18 research outputs found

    Influence of 30 and 60 Min of Hypobaric Hypoxia in Simulated Altitude of 15,000 ft on Human Proteome Profile

    No full text
    The human body reacts to hypobaric hypoxia, e.g., during a stay at high altitude, with several mechanisms of adaption. Even short-time exposition to hypobaric hypoxia leads to complex adaptions. Proteomics facilitates the possibility to detect changes in metabolism due to changes in proteins. The present study aims to identify time-dependent changes in protein expression due to hypobaric hypoxia for 30 and 60 min at a simulated altitude of 15,000 ft. N = 80 male subjects were randomized and assigned into four different groups: 40 subjects to ground control for 30 (GC30) and 60 min (GC60) and 40 subjects to 15,000 ft for 30 (HH30) and 60 min (HH60). Subjects in HH30 and HH60 were exposed to hypobaric hypoxia in a pressure chamber (total pressure: 572 hPa) equivalent to 15,000 ft for 30 vs. 60 min, respectively. Drawn blood was centrifuged and plasma frozen (-80 degrees C) until proteomic analysis. After separation of high abundant proteins, protein expression was analyzed by 2-DIGE and MALDI-TOF. To visualize the connected signaling cascade, a bio-informatical network analysis was performed. The present study was approved by the ethical committee of the University of Cologne, Germany. The study registry number is NCT03823677. In comparing HH30 to GC30, a total of seven protein spots had a doubled expression, and 22 spots had decreased gene expression. In a comparison of HH60 to GC60, a total of 27 protein spots were significantly higher expressed. HH60, as compared to GC30, revealed that a total of 37 spots had doubled expression. Vice versa, 12 spots were detected, which were higher expressed in GC30 vs. HH60. In comparison to GC, HH60 had distinct differences in the number of differential protein spots (noticeably more proteins due to longer exposure to hypoxia). There are indicators that changes in proteins are dependent on the length of hypobaric hypoxia. Some proteins associated with hemostasis were differentially expressed in the 60 min comparison

    Influence of 30 and 60 Min of Hypobaric Hypoxia in Simulated Altitude of 15,000 ft on Human Proteome Profile

    No full text
    The human body reacts to hypobaric hypoxia, e.g., during a stay at high altitude, with several mechanisms of adaption. Even short-time exposition to hypobaric hypoxia leads to complex adaptions. Proteomics facilitates the possibility to detect changes in metabolism due to changes in proteins. The present study aims to identify time-dependent changes in protein expression due to hypobaric hypoxia for 30 and 60 min at a simulated altitude of 15,000 ft. N = 80 male subjects were randomized and assigned into four different groups: 40 subjects to ground control for 30 (GC30) and 60 min (GC60) and 40 subjects to 15,000 ft for 30 (HH30) and 60 min (HH60). Subjects in HH30 and HH60 were exposed to hypobaric hypoxia in a pressure chamber (total pressure: 572 hPa) equivalent to 15,000 ft for 30 vs. 60 min, respectively. Drawn blood was centrifuged and plasma frozen (−80 °C) until proteomic analysis. After separation of high abundant proteins, protein expression was analyzed by 2-DIGE and MALDI-TOF. To visualize the connected signaling cascade, a bio-informatical network analysis was performed. The present study was approved by the ethical committee of the University of Cologne, Germany. The study registry number is NCT03823677. In comparing HH30 to GC30, a total of seven protein spots had a doubled expression, and 22 spots had decreased gene expression. In a comparison of HH60 to GC60, a total of 27 protein spots were significantly higher expressed. HH60, as compared to GC30, revealed that a total of 37 spots had doubled expression. Vice versa, 12 spots were detected, which were higher expressed in GC30 vs. HH60. In comparison to GC, HH60 had distinct differences in the number of differential protein spots (noticeably more proteins due to longer exposure to hypoxia). There are indicators that changes in proteins are dependent on the length of hypobaric hypoxia. Some proteins associated with hemostasis were differentially expressed in the 60 min comparison

    Randomized comparison of two new methods for chest compressions during CPR in microgravity-A manikin study

    Get PDF
    Background: Although there have been no reported cardiac arrests in space to date, the risk of severe medical events occurring during long-duration spaceflights is a major concern. These critical events can endanger both the crew as well as the mission and include cardiac arrest, which would require cardiopulmonary resuscitation (CPR). Thus far, five methods to perform CPR in microgravity have been proposed. However, each method seems insufficient to some extent and not applicable at all locations in a spacecraft. The aim of the present study is to describe and gather data for two new CPR methods in microgravity. Materials and methods: A randomized, controlled trial (RCT) compared two new methods for CPR in a free-floating underwater setting. Paramedics performed chest compressions on a manikin (Ambu Man, Ambu, Germany) using two new methods for a free-floating position in a parallel-group design. The first method (Schmitz-Hinkelbein method) is similar to conventional CPR on earth, with the patient in a supine position lying on the operator\u27s knees for stabilization. The second method (Cologne method) is similar to the first, but chest compressions are conducted with one elbow while the other hand stabilizes the head. The main outcome parameters included the total number of chest compressions (n) during 1 min of CPR (compression rate), the rate of correct chest compressions (%), and no-flow time (s). The study was registered on clinicaltrials.gov (NCT04354883). Results: Fifteen volunteers (age 31.0 ± 8.8 years, height 180.3 ± 7.5 cm, and weight 84.1 ± 13.2 kg) participated in this study. Compared to the Cologne method, the Schmitz-Hinkelbein method showed superiority in compression rates (100.5 ± 14.4 compressions/min), correct compression depth (65 ± 23%), and overall high rates of correct thoracic release after compression (66% high, 20% moderate, and 13% low). The Cologne method showed correct depth rates (28 ± 27%) but was associated with a lower mean compression rate (73.9 ± 25.5/min) and with lower rates of correct thoracic release (20% high, 7% moderate, and 73% low). Conclusions: Both methods are feasible without any equipment and could enable immediate CPR during cardiac arrest in microgravity, even in a single-helper scenario. The Schmitz-Hinkelbein method appears superior and could allow the delivery of high-quality CPR immediately after cardiac arrest with sufficient quality

    Time to ventilation and success rate of airway devices in microgravity: A randomized crossover manikin-trial using an underwater setting

    No full text
    BACKGROUND: Medical support for space exploration missions must prepare for severe medical events in conditions of microgravity. A key component to managing these events is techniques of airway management. The aim of the present trial is to compare airway management devices in simulated microgravity. METHODS: In this randomized cross-over trial (RCT), four different devices were compared under simulated microgravity conditions utilizing a neutrally buoyant free-floating underwater manikin and poolside in normal gravity (control group). The primary endpoint was the successful placement of the airway device. The secondary endpoints were the number of attempts and the duration of each attempt. RESULTS: A total of 20 participants performed placement of each device in both gravity conditions in an Airway mannequin. The fastest time to initial ventilation in simulated microgravity was possible with the laryngeal tube (18.9 ± 8 seconds) followed by laryngeal mask (20.1 ± 9 seconds). The I-gel® supraglottic airway device required substantially more time for successful insertion in simulated microgravity (35.4 ± 25 seconds) as did endotracheal tube intubation by direct laryngoscopy (70.4 ± 35 seconds). Simulated microgravity conditions prolonged time to initial ventilation by 3.3 seconds (LM), 3.9 seconds (LT), 19.9 seconds (I-gel) and 43.1 seconds (endotracheal intubation, ETI) when compared to poolside attempts in normogravity. CONCLUSION: In simulated microgravity conditions, use of the laryngeal tube or laryngeal mask provided the quickest time to initial ventilation, without deliberate tethering of the mannequin and rescuer to a fixed surface. Endotracheal intubation required significantly longer procedure times and, thus, was considered insufficient for clinical use in microgravity

    Using supraglottic airways by paramedics for airway management in analogue microgravity increases speed and success of ventilation

    No full text
    In the next few years, the number of long-term space missions will significantly increase. Providing safe concepts for emergencies including airway management will be a highly challenging task. The aim of the present trial is to compare different airway management devices in simulated microgravity using a free-floating underwater scenario. Five different devices for airway management [laryngeal mask (LM), laryngeal tube (LT), I-GEL, direct laryngoscopy (DL), and video laryngoscopy (VL)] were compared by n = 20 paramedics holding a diving certificate in a randomized cross-over setting both under free-floating conditions in a submerged setting (pool, microgravity) and on ground (normogravity). The primary endpoint was the successful placement of the airway device. The secondary endpoints were the number of attempts and the time to ventilation. A total of 20 paramedics (3 female, 17 male) participated in this study. Success rate was highest for LM and LT and was 100% both during simulated microgravity and normogravity followed by the I-GEL (90% during microgravity and 95% during normogravity). However, the success rate was less for both DL (60% vs. 95%) and VL (20% vs. 60%). Fastest ventilation was performed with the LT both in normogravity (13.7 ± 5.3 s; n = 20) and microgravity (19.5 ± 6.1 s; n = 20). For the comparison of normogravity and microgravity, time to ventilation was shorter for all devices on the ground (normogravity) as compared underwater (microgravity). In the present study, airway management with supraglottic airways and laryngoscopy was shown to be feasible. Concerning the success rate and time to ventilation, the optimum were supraglottic airways (LT, LM, I-GEL) as their placement was faster and associated with a higher success rate. For future space missions, the use of supraglottic airways for airway management seems to be more promising as compared to tracheal intubation by DL or VL

    Using supraglottic airways by paramedics for airway management in analogue microgravity increases speed and success of ventilation

    No full text
    In the next few years, the number of long-term space missions will significantly increase. Providing safe concepts for emergencies including airway management will be a highly challenging task. The aim of the present trial is to compare different airway management devices in simulated microgravity using a free-floating underwater scenario. Five different devices for airway management [laryngeal mask (LM), laryngeal tube (LT), I-GEL, direct laryngoscopy (DL), and video laryngoscopy (VL)] were compared by n=20 paramedics holding a diving certificate in a randomized cross-over setting both under free-floating conditions in a submerged setting (pool, microgravity) and on ground (normogravity). The primary endpoint was the successful placement of the airway device. The secondary endpoints were the number of attempts and the time to ventilation. A total of 20 paramedics (3 female, 17 male) participated in this study. Success rate was highest for LM and LT and was 100% both during simulated microgravity and normogravity followed by the I-GEL (90% during microgravity and 95% during normogravity). However, the success rate was less for both DL (60% vs. 95%) and VL (20% vs. 60%). Fastest ventilation was performed with the LT both in normogravity (13.7 +/- 5.3 s; n=20) and microgravity (19.5 +/- 6.1 s; n=20). For the comparison of normogravity and microgravity, time to ventilation was shorter for all devices on the ground (normogravity) as compared underwater (microgravity). In the present study, airway management with supraglottic airways and laryngoscopy was shown to be feasible. Concerning the success rate and time to ventilation, the optimum were supraglottic airways (LT, LM, I-GEL) as their placement was faster and associated with a higher success rate. For future space missions, the use of supraglottic airways for airway management seems to be more promising as compared to tracheal intubation by DL or VL
    corecore