59 research outputs found
Clinical Outcomes With a Repositionable Self-Expanding Transcatheter Aortic Valve Prosthesis: The International FORWARD Study
Background Clinical outcomes in large patient populations from real-world clinical practice with a next-generation self-expanding transcatheter aortic valve are lacking. Objectives This study sought to document the clinical and device performance outcomes of transcatheter aortic valve replacement (TAVR) with a next-generation, self-expanding transcatheter heart valve (THV) system in patients with severe symptomatic aortic stenosis (AS) in routine clinical practice. Methods The FORWARD (CoreValve Evolut R FORWARD) study is a prospective, single-arm, multinational, multicenter, observational study. An independent clinical events committee adjudicated safety endpoints based on Valve Academic Research Consortium-2 definitions. An independent echocardiographic core laboratory evaluated all echocardiograms. From January 2016 to December 2016, TAVR with the next-generation self-expanding THV was attempted in 1,038 patients with symptomatic, severe AS at 53 centers on 4 continents. Results Mean age was 81.8 ± 6.2 years, 64.9% were women, the mean Society of Thoracic Surgeons Predicted Risk of Mortality was 5.5 ± 4.5%, and 33.9% of patients were deemed frail. The repositioning feature of the THV was applied in 25.8% of patients. A single valve was implanted in the proper anatomic location in 98.9% of patients. The mean aortic valve gradient was 8.5 ± 5.6 mm Hg, and moderate or severe aortic regurgitation was 1.9% at discharge. All-cause mortality was 1.9%, and disabling stroke occurred in 1.8% at 30 days. The expected-to-observed early surgical mortality ratio was 0.35. A pacemaker was implanted in 17.5% of patients. Conclusions TAVR using the next-generation THV is clinically safe and effective for treating older patients with severe AS at increased operative risk. (CoreValve Evolut R FORWARD Study [FORWARD]; NCT02592369
Prevention of acute kidney injury and protection of renal function in the intensive care unit
Acute renal failure on the intensive care unit is associated with significant mortality and morbidity. To determine recommendations for the prevention of acute kidney injury (AKI), focusing on the role of potential preventative maneuvers including volume expansion, diuretics, use of inotropes, vasopressors/vasodilators, hormonal interventions, nutrition, and extracorporeal techniques. A systematic search of the literature was performed for studies using these potential protective agents in adult patients at risk for acute renal failure/kidney injury between 1966 and 2009. The following clinical conditions were considered: major surgery, critical illness, sepsis, shock, and use of potentially nephrotoxic drugs and radiocontrast media. Where possible the following endpoints were extracted: creatinine clearance, glomerular filtration rate, increase in serum creatinine, urine output, and markers of tubular injury. Clinical endpoints included the need for renal replacement therapy, length of stay, and mortality. Studies are graded according to the international Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) group system Several measures are recommended, though none carries grade 1A. We recommend prompt resuscitation of the circulation with special attention to providing adequate hydration whilst avoiding high-molecular-weight hydroxy-ethyl starch (HES) preparations, maintaining adequate blood pressure using vasopressors in vasodilatory shock. We suggest using vasopressors in vasodilatory hypotension, specific vasodilators under strict hemodynamic control, sodium bicarbonate for emergency procedures administering contrast media, and periprocedural hemofiltration in severe chronic renal insufficiency undergoing coronary intervention
MitraClip and left ventricular reverse remodelling: a strain imaging study
Aims: The purpose of this study is to identify echocardiography predictors of clinical response and reverse left ventricular (LV) remodelling in patients with functional mitral regurgitation (FMR) treated with MitraClip. Method and results: We retrospectively analysed 86 high surgical risk patients with severe FMR; of those, 58 were implanted a MitraClip, and 28 received medical treatment and served as controls. At baseline and at 1-year follow-up, we performed clinical and echocardiography evaluation to assess global longitudinal strain (GLS) and myocardial work [global work index (GWI), global constructive work (GCW), global wasted work (GWW), global work efficiency (GWE)]. Mitral regurgitation was significantly reduced after MitraClip implantation (3.7 ± 0.4 vs. 1.7 ± 0.8, P < 0.001), and the procedure was associated with improvement in brain natriuretic peptide levels (980 ± 1027 vs. 420 ± 338 pg/mL, P < 0.001), New York Heart Association class status (3.2 ± 0.55 vs. 2.0 ± 0.6, P < 0.001), 6-min walking test (233 ± 154 vs. 286 ± 114 m, P = 0.01) at follow-up and reduction of left ventricle end-systolic (LVESV) and left ventricle end-diastolic volumes (LVEDV) (152 ± 68 vs. 136 ± 43 mL, P = 0.004 & 219 ± 74 vs. 193 ± 66 mL, P = 0.001, respectively). MitraClip procedure was associated with improvement of LV performance and significant increase of GWI (607 ± 282 vs. 650 ± 260 mmHg%, P = 0.045) and GCW (854 ± 288 vs. 949 ± 325 mmHg%, P < 0.001). Baseline ejection fraction (EF), GLS, GWI, GCW, and effective regurgitant orifice area were the variables that were associated with reduction of LVEDV 1 year after intervention (P < 0.05 for all) and baseline GCW of the LV was the only variable associated with reduction of LVESV (P = 0.002). Receiver operating characteristic curve analysis identified that a GLS cut-off value of −8.65% (AUC 0.815, P = 0.007) was associated with a 20% reduction of the LVEDV with a sensitivity and specificity of 72% and 70%, respectively, and that a GCW cut-off value of 846 mmHg% (AUC 0.759, P = 0.007) was associated with a 10% reduction of LVESV with sensitivity and specificity 79% and 74%, respectively. Conclusions: Mitral valve repair with MitraClip has positive clinical and echocardiographic impact in patients with FMR 1 year after implantation. Preserved GLS and GCW values appear to be associated with LV reverse remodelling post intervention. © 2020 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of Cardiolog
Intermittent acute aortic valve regurgitation: A case report of a prosthetic valve dysfunction
Complications of any mechanical prosthesis include thrombus or pannus formation. In our case report we demonstrate that prosthetic aortic valve regurgitation due to pannus formation may be intermittent and non-cyclic in pattern and therefore not obvious at the time of original clinical examination. Under these conditions and as transesophageal echocardiography cannot be repeated promptly, transthoracic 2-D and Doppler echocardiography should be available at any time when symptoms occur and present the method of choice for acute patient evaluation. Thrombolysis seems to be the first treatment of choice in case of thrombus formation and re-do surgery in case of pannus formation
Transthoracic Doppler echocardiography assessment of left anterior descending artery flow in patients with previous anterior myocardial infarction
Aim: We tested the hypothesis that shortening of diastolic pressure half time (PHT) of left anterior descending (LAD) coronary flow in patients with old reperfused anterior myocardial infarction (MI) is related to the presence of permanent myocardial damage of the reperfused area. Methods and results: We studied 49 patients divided into: group A: 15 patients with previous anterior MI and evidence of myocardial scar; group B: 10 patients with previous anterior MI and no evidence of myocardial scar and group C: 24 patients without anterior MI. All patients underwent coronary angiography at least 6 months after an index event and any reperfusion procedure. Group A patients had lower PHT (199 ± 62 ms) than group C (377 ± 103 ms, p = 0.0001) and group B (316 ± 154 ms, p = 0.029) patients. No other LAD flow velocity parameter differed among the 3 groups. A PHT value of 265 ms discriminated patients with scarred anteriorwallwith a sensitivity of 79% and a specificity of 94% (0.88, p < 0.001). Conclusion: Shortening of the LAD flow diastolic PHT in patients with remote, reperfused anterior MI reflects scarred myocardial tissue in the anteroapical wall while patients who maintain diastolic wall thickness after an acute coronary syndrome have PHT similar to patients without anterior MI
- …