88 research outputs found

    Microwave soft x-ray microscopy for nanoscale magnetization dynamics in the 5-10 GHz frequency range

    Full text link
    We present a scanning transmission x-ray microscopy setup combined with a novel microwave synchronization scheme in order to study high frequency magnetization dynamics at synchrotron light sources. The sensitivity necessary to detect small changes of the magnetization on short time scales and nanometer spatial dimensions is achieved by combination of the developed excitation mechanism with a single photon counting electronics that is locked to the synchrotron operation frequency. The required mechanical stability is achieved by a compact design of the microscope. Our instrument is capable of creating direct images of dynamical phenomena in the 5-10 GHz range, with 35 nm resolution. When used together with circularly polarized x-rays, the above capabilities can be combined to study magnetic phenomena at microwave frequencies, such as ferromagnetic resonance (FMR) and spin waves. We demonstrate the capabilities of our technique by presenting phase resolved images of a 6 GHz nanoscale spin wave generated by a spin torque oscillator, as well as the uniform ferromagnetic precession with ~0.1 deg amplitude at 9 GHz in a micrometer-sized cobalt strip.Comment: 9 pages, 7 figure

    Pharmacokinetic properties of remimazolam in subjects with hepatic or renal impairment

    Get PDF
    BACKGROUND: Remimazolam is a new benzodiazepine for procedural sedation and general anaesthesia. The aim of this study was to characterise its pharmacokinetic properties and safety in renally and hepatically impaired subjects. METHODS: Two separate trials were conducted in patients with hepatic (n=11) or renal impairment (n=11) compared with matched healthy subjects (n=9 and n=12, respectively). The hepatic impairment trial was an open-label adaptive 'Reduced Design' trial, using a single bolus of remimazolam 0.1 mg kg-1 i.v., whereas the renal impairment trial was an open-label trial of a single bolus dose of remimazolam 1.5 mg i.v. Remimazolam plasma concentrations over time were analysed by population pharmacokinetic modelling. RESULTS: Remimazolam pharmacokinetic properties were adequately described by a three-compartment, recirculatory model. Exposure in subjects with severe hepatic impairment was 38.1% higher (i.e. clearance was 38.1% lower) compared with healthy volunteers. This increase caused a slightly delayed recovery (8.0 min for healthy, 12.1 min for moderate, and 16.7 min for severe hepatic impairment). With renal impairment, plasma clearance was comparable with that measured in healthy subjects. Simulations of Cmax after a bolus dose of 10 mg showed no relevant impact of hepatic or renal impairment. The overall incidence of adverse events was low, and all adverse events were mild. CONCLUSIONS: As Cmax after a remimazolam bolus i.v. was not affected by hepatic or renal impairment, no dose adjustments are required. No unexpected adverse events related to remimazolam were seen in subjects with renal or hepatic impairment. CLINICAL TRIAL REGISTRATION: Hepatic impairment trial: ClinicalTrials.gov, NCT01790607 (https://clinicaltrials.gov/ct2/show/NCT01790607). Renal impairment trial: EudraCT Number: 2014-004575-23

    In situ characterization of the deposition of anatase TiO2 on rutile TiO2(110)

    Get PDF
    Growing additional TiO2 thin films on TiO2 substrates in ultrahigh vacuum (UHV)-compatible chambers have many applications for sample preparation, such as smoothing surface morphologies, templating, and covering impurities. However, there has been little study into how to control the morphology of TiO2 films deposited onto TiO2 substrates, especially using atomic layer deposition (ALD) precursors. Here, the authors show the growth of a TiO2 film on a rutile TiO2(110) surface using titanium tetraisopropoxide (TTIP) and water as the precursors at pressures well below those used in common ALD reactors. X-ray absorption spectroscopy suggests that the relatively low sample temperature (175 °C) results in an anatase film despite the rutile template of the substrate. Using ambient pressure x-ray photoelectron spectroscopy, the adsorption of TTIP was found to be self-limiting, even at room temperature. No molecular water was found to adsorb on the surface. The deposited thickness suggests that an alternate chemical vapor deposition growth mechanism may be dominating the growth process. This study highlights the possibility that metal oxide film deposition from molecular precursors is an option for sample preparations in common UHV-compatible chambers
    • …
    corecore