47 research outputs found

    Physical activity measured by implanted devices predicts atrial arrhythmias and patient outcome: Results of IMPLANTED (Italian Multicentre Observational Registry on Patients With Implantable Devices Remotely Monitored)

    Get PDF
    Background--To determine whether daily physical activity (PA), as measured by implanted devices (through accelerometer sensor), was related to the risk of developing atrial arrhythmias during long-term follow-up in a population of heart failure (HF) patients with an implantable cardioverter defibrillator (ICD). Methods and Results--The study population was divided into 2 equally sized groups (PA cutoff point: 3.5 h/d) according to their mean daily PA recorded by the device during the 30- to 60-day period post-ICD implantation. Propensity score matching was used to compare 2 equally sized cohorts with similar characteristics between lower and higher activity patients. The primary end point was time free from the first atrial high-rate episode (AHRE) of duration 656 minutes. Secondary end points were: first AHRE 656 hours, first AHRE 6548 hours, and a combined end point of death or HF hospitalization. Data from 770 patients (65\ub115 years; 66% men; left ventricular ejection fraction 35\ub112%) remotely monitored for a median of 25 months were analyzed. A PA =3.5 h/d was associated with a 38% relative reduction in the risk of AHRE 656 minutes (72-month cumulative survival: 75.0% versus 68.1%; log rank P=0.025), and with a reduction in the risk of AHRE 656 hours, AHRE 6548 hours, and the combined end point of death or HF hospitalization (all P < 0.05). Conclusions--In HF patients with ICD, a low level of daily PA was associated with a higher risk of atrial arrhythmias, regardless of the patients' baseline characteristics. In addition, a lower daily PA predicted death or HF hospitalization

    Beta-Blocker Use in Older Hospitalized Patients Affected by Heart Failure and Chronic Obstructive Pulmonary Disease: An Italian Survey From the REPOSI Register

    Get PDF
    Beta (β)-blockers (BB) are useful in reducing morbidity and mortality in patients with heart failure (HF) and concomitant chronic obstructive pulmonary disease (COPD). Nevertheless, the use of BBs could induce bronchoconstriction due to β2-blockade. For this reason, both the ESC and GOLD guidelines strongly suggest the use of selective β1-BB in patients with HF and COPD. However, low adherence to guidelines was observed in multiple clinical settings. The aim of the study was to investigate the BBs use in older patients affected by HF and COPD, recorded in the REPOSI register. Of 942 patients affected by HF, 47.1% were treated with BBs. The use of BBs was significantly lower in patients with HF and COPD than in patients affected by HF alone, both at admission and at discharge (admission, 36.9% vs. 51.3%; discharge, 38.0% vs. 51.7%). In addition, no further BB users were found at discharge. The probability to being treated with a BB was significantly lower in patients with HF also affected by COPD (adj. OR, 95% CI: 0.50, 0.37-0.67), while the diagnosis of COPD was not associated with the choice of selective β1-BB (adj. OR, 95% CI: 1.33, 0.76-2.34). Despite clear recommendations by clinical guidelines, a significant underuse of BBs was also observed after hospital discharge. In COPD affected patients, physicians unreasonably reject BBs use, rather than choosing a β1-BB. The expected improvement of the BB prescriptions after hospitalization was not observed. A multidisciplinary approach among hospital physicians, general practitioners, and pharmacologists should be carried out for better drug management and adherence to guideline recommendations

    New-onset ventricular tachycardia after cardiac resynchronization therapy

    No full text
    It is well established that coronary artery disease with healed myocardial infarction is the most common backdrop for ventricular tachycardia (VT). Although the clinical benefits of biventricular pacing (BivP) in the treatment of severe heart failure are well documented, exact relation with ventricular arrhythmias remains still unclear.We describe a case of a patient, whitout a previous history of arrhythmic episodes, in which the onset of several episodes of VT presented immediatly after cardiac resynchronization therapy (CRT) and did not occur after BivP discontinuation

    Pacing and implantable cardioverter-defibrillator transvenous lead extraction

    No full text
    During the last 20 years, the transvenous techniques for the extraction of chronically implanted pacing (PL) and defibrillating leads (DL) achieved a high success rate. However the procedures are often complex and are associated with a small but significant risk. The operators' experience and the availability of different approaches for difficult cases seem to affect both the results and the complications. This paper represents a review of indications, techniques and results of a 10-year experience in the field of transvenous lead extraction. Since January 1997, extraction was attempted in 1330 leads; among these 1137 were successfully extracted with the standard mechanical approach (success rate 85.4%); in 12 leads was performed a partial extraction (0.9%) and 1 was inapplicable (0.07%). The jugular approach was performed in 180 leads (164 PL and 16 DL): 39 were intravascular free-floating leads (38 PL and 1 DL) and 141 were difficult exposed leads (126 PL and 15 DL) allowing extraction in 178/180 (98.8%) cases. After this approach, the final results were: total extraction 98.88%, partial extraction 0.90%, unextracted 0.15%, and not applicable 0.07%. Major complications occurred in 4 cases (0.3%) and were cardiac tamponade (2 underwent successful pericardiocentesis, 1 surgical repair, and 1 patient died). No complications were directly related to the jugular approach. In conclusion, transvenous lead extraction is an effective and safe procedure. The success rate and the incidence of complications are highly affected by the staff experience. The use of the jugular approach, in the presence of free-floating or difficult exposed leads, increases both safety and success rate
    corecore