    Silicone oil: Different physical proprieties and clinical applications

    Get PDF
    Silicone oils are important tools in vitreoretinal surgery because they have the ability to displace aqueous humor from the retinal surface, maintaining the adhesion between retina and retinal pigment epithelium. To understand this capability, it is important to know the silicone oil characteristics. Herein, we report first on the main chemical-physical proprieties and then we review the clinical applications of the current silicone oil which is lighter than water with particular reference to their indications with small gauge vitrectomy. Finally, we describe the surgical techniques to inject and remove this type of silicone oil. In the summary of this paper, we explain why silicone oils are today increasingly used and why their introduction has improved the prognosis of several retinal diseases. In fact, having different types of silicone oils allows us to choose the appropriate endotamponade for every single case

    Impact of the COVID-19 pandemic on ophthalmologic outpatient care: experience from an Italian Tertiary Medical Center

    Get PDF
    Purpose: To evaluate the impact the COVID-19-related national lockdown has had on Ophthalmologic Outpatient Care in an Italian Tertiary Medical Centre. Methods: We reviewed all the performances that were carried out as outpatient services at our department between 1 January 2020 and 30 November 2020. We compared data among four different periods: from 1 January 2020 to 17 March 2020 ("Pre-Lockdown"); from 18 March 2020 to 17 May 2020 (Lockdown); from 18 May 2020 to 2 November 2020 (Post-Lockdown) and from 3 November 2020 to 30 November 2020 (Regional Lockdown). Results: The overall number of performed routine outpatient visits per day (ROVs) was 11,871 (Mean \ub1 SD = 35.76 \ub1 17.81), whereas booked appointments (BAs) were 21272 (Mean \ub1 SD = 63.86 \ub1 9.27), meaning a decline in the number of ROVs by 44.01%. (Mean \ub1 SD = 28.10 \ub1 12.11, p<.001). Post-Lockdown and Regional Lockdown clinical activities, dropped respectively by 31 and 25.14% (38.87 \ub1 3.88 vs. 56.34 \ub1 11.06, p<.001 and 6.04 \ub1 4.51 vs. 56.34 \ub1 11.06 p<.001). The number of BAs per day decreased during the pandemic, going from a mean of 77.81 \ub1 2.57 booked appointments per day before the lockdown, to a mean of 53.14 \ub1 4.94, 61.80 \ub1 4.62 and 72.07 \ub1 1.09 appointments per day respectively during the lockdown, the post-lockdown and the regional lockdown periods. Conclusions: During the various lockdown periods, at our institution the volume of outpatient ophthalmological visits drastically dropped. This testifies the dramatic impact the COVID-19 pandemic has had on the supply of ophthalmic care

    Swept-source OCT reduces the risk of axial length measurement errors in eyes with cataract and epiretinal membranes

    Get PDF
    Aims: To compare the biometric data from partial coherence interferometry (PCI) and swept-source OCT (SS-OCT) in patients with age-related cataract and epiretinal membrane (ERM): ERM, ERM with foveoschisis and macular pseudohole. Methods: 49 eyes of 49 subjects including 36 ERM, 9 ERM foveoschisis and 4 macular pseudohole were analysed to evaluate the axial length (AL) measurements and the presence of AL measurement errors, defined basing on the shape of the biometric output graphs and on the concordance of AL values between instruments. Eyes with ERM were divided in four stages according to OCT features (i.e. presence/absence of the foveal pit, presence of ectopic inner foveal layers, disrupted retinal layers). Results: The devices provided similar mean AL measurements in all subgroups, with differences <0.1 mm in 41/49 cases (83.6%). AL measurement errors were observed in ERM stages 3 and 4, characterized by ectopic inner foveal layers, and were significantly more frequent with the PCI (8/17, 47%) as compared with the SS-OCT device (2/17, 12%), p = 0.02. The refractive prediction error in cases with AL measurement errors was significantly greater using the PCI compared to the SS-OCT device (p<0.05). Conclusion: Both devices provide reliable biometric data in the majority of patients and can be used in the preoperative assessment of patients with age-related cataract and ERM. In eyes with ectopic inner foveal layers, attention should be paid as AL measurement and refractive prediction errors may occur, more frequently with the PCI device

    Visual BOLD Response in Late Blind Subjects with Argus II Retinal Prosthesis

    Get PDF
    Retinal prosthesis technologies require that the visual system downstream of the retinal circuitry be capable of transmitting and elaborating visual signals. We studied the capability of plastic remodeling in late blind subjects implanted with the Argus II Retinal Prosthesis with psychophysics and functional MRI (fMRI). After surgery, six out of seven retinitis pigmentosa (RP) blind subjects were able to detect high-contrast stimuli using the prosthetic implant. However, direction discrimination to contrast modulated stimuli remained at chance level in all of them. No subject showed any improvement of contrast sensitivity in either eye when not using the Argus II. Before the implant, the Blood Oxygenation Level Dependent (BOLD) activity in V1 and the lateral geniculate nucleus (LGN) was very weak or absent. Surprisingly, after prolonged use of Argus II, BOLD responses to visual input were enhanced. This is, to our knowledge, the first study tracking the neural changes of visual areas in patients after retinal implant, revealing a capacity to respond to restored visual input even after years of deprivation

    Spotlight on MicroPulse laser trabeculoplasty in open-angle glaucoma: What's on? A eeview of the literature

    Get PDF
    Glaucoma is the most common cause of permanent blindness in the world, caused by a progressive optic neuropathy. Patients with glaucoma are often treated with topical medicines therapy in order to reduce intra-ocular pressure (IOP). On the other hand, laser therapies, with the introduction of Argon Laser Trabeculoplasty (ALT) and successively with Selective Laser Trabeculoplasty (SLT), were reported to be effective in IOP control, with low adverse effect rates. In recent years, the micropulse laser, a subthreshold laser technology, was introduced with the goal of reducing side effects while maintaining the effectiveness of the laser treatments. Several studies focused on Micropulse Diode Laser Trabeculoplasty (MDLT) in open-angle glaucoma, to evaluate its effectiveness and possible side effects. Promising results were reported, but irradiation circumstances have not been standardized yet and its role as a substitute for previous laser techniques has yet to be defined. As a result, the goal of this review was to analyze the physical principles at the basis of MDLT and to frame it in the open-angle glaucoma management setting, highlighting the advantages and shortfalls of this technique

    Optical Coherence Tomography Angiography for the Evaluation of Retinal and Choroidal Vasculature in Retinitis Pigmentosa: A Monocentric Experience

    Get PDF
    Purpose: We investigated the chorioretinal microvascular changes in patients with retinitis pigmentosa (RP) by optical coherence tomography angiography (OCTA). Methods: Twenty-six patients (52 eyes) affected by RP were compared with 19 healthy controls (38 eyes). OCTA 3 mm × 3 mm macular scans were performed in all subjects. We evaluated the vessel density (VD) of the superficial capillary plexus (VD SCP), deep capillary plexus (VD DCP), choriocapillaris (VD CC), and choroid (VD choroid). We also evaluated the foveal avascular zone (FAZ) area, and the correlation between clinical and OCTA parameters. We also measured central retinal thickness (CRT) and subfoveal choroidal thickness (CT). Results: RP patients compared to healthy controls showed significantly lower VD SCP values (27.56% ± 15.37 vs. 49.39% ± 1.55; p-value < 0.0001), lower VD DCP values (38.43% ± 15.23 vs. 3.34% ± 0.26; p-value < 0.0001), lower VD CC values (46.02% ± 1.293 vs. 50.63% ± 0.4274; p-value = 0.0040), and lower VD choroid values (38.48% ± 15.23 vs. 3.34% ± 0.26; p-value < 0.0001). Even the FAZ area was significantly lower in RP patients (0.45 mm(2) ± 0.35 vs. 0.26 mm(2) ± 0.13; p-value < 0.0001). The FAZ area was larger with increasing age, both in control (r = 0.42; p = 0.012) and RP group (r = 0.46; p-value = 0.009). In RP patients, there was a statistically significant correlation between best-corrected visual acuity and VD SCP (r = 0.24, p-value = 0.04) and VD DCP (r = 0.52; p-value = 0.0004) and between subfoveal choroidal thickness and VD SCP (r = 0.43, p-value < 0.001) and VD DCP (r = 0.35, p-value < 0.001). Conclusions: In our study, OCTA reported relevant vascular alterations in RP patients in comparison with the healthy controls, in agreement with the published literature. These abnormalities were associated with choroidal atrophy and related to visual acuity loss. OCTA provided clinically significant information and may represent a reliable tool for the management of RP patients

    Overview on defocus incorporated multiple segments lenses: a novel perspective in myopia progression management

    Get PDF
    Myopia is becoming more common across the world, affecting approximately two billion people and rising. Different kinds of therapies (optical, pharmaceutical, environmental, or behavioral) have been proposed to decrease myopia progression, but with variable results and a lack of standardization. The evidence that targeted myopic defocus inhibits eye length growth has paved the way for several contact and spectacle lense designs to induce a peripheral defocus, thus slowing myopia progression, but the perfect configuration has yet to be defined. One of the newest and more promising approaches in this field is the use of Defocus Incorporated Multiple Segments (DIMS) lenses. These lenses are built from the assumption that targeted myopic defocus, produced by 396 mid-peripheral lenslets with positive power, inhibits eye length growth. Recent studies have highlighted the effectiveness of these lenses compared to children who had worn single vision spectacle lenses, in terms of myopia control and tolerability. Despite the evidence that these lenses can help slow down the progression of myopia, the occasional mid-peripheral aberrations they can induce, as well as the overall eye strain that comes with wearing them, should not be overlooked. The aim of this review is to give attention to the advantages and the shortfalls of this new approach and to evaluate its effectiveness in clinical practice

    PreserFlo® MicroShunt: an overview of this minimally invasive device for open-angle glaucoma

    Get PDF
    For moderate-to-severe glaucoma, trabeculectomy remains the “gold standard” intraocular pressure (IOP)-lowering treatment; nonetheless, this method requires extensive post-operative maintenance. Microinvasive glaucoma surgery (MIGS) treatments are designed to lessen intra- and post-operative care burden while offering an acceptable IOP decrease for individuals with mild to moderate glaucoma. The PreserFlo® MicroShunt (previously InnFocus MicroShunt) is an 8.5 mm glaucoma drainage device manufactured from poly(styrene-block-isobutylene-block-styrene) (SIBS), an extremely biocompatible and bioinert material. The lumen is narrow enough to prevent hypotony, but big enough to avoid being obstructed by sloughed cells or pigment. The device is implanted ab externo, as a stand-alone procedure or in conjunction with cataract surgery, with intraoperative mitomycin C, and a bleb is produced under the conjunctiva and Tenon’s capsule. The MicroShunt was CE-marked in 2012 and designed for primary open-angle glaucoma, the IOP of which remains uncontrolled after maximally tolerated topical treatment. Several clinical trials evaluating the MicroShunt’s long-term safety and effectiveness have been conducted, highlighting the effectiveness of the device over time, along with a tolerable safety profile. The present review aims to gather evidence of PreserFlo’s effectiveness and safety results almost 10 years after its introduction, and furthermore, to compare it with other MIGS and with the gold-standard trabeculectomy for glaucoma management
    • …