31 research outputs found
Recommended from our members
Dosimetric comparison study between intensity modulated radiation therapy and three-dimensional conformal proton therapy for pelvic bone marrow sparing in the treatment of cervical cancer.
The objective was to compare intensity-modulated radiation therapy (IMRT) with 3D conformal proton therapy (3DCPT) in the treatment of cervical cancer. In particular, each technique's ability to spare pelvic bone marrow (PBM) was of primary interest in this study. A total of six cervical cancer patients (3 postoperative and 3 intact) were planned and analyzed. All plans had uniform 1.0 cm CTV-PTV margin and satisfied the 95% PTV with 100% isodose (prescription dose = 45 Gy) coverage. Dose-volume histograms (DVH) were analyzed for comparison. The overall PTV and PBM volumes were 1035.9 ± 192.2 cc and 1151.4 ± 198.3 cc, respectively. In terms of PTV dose conformity index (DCI) and dose homogeneity index (DHI), 3DCPT was slightly superior to IMRT with 1.00 ± 0.001, 1.01 ± 0.02, and 1.10 ± 0.02, 1.13 ± 0.01, respectively. In addition, 3DCPT demonstrated superiority in reducing lower doses (i.e., V30 or less) to PBM, small bowel and bladder. Particularly in PBM, average V10 and V20 reductions of 10.8% and 7.4% (p = 0.001 and 0.04), respectively, were observed. However, in the higher dose range, IMRT provided better sparing (> V30). For example, in small bowel and PBM, average reductions in V45 of 4.9% and 10.0% (p = 0.048 and 0.008), respectively, were observed. Due to its physical characteristics such as low entrance dose, spread-out Bragg peak and finite particle range of protons, 3DCPT illustrated superior target coverage uniformity and sparing of the lower doses in PBM and other organs. Further studies are, however, needed to fully exploit the benefits of protons for general use in cervical cancer
Proton therapy versus photon radiation therapy for the management of a recurrent desmoid tumor of the right flank: a case report
Abstract Desmoid tumors are benign mesenchymal tumors with a strong tendency for local recurrence after surgery. Radiotherapy improves local control following incomplete resection, but nearby organs at risk may limit the dose to the target volume. The patient in this report presented with a recurrent desmoid tumor of the right flank and underwent surgery with microscopically positive margins. Particular problems presented in this case included that the tumor bed was situated in close proximity to the liver and the right kidney and that the right kidney was responsible for 65% of the patient’s renal function. Intensity-modulated radiation therapy plans delivering 54 Gy necessarily exposed the right kidney to a V18 of 98% and the liver to a V30 of 55%. Proton therapy plans significantly reduced the right kidney V18 to 32% and the liver V30 to 28%. In light of this, the proton plan was utilized for treatment of this patient. Proton therapy was tolerated without gastrointestinal discomfort or other complaints. Twenty-four months after initiation of proton therapy, the patient is without clinical or radiographic evidence of disease recurrence. In this setting, the improved dose distribution associated with proton therapy allowed for curative treatment of a patient who arguably could not have been safely treated with intensity-modulated radiation therapy or other methods of conventional radiotherapy.</p
Recommended from our members
Dosimetric comparison study between intensity modulated radiation therapy and three-dimensional conformal proton therapy for pelvic bone marrow sparing in the treatment of cervical cancer.
The objective was to compare intensity-modulated radiation therapy (IMRT) with 3D conformal proton therapy (3DCPT) in the treatment of cervical cancer. In particular, each technique's ability to spare pelvic bone marrow (PBM) was of primary interest in this study. A total of six cervical cancer patients (3 postoperative and 3 intact) were planned and analyzed. All plans had uniform 1.0 cm CTV-PTV margin and satisfied the 95% PTV with 100% isodose (prescription dose = 45 Gy) coverage. Dose-volume histograms (DVH) were analyzed for comparison. The overall PTV and PBM volumes were 1035.9 ± 192.2 cc and 1151.4 ± 198.3 cc, respectively. In terms of PTV dose conformity index (DCI) and dose homogeneity index (DHI), 3DCPT was slightly superior to IMRT with 1.00 ± 0.001, 1.01 ± 0.02, and 1.10 ± 0.02, 1.13 ± 0.01, respectively. In addition, 3DCPT demonstrated superiority in reducing lower doses (i.e., V30 or less) to PBM, small bowel and bladder. Particularly in PBM, average V10 and V20 reductions of 10.8% and 7.4% (p = 0.001 and 0.04), respectively, were observed. However, in the higher dose range, IMRT provided better sparing (> V30). For example, in small bowel and PBM, average reductions in V45 of 4.9% and 10.0% (p = 0.048 and 0.008), respectively, were observed. Due to its physical characteristics such as low entrance dose, spread-out Bragg peak and finite particle range of protons, 3DCPT illustrated superior target coverage uniformity and sparing of the lower doses in PBM and other organs. Further studies are, however, needed to fully exploit the benefits of protons for general use in cervical cancer
Distortion of pulse waves propagating in some ferrite microstrip transmission lines
10.1163/156939303322519630Journal of Electromagnetic Waves and Applications17101441-1457JEWA