477 research outputs found
Integrating Optical Wireless Communication Into an Optical Bifocal Metrology for Aerospace
Recently an innovative bifocal optical metrology method was proposed for space applications (e.g., rendez-vous and docking), based on unmodulated white LEDs. Here we design, realize, and test a solution that upgrades the metrology to include a digital communication feature, with no modification of the optical elements of the original system: indeed, the scheme exploits the same optical sources that are needed for metrology, which are now also working as optical antennas as their intensity is now modulated. At the receiver side, the conventional camera is now sided by a common photodiode. The system provides unidirectional data communication at 10 kbit/s speed. It is designed to support manoeuvres up to 400 m distance. The lab tests confirm the effectiveness of the proposed solutions, showing correct data transfer without any noticeable degradation of the metrology system
PERCORSI RETURN E TRAVERSAL IN UN SISTEMA DI PICKING
L'analisi dei percorsi return e traversal in un seistema di picking di una società di distribuzione utensili. Si evidenziano le aree di applicazione delle due differenti politiche nel caso di prelievo da scaffali a ripiani o da palle
Parameterization Models for Traceable Characterization of Planar CPW SOL Calibration Standards
International audienceMethods for traceable characterization and uncertainty evaluation of planar 1-port CPW short-open-load (SOL) devices are developed. The agreement of modelling and verification measurement results greatly supports the application of the proposed parameterization models and used FEM-based EM modelling of CPW structures for traceable characterization of planar CPW-based SOL devices in the frequency range between a few kHz up to 50 GHz
ACE Gene I/D Polymorphism and Acute Pulmonary Embolism in COVID19 Pneumonia: A Potential Predisposing Role
Most recent studies have stressed a high risk of thromboembolism in patients with SARS-CoV-2 infection, particularly in those with severe COVID-19 pneumonia. Counterbalance between angiotensin-converting-enzyme (ACE) and ACE2 activities in COVID-19 disease may be crucially involved in the thrombo-inflammatory process. Currently, no study has investigated ACE I/D polymorphism involvement in COVID-19 disease complicated by pulmonary embolism, hence the aim of the present pilot study. This is a retrospective, single-center observational case-control study, conducted at the Sub-Intensive Care Unit of A.O.R.N. Ospedali dei Colli, Cotugno Hospital, Naples (Italy). We included 68 subjects with severe/critical COVID-19 pneumonia. COVID-19 patients were divided according to occurrence of PE (PE+, n = 25) or absence of thromboembolic complications (PE−, n = 43). Assessment of ACE I/D polymorphisms showed a statistically significant difference between PE+ and PE− patients (p = 0.029). Particularly, prevalence of D/D homozygous polymorphism was significantly higher in PE+ COVID-19 patients than in PE− (72 vs. 46.5%; p = 0.048), while heterozygote I/D polymorphism was significantly lower expressed in PE+ patients than in PE− (16 vs. 48.8%; p = 0.009). Computed tomographic pulmonary angiography showed predominantly mono/bilateral sub-segmental embolisms. In conclusion, our findings let us hypothesize a genetic susceptibility to thromboembolism in COVID-19 disease. ACE D/D polymorphism might represent a genetic risk factor, although studies on larger populations are needed
Graphene Plasmonic Fractal Metamaterials for Broadband Photodetectors
Metamaterials have recently established a new paradigm for enhanced light absorption in state-of-the-art photodetectors. Here, we demonstrate broadband, highly efficient, polarization-insensitive, and gate-tunable photodetection at room temperature in a novel metadevice based on gold/graphene Sierpinski carpet plasmonic fractals. We observed an unprecedented internal quantum efficiency up to 100% from the near-infrared to the visible range with an upper bound of optical detectivity of 1011 Jones and a gain up to 106, which is a fingerprint of multiple hot carriers photogenerated in graphene. Also, we show a 100-fold enhanced photodetection due to highly focused (up to a record factor of |E/E0| ≈ 20 for graphene) electromagnetic fields induced by electrically tunable multimodal plasmons, spatially localized in self-similar fashion on the metasurface. Our findings give direct insight into the physical processes governing graphene plasmonic fractal metamaterials. The proposed structure represents a promising route for the realization of a broadband, compact, and active platform for future optoelectronic devices including multiband bio/chemical and light sensors
VST - VLT Survey Telescope Integration Status
The VLT Survey Telescope (VST) is a 2.6m aperture, wide field, UV to I
facility, to be installed at the European Southern Observatory (ESO) on the
Cerro Paranal Chile. VST was primarily intended to complement the observing
capabilities of VLT with wide-angle imaging for detecting and
pre-characterising sources for further observations with the VLT.Comment: 2 pages, 2 figures, conferenc
Recurrence quantification analysis of heart rate variability to detect both ventilatory thresholds
Aims of this study were: To verify if Recurrence Quantification Analysis (RQA) of Heart Rate Variability (HRV) time series could determine both ventilatory thresholds in individuals with different fitness levels, and to assess the validity of RQA method compared to gasexchange method (GE). The two thresholds were estimated in thirty young individuals during incremental exercise on cycle-ergometer: Heart rate (HR), Oxygen consumption (VO2) and Workload were measured by the two methods (RQA and GE). Repeated measures ANOVA was used to assess main effects of methods and methods-by-groups interaction effects for HR, VO2 and Workload at aerobic (AerT) and anaerobic (AnT) thresholds. Validity of RQA at both thresholds was assessed for HR, VO2 and Workload by Ordinary Least Products (OLP) regression, Typical Percentage Error (TE), Intraclass Correlation Coefficients (ICC) and the Bland Altman plots. No methods-by-groups interaction effects were detected for HR, VO2 and Workload at AerT and AnT. The OLP analysis showed that at both thresholds RQA and GE methods had very strong correlations (r >0.8) in all variables (HR, VO2 and Workload). Slope and intercept values always included the 1 and the 0, respectively. At AerT the TE ranged from 4.02% (5.48 bpm) to 10.47% (8.53 Watts) (HR and Workload, respectively) and in all variables ICC values were excellent (≥0.85). At AnT the TE ranged from 2.53% (3.98 bpm) to 6.64% (7.81 Watts) (HR and Workload, respectively) and in all variables ICC values were excellent (≥0.90). Therefore, RQA of HRV time series is a new valid approach to determine both ventilatory thresholds in individuals with different physical fitness levels, it can be used when gas analysis is not possible or not convenient
- …