20 research outputs found

    Modelling and Measurement of Charge Transfer in Multiple GEM Structures

    Get PDF
    Measurements and numerical simulations on the charge transfer in Gas Electron Multiplier (GEM) foils are presented and their implications for the usage of GEM foils in Time Projection Chambers are discussed. A small test chamber has been constructed and operated with up to three GEM foils. The charge transfer parameters derived from the electrical currents monitored during the irradiation with an Fe-55 source are compared with numerical simulations. The performance in magnetic fields up to 2 T is also investigated.Comment: 21 pages, 16 figures, submitted to NIM-

    Polarization and Polarimetry at HERA

    No full text

    Polarisation at HERA - Reanalysis of the HERA II Polarimeter Data -

    No full text
    In this technical note we briefly present the analysis of the HERA polarimeters (transversal and longitudinal) as of summer 2011. We present the final reanalysis of the TPOL data, and discuss the systematic uncertainties. A procedure to combine and average LPOL and TPOL data is presented