5 research outputs found

    <span style="font-size:12.0pt;mso-bidi-font-size: 14.0pt;line-height:115%;font-family:"Times New Roman";mso-fareast-font-family: "Times New Roman";mso-ansi-language:EN-IN;mso-fareast-language:EN-IN; mso-bidi-language:HI" lang="EN-IN">Establishment of embryonic cultures and somatic embryogenesis in callus culture of <i>guggul-Commiphora wightii</i> (Arnott.) Bhandari</span>

    No full text
    69-77<span style="font-size:12.0pt;mso-bidi-font-size: 14.0pt;line-height:115%;font-family:" times="" new="" roman";mso-fareast-font-family:="" "times="" roman";mso-ansi-language:en-in;mso-fareast-language:en-in;="" mso-bidi-language:hi"="" lang="EN-IN">Somatic embryogenesis in callus cultures of Commiphora wigitii (Arnott.) Bhandari was achieved. Though the frequency of explants producing embryonic culture was low, immature zygotic embryos were the only suitable explants to produce embryonic callus after reciprocal transfers on media containing 2,4,5-trichlorophenoxy acetic acid (0. 1 mgl-1) and kinetin(0.1mgl-1 ) or devoid of growth regulators. All other media failed to produce embryonic callus. Embryonic cells were small, densely filled with cytoplasm and isodiametric as compared to non-embryonic cells, which were large, elongated and vacuolated. Maximum growth of embryonic callus was recorded on modified MS medium (MS-2 medium) supplemented with BA (0.25 mgl-1) and IBA (0.1 mgl-1). MS-2 salts supported higher growth of callus as compared to tissues grown on B5 medium containing same concentrations of plant growth regulators. Exogenous medium nutrients had no effect on somatic embryo development whereas plant growth regulators had little effect. Asynchronously growing embryos formed plantlets regularly which were successfully transferred to the field conditions.</span

    A systematic review of the accuracy of ultrasound in the diagnosis of deep venous thrombosis in asymptomatic patients

    No full text
    Evaluation of the accuracy of ultrasound has yielded heterogeneous results. Our objective was to summarize the evidence on the accuracy of ultrasound compared to venography in asymptomatic patients, taking into account the variation due to threshold differences. Searches of journal table of contents, computer databases (Medline, Embase, Biomed, Cochrane) and conference proceedings were performed. A study was eligible if it prospectively compared ultrasound to venography for the diagnosis of DVT in asymptomatic patients. Data of studies selected for inclusion were extracted independently by two authors. High quality studies with consecutive patient enrollment, blind evaluation of the two techniques, and absence of verification bias are summarized as Level 1, while those not fulfilling one or more of these criteria are considered Level 2. Original study authors were contacted to confirm accuracy and to provide missing data. A pooled estimate of the accuracy of ultrasound was obtained according to the method of Moses and coworkers. This method gives a summary diagnostic odds ratio (DOR). The DOR is a single indicator of test performance. It varies between 0 and infinity and exceeds 1, only when ultrasound is more often positive in patients with DVT relative to those without DVT. Higher DOR indicates better discriminatory test performance. Thirty one studies were rated as potentially unbiased and graded as Level 1. The mean prevalence of DVT as determined by venography was 22%. In Level 1 studies, the odds of positive ultrasound in proximal veins was 379 times higher (95% confidence limits 65, 2,200) and in distal veins 32 times higher (7.5, 135) among patients with DVT than those without. Our results suggest that, particularly for proximal veins, ultrasound is accurate for the diagnosis of DVT in asymptomatic postoperative orthopedic patients. More research is needed in other clinical settings

    Sensory processing related to attention in children with ASD, ADHD, or typical development: results from the ELENA cohort

    No full text
    Autism-spectrum disorder (ASD) and attention-deficit hyperactivity disorder (ADHD) are early neurodevelopmental conditions that share clinical characteristics, raising important issues in clinical diagnosis. We aimed to compare (1) sensory processing in four groups of children: ASD alone, ASD + ADHD, ADHD alone, and typical development (TD) and (2) the association between sensory processing and attention in the three groups with neurodevelopmental disorders. Our sample included 120 children aged from 6 to 12&nbsp;years divided into four groups: ASD alone (N = 43), ASD + ADHD (N = 18), ADHD alone (N = 28), and TD (N = 31). Atypical sensory processing was more frequent in ASD and/or ADHD than in TD, without a significant difference between ASD and ADHD. However, the variance analysis of attention problems revealed differences between the ADHD and ASD groups. Thus, the rate of atypical sensory processing was comparable between the ASD and ADHD groups, suggesting that further studies are needed to explore atypical SP in all neurodevelopmental disorders
    corecore