3 research outputs found

    Cryo-EM and single-particle analysis with Scipion

    Full text link
    Cryo-electron microscopy has become one of the most important tools in biological research to reveal the structural information of macromolecules at near-atomic resolution. In single-particle analysis, the vitrified sample is imaged by an electron beam and the detectors at the end of the microscope column produce movies of that sample. These movies contain thousands of images of identical particles in random orientations. The data need to go through an image processing workflow with multiple steps to obtain the final 3D reconstructed volume. The goal of the image processing workflow is to identify the acquisition parameters to be able to reconstruct the specimen under study. Scipion provides all the tools to create this workflow using several image processing packages in an integrative framework, also allowing the traceability of the results. In this article the whole image processing workflow in Scipion is presented and discussed with data coming from a real test case, giving all the details necessary to go from the movies obtained by the microscope to a high resolution final 3D reconstruction. Also, the power of using consensus tools that allow combining methods, and confirming results along every step of the workflow, improving the accuracy of the obtained results, is discussed

    Algorithmic robustness to preferred orientations in single particle analysis by CryoEM

    Full text link
    The presence of preferred orientations in single particle analysis (SPA) by cryo-Electron Microscopy (cryoEM) is currently one of the hurdles preventing many structural analyses from yielding high-resolution structures. Although the existence of preferred orientations is mostly related to the grid preparation, in this technical note, we show that some image processing algorithms used for angular assignment and three-dimensional (3D) reconstruction are more robust than others to these detrimental conditions. We exemplify this argument with three different data sets in which the presence of preferred orientations hindered achieving a 3D reconstruction without artifacts or, even worse, a 3D reconstruction could never be achievedWe acknowledge support from “la Caixa” Foundation (Fellowship LCF/BQ/DI18/11660021. This project has received funding from the European Union’s Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement No. 713673. We also thank the financial support from the Spanish Ministry of Economy and Competitiveness through Grants BIO2016-76400-R(AEI/FEDER, UE) and SEV 2017-0712, the “Comunidad Autónoma de Madrid” through Grant: S2017/BMD-3817, Instituto de Salud Carlos III, PT17/ 0009/0010 (ISCIII-SGEFI/ERDF), European Union (EU) and Horizon 2020 through grants: CORBEL (INFRADEV-1-2014-1, Proposal: 654248), INSTRUCT-ULTRA (INFRADEV-03-2016-2017, Proposal: 731005), EOSC Life (INFRAEOSC-04-2018, Proposal: 824087), High- ResCells (ERC-2018-SyG, Proposal: 810057), IMpaCT (WIDESPREAD-03-2018 – Proposal: 857203), EOSC-Synergy (EINFRA-EOSC-5, Proposal: 857647), and iNEXT-Discovery (Proposal: 871037). The authors acknowledge the support and the use of resources of Instruct, a Landmark ESFRI projec

    Measurement of local resolution in electron tomography

    Full text link
    Resolution (global and local) is one of the most reported metrics of quality measurement in Single Particle Analysis (SPA). However, in electron tomography, the situation is different and its computation is not straightforward. Typically, resolution estimation is global and, therefore, reduces the assessment of a whole tomogram to a single number. However, it is known that tomogram quality is spatially variant. Still, up to our knowledge, a method to estimate local quality metrics in tomography is lacking. This work introduces MonoTomo, a method developed to estimate locally in a tomogram the highest reliable frequency component, expressed as a form of local resolution. The fundamentals lie in a local analysis of the density map via monogenic signals, which, in analogy to MonoRes, allows for local estimations. Results with experimental data show that the local resolution range that MonoTomo casts agrees with reported resolution values for experimental data sets, with the advantage of providing a local estimation. A range of applications of MonoTomo are suggested for further explorationThe author would like to express their gratitude to Dr. J.J. Fernandez for his interest, following and advice on this work. The authors would like to acknowledge economical support from The Spanish Ministry of Economy and Competitiveness through Grants BIO2016- 76400-R(AEI/FEDER, UE), the “Comunidad Autónoma de Madrid” through Grant: S2017/BMD-3817, and the European Union (EU) and Horizon 2020 through grant EOSCpilot (INFRADEV-04-2016, Proposal: 739563), INSTRUCT - ULTRA (INFRADEV-03-2016-2017, Proposal: 731005), EOSC-LIFE (INFRAEOSC-04-2018, Proposal: 824087) and HighResCells (ERC-2018-SyG, Proposal: 810057). The authors acknowledge the support and the use of resources of Instruct-ERI
    corecore