22 research outputs found

    Responses of Auditory Nerve and Anteroventral Cochlear Nucleus Fibers to Broadband and Narrowband Noise: Implications for the Sensitivity to Interaural Delays

    Get PDF
    The quality of temporal coding of sound waveforms in the monaural afferents that converge on binaural neurons in the brainstem limits the sensitivity to temporal differences at the two ears. The anteroventral cochlear nucleus (AVCN) houses the cells that project to the binaural nuclei, which are known to have enhanced temporal coding of low-frequency sounds relative to auditory nerve (AN) fibers. We applied a coincidence analysis within the framework of detection theory to investigate the extent to which AVCN processing affects interaural time delay (ITD) sensitivity. Using monaural spike trains to a 1-s broadband or narrowband noise token, we emulated the binaural task of ITD discrimination and calculated just noticeable differences (jnds). The ITD jnds derived from AVCN neurons were lower than those derived from AN fibers, showing that the enhanced temporal coding in the AVCN improves binaural sensitivity to ITDs. AVCN processing also increased the dynamic range of ITD sensitivity and changed the shape of the frequency dependence of ITD sensitivity. Bandwidth dependence of ITD jnds from AN as well as AVCN fibers agreed with psychophysical data. These findings demonstrate that monaural preprocessing in the AVCN improves the temporal code in a way that is beneficial for binaural processing and may be crucial in achieving the exquisite sensitivity to ITDs observed in binaural pathways

    Different degrees of malnutrition and immunological alterations according to the aetiology of cirrhosis: a prospective and sequential study

    Get PDF
    OBJECTIVES: In this work we investigated how immunological dysfunction and malnutrition interact in alcoholic and viral aetiologies of cirrhosis. METHODS: To investigate the matter, 77 cirrhotic patients divided in three aetiologies [Alcohol, HCV and Alcohol + HCV) and 32 controls were prospectivelly and sequentially studied. Parameters of humoral immunity (Components 3 and 4 of seric complement and immunoglobulins A M, G and E) and of cellular immunity (total leukocytes and lymphocytes in peripheral blood, T lymphocytes subpopulations, CD4+ and CD8+, CD4+/CD8+ ratio and intradermic tests of delayed hypersensitivity), as well as nutrititional parameters: anthropometric measures, serum albumin and transferrin were evaluated. RESULTS: Multiple statistical comparisons showed that IgM was higher in HCV group; IgG was significantly elevated in both HCV and Alcohol + HCV, whereas for the Alcohol group, IgE was found at higher titles. The analysis of T- lymphocytes subpopulations showed no aetiologic differences, but intradermic tests of delayed hypersensitivity did show greater frequency of anergy in the Alcohol group. For anthropometric parameters, the Alcohol +HCV group displayed the lowest triceps skinfold whereas creatinine – height index evaluation was more preserved in the HCV group. Body mass index, arm muscle area and arm fat area showed that differently from alcohol group, the HCV group was similar to control. CONCLUSION: Significant differences were found among the main aetiologies of cirrhosis concerning immunological alterations and nutritional status: better nutrition and worse immunology for HCV and vice-versa for alcohol

    Assessing circadian rhythms in propofol PK and PD during prolonged infusion in ICU patients

    Get PDF
    This study evaluates possible circadian rhythms during prolonged propofol infusion in patients in the intensive care unit. Eleven patients were sedated with a constant propofol infusion. The blood samples for the propofol assay were collected every hour during the second day, the third day, and after the termination of the propofol infusion. Values of electroencephalographic bispectral index (BIS), arterial blood pressure, heart rate, blood oxygen saturation and body temperature were recorded every hour at the blood collection time points. A two-compartment model was used to describe propofol pharmacokinetics. Typical values of the central and peripheral volume of distribution and inter-compartmental clearance were VC = 27.7 l, VT = 801 l, and CLD = 2.73 l/min. The systolic blood pressure (SBP) was found to influence the propofol metabolic clearance according to Cl (l/min) = 2.65·(1 − 0.00714·(SBP − 135)). There was no significant circadian rhythm detected with respect to propofol pharmacokinetics. The BIS score was assessed as a direct effect model with EC50 equal 1.98 mg/l. There was no significant circadian rhythm detected within the BIS scores. We concluded that the light–dark cycle did not influence propofol pharmacokinetics and pharmacodynamics in intensive care units patients. The lack of night–day differences was also noted for systolic blood pressure, diastolic blood pressure and blood oxygenation. Circadian rhythms were detected for heart rate and body temperature, however they were severely disturbed from the pattern of healthy patients

    Multidimensional Characterization and Differentiation of Neurons in the Anteroventral Cochlear Nucleus

    Get PDF
    Multiple parallel auditory pathways ascend from the cochlear nucleus. It is generally accepted that the origin of these pathways are distinct groups of neurons differing in their anatomical and physiological properties. In extracellular in vivo recordings these neurons are typically classified on the basis of their peri-stimulus time histogram. In the present study we reconsider the question of classification of neurons in the anteroventral cochlear nucleus (AVCN) by taking a wider range of response properties into account. The study aims at a better understanding of the AVCN's functional organization and its significance as the source of different ascending auditory pathways. The analyses were based on 223 neurons recorded in the AVCN of the Mongolian gerbil. The range of analysed parameters encompassed spontaneous activity, frequency coding, sound level coding, as well as temporal coding. In order to categorize the unit sample without any presumptions as to the relevance of certain response parameters, hierarchical cluster analysis and additional principal component analysis were employed which both allow a classification on the basis of a multitude of parameters simultaneously. Even with the presently considered wider range of parameters, high number of neurons and more advanced analytical methods, no clear boundaries emerged which would separate the neurons based on their physiology. At the current resolution of the analysis, we therefore conclude that the AVCN units more likely constitute a multi-dimensional continuum with different physiological characteristics manifested at different poles. However, more complex stimuli could be useful to uncover physiological differences in future studies

    Lawson criterion for ignition exceeded in an inertial fusion experiment

    Get PDF
    For more than half a century, researchers around the world have been engaged in attempts to achieve fusion ignition as a proof of principle of various fusion concepts. Following the Lawson criterion, an ignited plasma is one where the fusion heating power is high enough to overcome all the physical processes that cool the fusion plasma, creating a positive thermodynamic feedback loop with rapidly increasing temperature. In inertially confined fusion, ignition is a state where the fusion plasma can begin "burn propagation" into surrounding cold fuel, enabling the possibility of high energy gain. While "scientific breakeven" (i.e., unity target gain) has not yet been achieved (here target gain is 0.72, 1.37 MJ of fusion for 1.92 MJ of laser energy), this Letter reports the first controlled fusion experiment, using laser indirect drive, on the National Ignition Facility to produce capsule gain (here 5.8) and reach ignition by nine different formulations of the Lawson criterion

    Statistical Analyses of Temporal Information in Auditory Brainstem Responses to Tones in Noise: Correlation Index and Spike-distance Metric

    No full text
    Gai and Carney (J Neurophysiol 96:2451–2464, 2006) previously explored the detection of tones in noise based on responses in the anteroventral cochlear nucleus; that study focused on temporal information in discharge reliability and analyses of neural responses related to the fine structure or envelope of the stimulus. Two additional temporal approaches, the correlation index (Joris et al., Hearing Res 216–217:19–30, 2006) and the spike-distance metric (Victor and Purpura, J Neurophysiol 76:1310–1326, 1996; Netw Comput Neural Syst 8:127–164, 1997), are tested in the present study. Trends in the correlation index as a function of stimulus level are similar to those of the synchronization coefficient (also called the vector strength) when the tone is presented alone. However, the present study found that trends in the correlation index did not agree with those of the synchronization coefficient for tones presented with relatively high-level background noise. Instead, trends in the correlation index generally agreed with those of the temporal reliability metric discussed in Gai and Carney (J Neurophysiol 96:2451–2464, 2006); that is, the correlation index decreased with increased tone level in the presence of relatively high-level background noise. The spike-distance metric, which was based on absolute spike times or on interspike intervals, was compared to the temporal measures described above, which were generally based on relative spike times. The results confirm that the spike-distance metric is not an optimal temporal metric. In addition, absolute spike times of primary-like responses generally contained much less temporal information than absolute spike times of chopper response types. The present study highlights the importance of relative spike-timing information as characterized by traditional and novel temporal measures
    corecore