40 research outputs found
Recommended from our members
Oscillating shear index, wall shear stress and low density lipoprotein accumulation in human RCAs
This paper was presented at the 3rd Micro and Nano Flows Conference (MNF2011), which was held at the Makedonia Palace Hotel, Thessaloniki in Greece. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, Aristotle University of Thessaloniki, University of Thessaly, IPEM, the Process Intensification Network, the Institution of Mechanical Engineers, the Heat Transfer Society, HEXAG - the Heat Exchange Action Group, and the Energy Institute.Atherosclerosis shows predilection in regions of coronary arteries with hemodynamic
particularities as, local disturbances of Wall Shear Stress (WSS) in space and time, and locally high concentrations of lipoprotein. Six, image-based human deceased, Right Coronary Arteries (RCA) are used to elucidate, a) Low Density Lipoprotein (LDL) transport under steady flow and b) oscillating flow (no mass
transfer). A semi-permeable nature of the arterial wall computational model is incorporated with hydraulic conductivity and permeability treated as WSS dependent. The 3D reconstruction technique is a combination
of angiography and IVUS. LDL is elevated at locations where WSS is low. Under steady flow conditions the area-averaged normalized LDL concentration over the RCAs, using shear dependent water infiltration and endothelial permeability is 9.6 % higher than at entrance. However, under constant water infiltration and endothelial permeability this value is only 3.2 %. High Oscillating Shear Index (OSI) and low average WSS nearly co-locate. Approximately 630000 grid nodes proved to be sufficient enough to accurately describe the oscillating flow and the LDL concentration within the RCAs
Recommended from our members
Severity parameter and global importance factor of non-newtonian models in 3D reconstructed human left coronary artery
This paper was presented at the 3rd Micro and Nano Flows Conference (MNF2011), which was held at the Makedonia Palace Hotel, Thessaloniki in Greece. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, Aristotle University of Thessaloniki, University of Thessaly, IPEM, the Process Intensification Network, the Institution of Mechanical Engineers, the Heat Transfer Society, HEXAG - the Heat Exchange Action Group, and the Energy Institute.The capabilities and limitations of various molecular viscosity models, when testing Left Coronary Artery (LCA) tree, were analyzed via: molecular viscosity, local and global non-Newtonian importance factors, Wall Shear Stress (WSS) and Wall Shear Stress Gradient (WSSG). Seven non-Newtonian molecular viscosity models, plus the Newtonian one, were compared. Dense grid of 620000 nodes located, mostly, at near to low WSS flow regions (endothelium regions) is needed for current LCA application. The WSS
distribution yields a consistent LCA pattern for nearly all non-Newtonian models. High molecular viscosity, low WSS low WSSG values appear at proximal LCA regions at the outer walls of the major bifurcation. The global importance factor for the non-Newtonian power law model yields 76.7% (non-Newtonian flow), while for the Generalized power law model this value is 6.1% (Newtonian flow). The capabilities of the applied non-Newtonian law models appear at low strain rates. The Newtonian blood flow treatment is considered to be a good approximation at mid-and high-strain rates. In general, the non-Newtonian power law and the Generalized power law blood viscosity models are considered to approximate the molecular viscosity and WSS calculations in a more satisfactory way
Recommended from our members
Wall shear stress and low density lipoprotein concentration in stented arteries
This paper was presented at the 3rd Micro and Nano Flows Conference (MNF2011), which was held at the Makedonia Palace Hotel, Thessaloniki in Greece. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, Aristotle University of Thessaloniki, University of Thessaly, IPEM, the Process Intensification Network, the Institution of Mechanical Engineers, the Heat Transfer Society, HEXAG - the Heat Exchange Action Group, and the Energy Institute.Current computational analysis results quantify Wall Shear Stress (WSS) and its impact on Low Density Lipoprotein (LDL) concentration of a fully deployed straight artery stent. Atherosclerosis shows
predilection in arterial regions with hemodynamic particularities, as local disturbances of WSS in space, and locally high concentrations of lipoprotein. The WSS and subsequently the LDL distribution are important indicators of stent performance. A typical 6.0 mm diameter straight stented artery is used to elucidate the WSS and the LDL transport under steady flow conditions treating the blood as a non-Newtonian fluid. Struts are 50.0 % embedded into the arterial wall. Emphasis is placed in the LDL distribution at the upstream and downstream flow regions of each strut intersection. Reduced WSS values are observed towards outlet. At the strut intersections, high WSS values are observed possibly causing platelet activation. Prone to plaque development are flow regions located at specific strut intersections (mostly at the vicinity of the curved struts) where increased LDL concentration is observed. The maximum LDL concentration over the stented artery reaches a value of 3.8 % higher than that at the entrance. The concentration at distal to any strut region was higher than proximal to the strut
Influence of Oscillating Flow on LDL Transport and Wall Shear Stress in the Normal Aortic Arch
Lipid accumulation in the aortic wall is an important factor in the development of atherosclerosis. The Low Density Lipoprotein (LDL) at the surface of the endothelium in relation to Wall Shear Stress (WSS) in the normal human aortic arch under unsteady, normal flow and mass conditions was computationally analysed. Concave sides of the aortic arch exhibit, relatively to the convex ones, elevated LDL levels at the surface of the endothelium for all time steps. At the peak systolic velocity, the LDL level reaches a value 23.0% higher than that at entrance in the ascending-descending aorta region. The corresponding LDL levels at the surface of the endothelium for the near minimum entrance velocity instant reaches 26.0%. During the cardiac cycle, the highest area averaged normalized LDL taken up as compared to the lowest one is 0.69%. WSS plays an important role in the lipid accumulation. Low WSS regions are exposed to high LDL levels at the surface of the endothelium. Regions of elevated LDL levels do not necessarily co-locate to the sites of lowest WSS. The near wall paths of the velocities might be the most important factor for the elevated LDL levels at the surface of the endothelium
Computer-Aided Patient-Specific Coronary Artery Graft Design Improvements Using CFD Coupled Shape Optimizer
This study aims to (i) demonstrate the efficacy of a new surgical planning framework for complex cardiovascular reconstructions, (ii) develop a computational fluid dynamics (CFD) coupled multi-dimensional shape optimization method to aid patient-specific coronary artery by-pass graft (CABG) design and, (iii) compare the hemodynamic efficiency of the sequential CABG, i.e., raising a daughter parallel branch from the parent CABG in patient-specific 3D settings. Hemodynamic efficiency of patient-specific complete revascularization scenarios for right coronary artery (RCA), left anterior descending artery (LAD), and left circumflex artery (LCX) bypasses were investigated in comparison to the stenosis condition. Multivariate 2D constraint optimization was applied on the left internal mammary artery (LIMA) graft, which was parameterized based on actual surgical settings extracted from 2D CT slices. The objective function was set to minimize the local variation of wall shear stress (WSS) and other hemodynamic indices (energy dissipation, flow deviation angle, average WSS, and vorticity) that correlate with performance of the graft and risk of re-stenosis at the anastomosis zone. Once the optimized 2D graft shape was obtained, it was translated to 3D using an in-house “sketch-based” interactive anatomical editing tool. The final graft design was evaluated using an experimentally validated second-order non-Newtonian CFD solver incorporating resistance based outlet boundary conditions. 3D patient-specific simulations for the healthy coronary anatomy produced realistic coronary flows. All revascularization techniques restored coronary perfusions to the healthy baseline. Multi-scale evaluation of the optimized LIMA graft enabled significant wall shear stress gradient (WSSG) relief (~34%). In comparison to original LIMA graft, sequential graft also lowered the WSSG by 15% proximal to LAD and diagonal bifurcation. The proposed sketch-based surgical planning paradigm evaluated the selected coronary bypass surgery procedures based on acute hemodynamic readjustments of aorta-CA flow. This methodology may provide a rational to aid surgical decision making in time-critical, patient-specific CA bypass operations before in vivo execution
Cigarette smoke extract profoundly suppresses TNFα-mediated proinflammatory gene expression through upregulation of ATF3 in human coronary artery endothelial cells
Endothelial dysfunction caused by the combined action of disturbed flow, inflammatory mediators and oxidants derived from cigarette smoke is known to promote coronary atherosclerosis and increase the likelihood of myocardial infarctions and strokes. Conversely, laminar flow protects against endothelial dysfunction, at least in the initial phases of atherogenesis. We studied the effects of TNFα and cigarette smoke extract on human coronary artery endothelial cells under oscillatory, normal laminar and elevated laminar shear stress for a period of 72 hours. We found, firstly, that laminar flow fails to overcome the inflammatory effects of TNFα under these conditions but that cigarette smoke induces an anti-oxidant response that appears to reduce endothelial inflammation. Elevated laminar flow, TNFα and cigarette smoke extract synergise to induce expression of the transcriptional regulator activating transcription factor 3 (ATF3), which we show by adenovirus driven overexpression, decreases inflammatory gene expression independently of activation of nuclear factor-κB. Our results illustrate the importance of studying endothelial dysfunction in vitro over prolonged periods. They also identify ATF3 as an important protective factor against endothelial dysfunction. Modulation of ATF3 expression may represent a novel approach to modulate proinflammatory gene expression and open new therapeutic avenues to treat proinflammatory diseases
Computational comparison between Newtonian and non-Newtonian blood rheologies in stenotic vessels
This work aims at investigating the influence of non-Newtonian blood rheology on the hemodynamics of 3D patient-specific stenotic vessels, by means of a comparison of some numerical results with the Newtonian case. In particular, we consider two carotid arteries with severe stenosis and a stenotic coronary artery treated with a bypass graft, in which we virtually vary the degree of stenosis.We perform unsteady numerical simulations based on the Finite Element method using the Carreau-Yasuda model to describe the non-Newtonian blood rheology. Our results show that velocity, vorticity and wall shear stress distributions are moderately influenced by the non-Newtonian model in case of stenotic carotid arteries. On the other hand, we observed that a non-Newtonian model seems to be important in case of stenotic coronary arteries, in particular to compute the relative residence time which is greatly affected by the rheological model