6 research outputs found

    Laboratory quick near edge x-ray absorption fine structure spectroscopy in the soft x-ray range with 100 Hz frame rate using CMOS technology

    Get PDF
    In laboratory based x-ray absorption fine structure (XAFS) spectroscopy, the slow readout speed of conventional CCD cameras can prolong the measuring times by multiple orders of magnitude. Using pulsed sources, e.g., laser-based x-ray sources, the pulse repetition rate often exceeds the frame rate of the CCD camera. We report the use of a scientific CMOS (sCMOS) camera for XAFS spectroscopy with a laser-produced plasma source facilitating measurements at 100 Hz. With this technological improvement, a new class of experiments becomes possible, starting from the time consuming analysis of samples with small absorption to pump-probe investigations. Furthermore, laboratory quick soft x-ray absorption fine structure (QXAFS) measurements with 10 ms time resolution are rendered feasible. We present the characterization of the sCMOS camera concerning noise characteristics and a comparison to conventional CCD camera performance. The feasibility of time resolved QXAFS measurements is shown by analyzing the statistical uncertainty of single shot spectra. Finally, XAFS spectroscopy on a complex sandwich structure with minute amounts of NiO exemplifies the additional merits of fast detectors.DFG, 313838950, Neuartiges Laborspektrometer für Pump-Probe NEXAFS-Untersuchungen an Biomolekülen in wässriger LösungEC/H2020/654148/EU/The Integrated Initiative of European Laser Research Infrastructures/LASERLAB-EUROP

    The H1 detector at HERA

    No full text

    The Tracking, calorimeter and muon detectors of the H1 experiment at HERA

    No full text
    Technical aspects of the three major components of the H1 detector at the electron-proton storage ring HERA are described. This paper covers the detector status up to the end of 1994 when a major upgrading of some of its elements was undertaken. A description of the other elements of the detector and some performance figures from luminosity runs at HERA during 1993 and 1994 are given in a paper previously published in this journal.0400 auteursSCOPUS: ar.jinfo:eu-repo/semantics/publishe

    The tracking calorimeter and muon detectors of the H1 experiment at Hera

    No full text

    The H1 detector at HERA

    No full text

    The H1 detector at HERA

    No full text
    General aspects of the H1 detector at the electron-proton storage ring HERA as well as technical descriptions of the magnet, luminosity system, trigger, slow-control, data acquisition and off-line data handling are given. The three major components of the detector, the tracking, calorimeter and muon detectors, will be described in a forthcoming article. The present paper describes the detector that was used from 1992 to the end of 1994. After this a major upgrade of some components was undertaken. Some performance figures from luminosity runs at HERA during 1993 and 1994 are given.0SCOPUS: ar.jinfo:eu-repo/semantics/publishe
    corecore