtures for each array, and the results were compared to film. Concerning sensitivity, the 1000SRS detected the beam profile shifts with a maximum difference of 0.11mm (mean deviation = 0.03mm) compared to the actual robot shift. The Nonius and SRS-Profiler showed differences of up to 0.15mm and 0.69mm with mean deviation of 0.05mm and 0.18mm, respectively. Analyzing the variation of AQA results over time, the 1000SRS showed a comparable standard deviation to film (0.26mm vs. 0.18mm). The SRS-Profiler and the Nonius showed a standard deviation of 0.16mm and 0.24mm, respectively. The 1000SRS seems to provide equivalent accuracy and sensitivity to the gold standard film when performing daily AQA tests. Compared to other detectors in our study the sensitivity as well as the accuracy of the 1000SRS appears to be superior and more user-friendly. Furthermore, no significant modification of the standard AQA procedure is required when introducing 1000SRS for CyberKnife AQA
High resolution ion chamber array delivery quality assurance for robotic radiosurgery: commissioning and validation
AbstractPurposeHigh precision radiosurgery demands comprehensive delivery-quality-assurance techniques. The use of a liquid-filled ion-chamber-array for robotic-radiosurgery delivery-quality-assurance was investigated and validated using several test scenarios and routine patient plans.Methods and materialPreliminary evaluation consisted of beam profile validation and analysis of source–detector-distance and beam-incidence-angle response dependence. The delivery-quality-assurance analysis is performed in four steps: (1) Array-to-plan registration, (2) Evaluation with standard Gamma-Index criteria (local-dose-difference⩽2%, distance-to-agreement⩽2mm, pass-rate⩾90%), (3) Dose profile alignment and dose distribution shift until maximum pass-rate is found, and (4) Final evaluation with 1mm distance-to-agreement criterion. Test scenarios consisted of intended phantom misalignments, dose miscalibrations, and undelivered Monitor Units. Preliminary method validation was performed on 55 clinical plans in five institutions.ResultsThe 1000SRS profile measurements showed sufficient agreement compared with a microDiamond detector for all collimator sizes. The relative response changes can be up to 2.2% per 10cm source–detector-distance change, but remains within 1% for the clinically relevant source–detector-distance range. Planned and measured dose under different beam-incidence-angles showed deviations below 1% for angles between 0° and 80°. Small-intended errors were detected by 1mm distance-to-agreement criterion while 2mm criteria failed to reveal some of these deviations. All analyzed delivery-quality-assurance clinical patient plans were within our tight tolerance criteria.ConclusionWe demonstrated that a high-resolution liquid-filled ion-chamber-array can be suitable for robotic radiosurgery delivery-quality-assurance and that small errors can be detected with tight distance-to-agreement criterion. Further improvement may come from beam specific correction for incidence angle and source–detector-distance response
The dose response functions of ionization chambers in photon dosimetry - Gaussian or non-Gaussian?
This study is concerned with the spatial resolution of air-filled ionization chambers in photon-beam dosimetry, i.e. with their dose response functions. These act as convolution kernels K(x,y), transforming true dose profiles D(x,y) into the measured signal profiles M(x,y). One-dimensional dose response functions have been experimentally determined for nine types of cylindrical ionization chambers both in their lateral and longitudinal directions, as well as across two plane-parallel chambers and for the single chambers of two 2D arrays. All these 1D dose response functions are closely described by Gaussian functions. The associated energy-dependent values of the standard deviations a have been measured for 6 and 15 MV photons with an uncertainty of 0.02 mm. At depths beyond secondary electron fluence build-up, there was no detectable depth dependence of the a values. The general occurrence of Gaussian dose response functions, their extension beyond the geometrical boundaries of the chambers, and the energy dependence of their standard deviations can be understood by considering the underlying system of convolutions, which is the origin of the influences of secondary electron transport. Monte-Carlo simulations of the convolution kernels for a cylindrical, a square, and a flat ionization chamber and their Fourier analysis have been employed to show that the Gaussian convolution kernels are approximations to the true dose response functions, valid in the clinically relevant domain of the spatial frequency. This paper is conceived as the starting point for the deconvolution methods to be described in a further publication
Usability and accuracy of high-resolution detectors for daily quality assurance for robotic radiosurgery
For daily CyberKnife QA a Winston-Lutz-Test (Automated-Quality-Assurance, AQA) is used to determine sub-millimeter deviations in beam delivery accuracy. This test is performed using gafchromic film, an extensive and user-dependent method requiring the use of disposables. We therefore analyzed the usability and accuracy of high-resolution detector arrays. We analyzed a liquid-filled ionization-chamber array (Octavius 1000SRS, PTW, Germany), which has a central resolution of 2.5mm. To test sufficient sensitivity, beam profiles with robot shifts of 0.1mm along the arrays' axes were measured. The detected deviation between the shifted and central profile were compared to the real robot's position. We then compared the results to the SRS-Profiler (SunNuclear, USA) with 4.0mm resolution and to the Nonius (QUART, Germany), a single-line diode detector with 2.8mm resolution. Finally, AQA variance and usability were analyzed performing a number of AQA tests over time, which required the use of specially designed fixtures for each array, and the results were compared to film. Concerning sensitivity, the 1000SRS detected the beam profile shifts with a maximum difference of 0.11mm (mean deviation = 0.03mm) compared to the actual robot shift. The Nonius and SRS-Profiler showed differences of up to 0.15mm and 0.69mm with mean deviation of 0.05mm and 0.18mm, respectively. Analyzing the variation of AQA results over time, the 1000SRS showed a comparable standard deviation to film (0.26mm vs. 0.18mm). The SRS-Profiler and the Nonius showed a standard deviation of 0.16mm and 0.24mm, respectively. The 1000SRS seems to provide equivalent accuracy and sensitivity to the gold standard film when performing daily AQA tests. Compared to other detectors in our study the sensitivity as well as the accuracy of the 1000SRS appears to be superior and more user-friendly. Furthermore, no significant modification of the standard AQA procedure is required when introducing 1000SRS for CyberKnife AQA