447 research outputs found

    Integrating Optical Wireless Communication Into an Optical Bifocal Metrology for Aerospace

    Get PDF
    Recently an innovative bifocal optical metrology method was proposed for space applications (e.g., rendez-vous and docking), based on unmodulated white LEDs. Here we design, realize, and test a solution that upgrades the metrology to include a digital communication feature, with no modification of the optical elements of the original system: indeed, the scheme exploits the same optical sources that are needed for metrology, which are now also working as optical antennas as their intensity is now modulated. At the receiver side, the conventional camera is now sided by a common photodiode. The system provides unidirectional data communication at 10 kbit/s speed. It is designed to support manoeuvres up to 400 m distance. The lab tests confirm the effectiveness of the proposed solutions, showing correct data transfer without any noticeable degradation of the metrology system

    PERCORSI RETURN E TRAVERSAL IN UN SISTEMA DI PICKING

    Get PDF
    L'analisi dei percorsi return e traversal in un seistema di picking di una società di distribuzione utensili. Si evidenziano le aree di applicazione delle due differenti politiche nel caso di prelievo da scaffali a ripiani o da palle

    Parameterization Models for Traceable Characterization of Planar CPW SOL Calibration Standards

    Get PDF
    International audienceMethods for traceable characterization and uncertainty evaluation of planar 1-port CPW short-open-load (SOL) devices are developed. The agreement of modelling and verification measurement results greatly supports the application of the proposed parameterization models and used FEM-based EM modelling of CPW structures for traceable characterization of planar CPW-based SOL devices in the frequency range between a few kHz up to 50 GHz

    ACE Gene I/D Polymorphism and Acute Pulmonary Embolism in COVID19 Pneumonia: A Potential Predisposing Role

    Get PDF
    Most recent studies have stressed a high risk of thromboembolism in patients with SARS-CoV-2 infection, particularly in those with severe COVID-19 pneumonia. Counterbalance between angiotensin-converting-enzyme (ACE) and ACE2 activities in COVID-19 disease may be crucially involved in the thrombo-inflammatory process. Currently, no study has investigated ACE I/D polymorphism involvement in COVID-19 disease complicated by pulmonary embolism, hence the aim of the present pilot study. This is a retrospective, single-center observational case-control study, conducted at the Sub-Intensive Care Unit of A.O.R.N. Ospedali dei Colli, Cotugno Hospital, Naples (Italy). We included 68 subjects with severe/critical COVID-19 pneumonia. COVID-19 patients were divided according to occurrence of PE (PE+, n = 25) or absence of thromboembolic complications (PE−, n = 43). Assessment of ACE I/D polymorphisms showed a statistically significant difference between PE+ and PE− patients (p = 0.029). Particularly, prevalence of D/D homozygous polymorphism was significantly higher in PE+ COVID-19 patients than in PE− (72 vs. 46.5%; p = 0.048), while heterozygote I/D polymorphism was significantly lower expressed in PE+ patients than in PE− (16 vs. 48.8%; p = 0.009). Computed tomographic pulmonary angiography showed predominantly mono/bilateral sub-segmental embolisms. In conclusion, our findings let us hypothesize a genetic susceptibility to thromboembolism in COVID-19 disease. ACE D/D polymorphism might represent a genetic risk factor, although studies on larger populations are needed

    Graphene Plasmonic Fractal Metamaterials for Broadband Photodetectors

    Get PDF
    Metamaterials have recently established a new paradigm for enhanced light absorption in state-of-the-art photodetectors. Here, we demonstrate broadband, highly efficient, polarization-insensitive, and gate-tunable photodetection at room temperature in a novel metadevice based on gold/graphene Sierpinski carpet plasmonic fractals. We observed an unprecedented internal quantum efficiency up to 100% from the near-infrared to the visible range with an upper bound of optical detectivity of 1011 Jones and a gain up to 106, which is a fingerprint of multiple hot carriers photogenerated in graphene. Also, we show a 100-fold enhanced photodetection due to highly focused (up to a record factor of |E/E0| ≈ 20 for graphene) electromagnetic fields induced by electrically tunable multimodal plasmons, spatially localized in self-similar fashion on the metasurface. Our findings give direct insight into the physical processes governing graphene plasmonic fractal metamaterials. The proposed structure represents a promising route for the realization of a broadband, compact, and active platform for future optoelectronic devices including multiband bio/chemical and light sensors

    VST - VLT Survey Telescope Integration Status

    Full text link
    The VLT Survey Telescope (VST) is a 2.6m aperture, wide field, UV to I facility, to be installed at the European Southern Observatory (ESO) on the Cerro Paranal Chile. VST was primarily intended to complement the observing capabilities of VLT with wide-angle imaging for detecting and pre-characterising sources for further observations with the VLT.Comment: 2 pages, 2 figures, conferenc

    Recurrence quantification analysis of heart rate variability to detect both ventilatory thresholds

    Get PDF
    Aims of this study were: To verify if Recurrence Quantification Analysis (RQA) of Heart Rate Variability (HRV) time series could determine both ventilatory thresholds in individuals with different fitness levels, and to assess the validity of RQA method compared to gasexchange method (GE). The two thresholds were estimated in thirty young individuals during incremental exercise on cycle-ergometer: Heart rate (HR), Oxygen consumption (VO2) and Workload were measured by the two methods (RQA and GE). Repeated measures ANOVA was used to assess main effects of methods and methods-by-groups interaction effects for HR, VO2 and Workload at aerobic (AerT) and anaerobic (AnT) thresholds. Validity of RQA at both thresholds was assessed for HR, VO2 and Workload by Ordinary Least Products (OLP) regression, Typical Percentage Error (TE), Intraclass Correlation Coefficients (ICC) and the Bland Altman plots. No methods-by-groups interaction effects were detected for HR, VO2 and Workload at AerT and AnT. The OLP analysis showed that at both thresholds RQA and GE methods had very strong correlations (r >0.8) in all variables (HR, VO2 and Workload). Slope and intercept values always included the 1 and the 0, respectively. At AerT the TE ranged from 4.02% (5.48 bpm) to 10.47% (8.53 Watts) (HR and Workload, respectively) and in all variables ICC values were excellent (≥0.85). At AnT the TE ranged from 2.53% (3.98 bpm) to 6.64% (7.81 Watts) (HR and Workload, respectively) and in all variables ICC values were excellent (≥0.90). Therefore, RQA of HRV time series is a new valid approach to determine both ventilatory thresholds in individuals with different physical fitness levels, it can be used when gas analysis is not possible or not convenient

    VP6-SUMO Self-Assembly as Nanocarriers for Gastrointestinal Delivery

    Get PDF
    High proteolytic degradation and poor absorption through epithelial barriers are major challenges to successful oral delivery of therapeutics. Nanoparticle platforms can enhance drug stability and extend the residence time in gastrointestinal (GI) tract. However, drug delivery systems are often inactivated in acidic environment of stomach or suffer poor absorption from intestinal cells due to the mucus layer. To overcome these issues we developed a drug delivery system constituted by a protein construct made by a Rotavirus capsid protein (VP6) and the small ubiquitin-like modifier SUMO. This chimeric construct allows specificity towards intestinal cells, the Rotavirus natural target, combined by an enhanced stability given by the eukaryotic protein transporter SUMO. Furthermore SUMO can act as a molecular switch that facilitates import/export of its ligand to the nucleus, the hypersensitive subcellular site target of many cell killing therapies. In this paper we show that SUMO-VP6 constructs self-assembly into stable nanocarriers. SUMO-VP6 nanocarriers display ideal features for drug delivery: a small size and high monodispersity, a high stability in different pH conditions and a high uptake in the nuclear and cytoplasmic compartment of intestinal cells. These features make SUMO-VP6 nanocarriers a promising novel system for oral delivery of poorly soluble drugs
    • …
    corecore