15,702 research outputs found

    Dispersion analysis techniques within the space vehicle dynamics simulation program

    Get PDF
    The Space Vehicle Dynamics Simulation (SVDS) program was evaluated as a dispersion analysis tool. The Linear Error Analysis (LEA) post processor was examined in detail and simulation techniques relative to conducting a dispersion analysis using the SVDS were considered. The LEA processor is a tool for correlating trajectory dispersion data developed by simulating 3 sigma uncertainties as single error source cases. The processor combines trajectory and performance deviations by a root-sum-square (RSS process) and develops a covariance matrix for the deviations. Results are used in dispersion analyses for the baseline reference and orbiter flight test missions. As a part of this study, LEA results were verified as follows: (A) Hand calculating the RSS data and the elements of the covariance matrix for comparison with the LEA processor computed data. (B) Comparing results with previous error analyses. The LEA comparisons and verification are made at main engine cutoff (MECO)

    Investigation of light source and scattering medium related to vapor-screen flow visualization in a supersonic wind tunnel

    Get PDF
    Methods for increasing the radiant in light sheets used for vapor screen set-ups were investigated. Both high-pressure mercury arc lamps and lasers were considered. Pulsed operation of the air-cooled 1-kW lamps increased the light output but decreased reliability. An ellipsoidal mirror improved the output of the air-cooled lamps by concentrating the light but increased the complexity of the housing. Water-cooled-4-kW lamps coupled with high-aperture Fresnel lenses provided reasonable improvements over the air-cooled lamps. Fanned laser beams measurements of scattered light versus dew point made in conjunction with successful attempts to control the fluid injection. A number of smoke generators are described and test results comparing smoke and vapor screens are shown. Finally, one test included a periscope system to relay the image to a camera outside the flow

    Video photographic considerations for measuring the proximity of a probe aircraft with a smoke seeded trailing vortex

    Get PDF
    Considerations for acquiring and analyzing 30 Hz video frames from charge coupled device (CCD) cameras mounted in the wing tips of a Beech T-34 aircraft are described. Particular attention is given to the characterization and correction of optical distortions inherent in the data

    Dynamic Moire Methods for Detection of Loosened Space Shuttle Tiles

    Get PDF
    Moire fringe methods for detecting loose space shuttle tiles were investigated with a test panel consisting of a loose tile surrounded by four securely bonded tiles. The test panel was excited from 20 to 150 Hz with in-plane sinusoidal acceleration of 2 g (peak). If the shuttle orbiter can be subjected to periodic excitation of 1 to 2 g (peak) and rigid-body periodic displacements do not mask the change in the Moire pattern due to tile looseness, then the use of projected Moire fringes to detect out-of-plane rockin appears to be the most viable indicator of tile looseness since no modifications to the tiles are required

    Is There Enhanced Depletion of Gas-Phase Nitrogen in Moderately Reddened Lines of Sight?

    Full text link
    We report on the abundance of interstellar neutral nitrogen (NI) for 30 sightlines, using data from the Far Ultraviolet Spectroscopic Explorer (FUSE) and the Hubble Space Telescope (HST). NI column densities are derived by measuring the equivalent widths of several ultraviolet absorption lines and subsequently fitting those to a curve of growth. We find a mean interstellar N/H of 51+/-4 ppm. This is below the mean found by Meyer et al. of 62(+4,-3) ppm (adjusted for a difference in f-values). Our mean N/H is similar, however, to the (f-value adjusted) mean of 51+/-3 ppm found by Knauth et al. for a larger sample of sightlines with larger hydrogen column densities comparable to those in this study. We discuss the question of whether or not nitrogen shows increased gas-phase depletion in lines of sight with column densities log(H_tot) >~ 21, as claimed by Knauth et al. The nitrogen abundance in the line of sight toward HD 152236 is particularly interesting. We derive very small N/H and N/O ratios for this line of sight that may support a previous suggestion that members of the Sco OB1 association formed from an N-deficient region.Comment: Accepted in The Astrophysical Journal, 9/2006 (expected pub. date: 1/2007) 38 pages, 5 figures (4 color

    Mode shape analysis using a commercially available peak store video frame buffer

    Get PDF
    Time exposure photography, sometimes coupled with strobe illumination, is an accepted method for motion analysis that bypasses frame by frame analysis and resynthesis of data. Garden variety video cameras can now exploit this technique using a unique frame buffer that is a non-integrating memory that compares incoming data with that already stored. The device continuously outputs an analog video signal of the stored contents which can then be redigitized and analyzed using conventional equipment. Historically, photographic time exposures have been used to record the displacement envelope of harmonically oscillating structures to show mode shape. Mode shape analysis is crucial, for example, in aeroelastic testing of wind tunnel models. Aerodynamic, inertial, and elastic forces can couple together leading to catastrophic failure of a poorly designed aircraft. This paper will explore the usefulness of the peak store device as a videometric tool and in particular discuss methods for analyzing a targeted vibrating plate using the 'peak store' in conjunction with calibration methods familiar to the close-range videometry community. Results for the first three normal modes will be presented

    ICONA: Inter Cluster ONOS Network Application

    Full text link
    Several Network Operating Systems (NOS) have been proposed in the last few years for Software Defined Networks; however, a few of them are currently offering the resiliency, scalability and high availability required for production environments. Open Networking Operating System (ONOS) is an open source NOS, designed to be reliable and to scale up to thousands of managed devices. It supports multiple concurrent instances (a cluster of controllers) with distributed data stores. A tight requirement of ONOS is that all instances must be close enough to have negligible communication delays, which means they are typically installed within a single datacenter or a LAN network. However in certain wide area network scenarios, this constraint may limit the speed of responsiveness of the controller toward network events like failures or congested links, an important requirement from the point of view of a Service Provider. This paper presents ICONA, a tool developed on top of ONOS and designed in order to extend ONOS capability in network scenarios where there are stringent requirements in term of control plane responsiveness. In particular the paper describes the architecture behind ICONA and provides some initial evaluation obtained on a preliminary version of the tool.Comment: Paper submitted to a conferenc

    Evolution of magnetic polarons and spin-carrier interactions through the metal-insulator transition in Eu1−x_{1-x}Gdx_{x}O

    Full text link
    Raman scattering studies as functions of temperature, magnetic field, and Gd-substitution are used to investigate the evolution of magnetic polarons and spin-carrier interactions through the metal-insulator transition in Eu1−x_{1-x}Gdx_{x}O. These studies reveal a greater richness of phase behavior than have been previously observed using transport measurements: a spin-fluctuation-dominated paramagnetic (PM) phase regime for T >> T∗^{*} >> TC_{C}, a two-phase regime for T << T∗^{*} in which magnetic polarons develop and coexist with a remnant of the PM phase, and an inhomogeneous ferromagnetic phase regime for T << TC_{C}

    Precision determination of absolute neutron flux

    Full text link
    A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using a method of an alpha-gamma counter. The method involves only the counting of measured rates and is independent of neutron cross sections, decay chain branching ratios, and neutron beam energy. For the measurement, a target of 10B-enriched boron carbide totally absorbed the neutrons in a monochromatic beam, and the rate of absorbed neutrons was determined by counting 478keV gamma rays from neutron capture on 10B with calibrated high-purity germanium detectors. A second measurement based on Bragg diffraction from a perfect silicon crystal was performed to determine the mean de Broglie wavelength of the beam to a precision of 0.024 %. With these measurements, the detection efficiency of a neutron monitor based on neutron absorption on 6Li was determined to an overall uncertainty of 0.058 %. We discuss the principle of the alpha-gamma method and present details of how the measurement was performed including the systematic effects. We also describe how this method may be used for applications in neutron dosimetry and metrology, fundamental neutron physics, and neutron cross section measurements.Comment: 44 page
    • …
    corecore