23 research outputs found

    High Responsivity in Molecular Beam Epitaxy (MBE) grown \b{eta}-Ga2O3 Metal Semiconductor Metal (MSM) Solar Blind Deep-UV Photodetector

    Full text link
    In this report, we demonstrate high spectral responsivity (SR) in MBE grown epitaxial \b{eta}-Ga2O3-based solar blind MSM photodetectors (PD). (-2 0 1)-oriented \b{eta}-Ga2O3 thin film was grown by plasma-assisted MBE on c-plane sapphire substrates. MSM devices fabricated with Ni/Au contacts in an interdigitated geometry were found to exhibit peak SR > 1.5 A/W at 236-240 nm at a bias of 4 V with a UV to visible rejection ratio > 105. The devices exhibited very low dark current < 10 nA at 20 V and showed no persistent photoconductivity (PPC) as evident from the sharp transients with a photo-to-dark current ratio > 103. These results represent the state-of-art performance for MBE-grown \b{eta}-Ga2O3 MSM solar blind detector

    Immediate, intermediate and long term clinical outcomes of percutaneous transvenous mitral commissurotomy

    No full text
    Percutaneous transvenous mitral commissurotomy (PTMC) is one of the nonsurgical commissurotomy in patients with hemodynamically significant mitral stenosis. The aim of the present study is to assess the immediate, intermediate and long term outcomes of PTMC in relation to initial mitral valve score and to assess its impact on mitral valve area (MVA), clinical and hemodynamic parameters. It is a retrospective study on a total of 303 patients who underwent successful PTMC between 1994 and 2001, were called back and their preprocedural, immediate post and follow-up (4, 7 and 10 year.) data were analyzed. Echo was performed in patients before and after PTMC. The patients were divided into two groups, group-I with Wilkins score of ≤ 8 and group-II with Wilkins score between 8 and 12. PTMC patients who have completed 4, 7 and 10 years of follow up revealed the mitral valve area, mean transmitral gradient and pulmonary artery pressures to be significantly different in both group-I and group-II. At all follow-up periods group-II showed higher restenosis than group-I, but its distribution between the groups was not statistically significant (χ2 = 0.029, p = 0.986). Furthermore, losses of the MVA during different periods of follow-up revealed a gradual increase in attrition. MV score, Mitral valve area, mitral gradient and pulmonary artery pressures appeared to influence the outcome of PTMC. A clear-cut prospective assessment of individual components of the mitral valve apparatus using 3-D echocardiographic images may provide a more precise prediction of the PTMC outcome based on its morphological abnormalities

    A 0.4% PAE 194-GHz Signal Source With 1.5-mW Output Power in 65-nm Bulk CMOS Technology

    No full text

    Decoupling Structures for Millimeter Wave Integrated Circuits in Digital CMOS Processes

    No full text

    Bayesian view of single-qubit clocks, and an energy versus accuracy tradeoff

    No full text
    We bring a Bayesian approach to the analysis of clocks. Using exponential distributions as priors for clocks, we analyze how well one can keep time with a single qubit freely precessing under a magnetic field. We find that, at least with a single qubit, quantum mechanics does not allow exact timekeeping, in contrast to classical mechanics, which does. We find the design of the single-qubit clock that leads to maximum accuracy. Further, we find an energy versus accuracy tradeoff-the energy cost is at least kBT times the improvement in accuracy as measured by the entropy reduction in going from the prior distribution to the posterior distribution. We propose a physical realization of the single-qubit clock using charge transport across a capacitively coupled quantum dot
    corecore