4 research outputs found

    Підвищення теплозахисту світлопрозорої огороджувальної конструкцій

    No full text
    Summary. Raising of problem. Today energy is expensive and prices are constantly rising, cladding home design must minimize the heat flow from the inside of the building. With new technologies came a sealed one plastic windows with singlechamber and triple-pane windows. Modern comforts and a periodic increase in the cost of energy and energy efficiency requirements walling forced to return two sash windows. Purpose. The increase of thermal resistance of translucent structures for filling window openings to prevent moisture condensation on their surface. Methods. For translucent enclosing structures for mass application in the construction of various buildings was calculated the thermal conductivity using the software package "Elcut 5". Results. The results received by using the thermographic camera are some differences in the indications of temperature from the calculated values obtained in the PC "Elcut". This can be explained by imperfection of the software package and also the accuracy of the accuracy of determining the surface temperature of the thermographic camera. Practical significanc.  For translucent enclosing structures for mass application of extra window frame increases the resistance to heat transfer, thus reduces heat loss, prevents condensation on the window and the formation of mildew on the surface of the slopes. The calculations in the software package "Elcut" demand perfection by introducing an additional factor taking into account the influence of the phenomenon of convection.Аннотация. Постановка проблемы. Учитывая, что сегодня энергоресурсы стоят достаточно дорого и цены на них постоянно растут, ограждающие конструкции дома должны быть сделаны таким образом, чтобы максимально снизить потери тепла изнутри здания и соответствовать требованиям нынешних норм по теплопроводности. С приходом новых технологий появились герметичные пластиковые окна с однокамерным, а со временем и двухкамерным стеклопакетом. Современные условия комфорта и периодические повышения стоимости энергоресурсов и требований энергоэффективности ограждающих конструкций заставляют возвращаться к двухрамным окнам. Цель. Повышение сопротивления теплопередачи для светопрозрачных конструкций заполнения оконных проемов с предотвращением конденсации влаги на их поверхности. Методика. Для ограждающих светопрозрачных конструкций массового применения при строительстве зданий различного назначения были выполнены расчёты на теплопроводность с помощью программного комплекса «Elcut 5». Результаты. Результаты полученные с помощью тепловизора имеют некоторые отличия в показаниях температурных величин от расчетных полученных в ПК «Elcut». Это можно объяснить несовершенством программного комплекса, а также погрешностью точности определения температуры поверхности тепловизором. Практичная значимость. Для ограждающих светопрозрачных конструкций массового применения установка дополнительной оконной рамы повышает сопротивление теплопередачи, тем самым снижает тепловые потери, предотвращает образование конденсата на окне и образование грибка на поверхности откосов. Расчеты в программном комплексе «Elcut» требуют совершенства путем введения дополнительного коэффициента учитывающего влияние явления конвекции.Анотація. Постановка проблеми. Враховуючи, що сьогодні енергоресурси коштують досить дорого і ціни на них постійно зростають, огороджувальні конструкції будинку повинні бути зроблені таким чином, щоб максимально знизити втрати тепла зсередини будівлі і відповідати вимогам чинних норм по теплопровідності. З приходом нових технологій з'явилися герметичні пластикові вікна з однокамерним, а з часом і двокамерним склопакетом. Сучасні умови комфорту та періодичні підвищення вартості енергоресурсів і вимог енергоефективності огороджувальних конструкцій змушують повертатися до колишніх дворамних вікон. Мета. Підвищення опору теплопередачі для світлопрозорих конструкцій заповнення віконних прорізів з метою запобігання конденсації вологи на їх поверхні. Методика. Для світлопрозорих огороджувальних конструкцій масового застосування при будівництві будівель різного призначення були виконані розрахунки на теплопровідність за допомогою програмного комплексу «Elcut 5». Результати. Результати отримані за допомогою тепловизора мають деякі відмінності в показаннях температурних величин від розрахункових отриманих у ПК «Elcut». Це можна пояснити недосконалістю програмного комплексу, а також похибкою точності визначення температури поверхні тепловізором. Практична значимість. Для світлопрозорих огороджувальних конструкцій масового застосування установка додаткової віконної рами підвищує опір теплопередачі, тим самим знижує теплові втрати, запобігає утворенню конденсату на вікні і утворення грибка на поверхні укосів. Розрахунки в програмному комплексі «Elcut» вимагають досконалості шляхом введення додаткового коефіцієнта, що буде враховувати вплив явища конвекції

    Удосконалення конструкцій тришарових навісних залізобетонних стінових панелей

    No full text
    Summary. Raising of problem. In construction there are different kinds of three-layer reinforced concrete cladding wall panels. The middle layer of these panels is a materials of heat-insulation (mineral wool, polymer, lightweight concrete), which have high thermal properties. The calculations were performed on the thermal conductivity using the software package Elcut 5" for main types of walling mass application in the construction of buildings for various purposes. Purpose. Improvement of structures reinforced concrete sandwich wall panels for mass application based on the results of the calculations of reduced resistance to heat transfer. Conclusion. The resistance of heat transfer panels with flexible links and panels with monolithic links between the layers and the middle layer of polystyrene on 1.35...2.1 higher than other variants structures. For the first temperature zone the minimum value of the resistance of heat transfer provides for panels with flexible links and the middle layer of expanded polystyrene (450...500 mm), extruded polystyrene foam (450...500 mm), and mineral wool (500 mm). And panels with monolithic links between the layers and the middle layer of polystyrene concrete (450...500 mm). For the second temperature zone the minimum value of thermal resistance of enclosing structures of residential and public buildings provide panels with flexible links and the middle layer of polystyrene (400...500 mm ), extruded polystyrene foam (400...500 mm), mineral wool (450...500 mm), and panels with monolithic links between the layers and the middle layer of polystyrene (400...500 mm).Аннотация. Постановка проблемы. В практике строительства используются различные виды трехслойных железобетонных ограждающих стеновых панелей. В качестве среднего слоя таких панелей применяют теплоизоляционные материалы (минераловатные, полимерные, легкие бетоны), обладающие высокими теплофизическими свойствами. Для основных типов ограждающих конструкций массового применения при строительстве зданий различного назначения были выполнены расчѐты на теплопроводность с помощью программного комплекса «Elcut 5». Цель. Усовершенствование конструкций трехслойных железобетонных стеновых панелей массового применения по результатам проведения анализа расчетов приведенного сопротивления теплопередачи. Вывод. Сопротивление теплопередачи для панели с гибкими связями и панелей с монолитной связью между слоями и средним слоем из полистиролбетона в 1,35…2,1 раза выше, чем у остальных вариантов конструкций. Минимальному значению сопротивления теплопередачи для первой температурной зоны удовлетворяют панели с гибкими связями и средним слоем из пенополистирола (450…500 мм), экструдированного пенополистирола (450…500 мм), и монераловаты (500 мм). А также панели с монолитной связью между слоями и средним слоем из полистиролбетона (450…500 мм). Для второй температурной зоны минимальное значение сопротивления теплопередачи ограждающей конструкции жилых и общественных зданий обеспечивают панели с гибкими связями и средним слоем из пенополистирола (400…500 мм ), экструдированного пенополистирола (400…500 мм), монераловаты (450…500 мм), и панели с монолитной связью между слоями и средним слоем из полистиролбетона (400…500 мм).Анотація. Постановка проблеми. У практиці будівництва використовуються різні види тришарових огороджувальних залізобетонних стінових панелей. В якості середнього шару таких панелей застосовують теплоізоляційні матеріали (мінераловатні, полімерні, легкі бетони), що володіють високими теплофізичними властивостями. Для основних типів огороджувальних конструкцій масового застосування при будівництві будівель різного призначення були виконані розрахунки на теплопровідність за допомогою програмного комплексу «Elcut 5». Мета. Удосконалення конструкцій тришарових залізобетонних стінових панелей масового застосування за результатами проведення аналізу розрахунків приведеного опору теплопередачі. Висновок. Опір теплопередачі для панелі з гнучкими в'язями і панелей з монолітною в'язю між шарами і середнім шаром з полістиролбетону в 1,35...2,1 рази вище, ніж у решти варіантів конструкцій. Мінімальному значенню опору теплопередачі для першої температурної зони задовольняють панелі з гнучкими в'язями і середнім шаром з пінополістиролу (450...500 мм), екструдованого пінополістиролу (450...500 мм), і мінераловати (500 мм). А також панелі з монолітною в'язю між шарами і середнім шаром з полістиролбетону (450...500 мм). Для другої температурної зони мінімальне значення опору теплопередачі огороджувальної конструкції житлових та громадських будівель забезпечують панелі з гнучкими в'язями і середнім шаром з пінополістиролу (400...500 мм), екструдованого пінополістиролу (400...500 мм), мінераловати (450...500 мм), і панелі з монолітною в'язю між шарами і середнім шаром з полістиролбетону (400...500 мм)

    Аналіз результатів дослідження тришарових залізобетонних балок за міцністю і тріщиностійкості

    No full text
    The analyzes the data of theoretical calculations according to two methods and the results of the conducted experiments show that the average of experimental values of bending cracking moments do not differ significantly from the data of calculations by deformation method ([7]) and significantly differof the values of the cracking moments obtained using the methods of [8].Приводится методика проведения испытаний опытных образцов балок. Представлены результаты испытаний прочности и трещиностойкости трехслойных железобетонных балок с теплоизоляционным слоем из полистиролбетона. Ключевые слова:трехслойная железобетонная балка, испытание, прочность, трещиностойкость.Наводиться методика проведення випробувань дослідних зразків балок. Представлені результати випробувань міцності і тріщиностійкості тришарових залізобетонних балок з теплоізоляційним шаром з полістиролбетону. Ключові слова: тришарова залізобетонна балка, випробування, міцність, тріщиностійкість
    corecore