31 research outputs found

    More accurate systolic blood pressure measurement is required for improved hypertension management: a perspective

    No full text
    Meir Nitzan,1 Itzchak Slotki,2 Linda Shavit2 1Department of Applied Physics/Electro-Optics, Jerusalem College of Technology, 2Department of Nephrology, Shaare Zedek Medical Center, Jerusalem, Israel Abstract: The commonly used techniques for systolic blood pressure (SBP) and diastolic blood pressure (DBP) measurement are the auscultatory Korotkoff-based sphygmomanometry and oscillometry. The former technique is relatively accurate but is limited to a physician’s office because its automatic variant is subject to noise artifacts. Consequently, the Korotkoff-based measurement overestimates the blood pressure in some patients due to white coat effect, and because it is a single measurement, it cannot properly represent the variable blood pressure. Automatic oscillometry can be used at home by the patient and is preferred even in clinics. However, the technique’s accuracy is low and errors of 10–15 mmHg are common. Recently, we have developed an automatic technique for SBP measurement, based on an arm pressure cuff and a finger photoplethysmographic probe. The technique was found to be significantly more accurate than oscillometry, and comparable to the Korotkoff-based technique, the reference-standard for non-invasive blood pressure measurements. The measurement of SBP is a mainstay for the diagnosis and follow-up of hypertension, which is a major risk factor for several adverse events, mainly cardiovascular. Lowering blood pressure evidently reduces the risk, but excessive lowering can result in hypotension and consequently hypoperfusion to vital organs, since blood pressure is the driving force for blood flow. Erroneous measurement by 10 mmHg can lead to a similar unintended reduction of SBP and may adversely affect patients treated to an SBP of 120–130 mmHg. In particular, in elderly patients, unintended excessive reduction of blood pressure due to inaccurate SBP measurement can result in cerebral hypoperfusion and consequent cognitive decline. By using a more accurate technique for automatic SBP measurement (such as the photoplethysmographic-based technique), the optimal blood pressure target can be achieved with lower risk for hypotension and its adverse events. Keywords: oscillometry, hypotension, cognitive impairment, photoplethysmograph

    Supplementary Material for: Influence of Minimal Changes in Preoperative Renal Function on Outcomes of Cardiac Surgery

    No full text
    <b><i>Background/Aims:</i></b> Cardiovascular morbidity and mortality are high in patients with chronic kidney disease. We evaluated the influence of small differences in preoperative kidney function on mortality and complications following cardiac surgery. <b><i>Methods:</i></b> This is an observational study that included adult patients undergoing cardiac surgery. Preoperative estimated glomerular filtration rate (eGFR) was estimated by the 4-component Modification of Diet in Renal Disease (MDRD) and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations based on preoperative creatinine levels. For analysis, patients were divided into groups according to their preoperative creatinine (0.2 mg/dl increments) and eGFR levels (15–30 ml/min/1.73 m<sup>2</sup> decrements). <b><i>Results:</i></b> Data on 5,340 patients were analyzed. A significant increase in postoperative mortality was demonstrated with preoperative creatinine at high-normal versus low-normal values (OR 1.7, 95% CI: 1–2.5; p = 0.02). For preoperative creatinine >1.2 mg/dl, adjusted OR for in-hospital mortality increased stepwise with every 0.2-mg/dl increment of creatinine. In addition, a statistically significant increment of mortality was detected with every 15-ml/min/1.73 m<sup>2</sup> decrement in preoperative eGFR. <b><i>Conclusions:</i></b> Minimal changes of preoperative kidney function are associated with a substantial increase in the risk of mortality and morbidity following cardiac surgery. Even within the ‘normal’ range, minimal increases in serum creatinine levels are associated with increased risk of adverse events postoperatively
    corecore