28 research outputs found

    Autonomous Retroflexion of a Magnetic Flexible Endoscope

    Get PDF
    Retroflexion during colonoscopy is typically only practiced in the wider proximal and distal ends of the large intestine owing to the stiff nature of the colonoscope. This inability to examine the proximal side of the majority of colon folds contributes to today's suboptimal colorectal cancer detection rates. We have developed an algorithm for autonomous retroflexion of a flexible endoscope that is actuated magnetically from the tip. The magnetic wrench applied on the tip of the endoscope is optimized in real time with data from pose detection to compute motions of the actuating magnet. This is the first example of a completely autonomous maneuver by a magnetic endoscope for exploration of the gastrointestinal tract. The proposed approach was validated in plastic tubes of various diameters with a success rate of 98.8% for separation distances up to 50 mm. Additionally, a set of trials was conducted in an excised porcine colon observing a success rate of 100% with a mean time of 19.7 s. In terms of clinical safety, the maximum stress that is applied on the colon wall with our methodology is an order of magnitude below what would damage tissue

    Laparoscopic Camera Based on an Orthogonal Magnet Arrangement

    Get PDF
    In this letter, we present for the first time a magnetic anchoring-actuation link with an auto-flip feature. This orthogonal magnetic arrangement relies on the placement of two permanent magnets such that their magnetic moments are respectfully orthogonal. Though the arrangement may have many applications, in this study we integrate it in a small factor magnetic camera for minimally invasive procedures. Upon insertion through a trocar incision, the 5.5 mm diameter and 35 mm length magnetic camera is coupled with an external robotic controller and displaced from the port thus preventing clutter of the surgical workspace. The device allows for manual lateral translation as well as robotically controlled tilt and pan, resulting in four degrees of freedom. The auto-flip feature prevents the need for image adjustment in software as the camera tilts through its hemispherical workspace. A static model that relates an input external control tilt and output camera tilt has been developed and validated. Favorable results during bench and canine cadaver evaluation suggest promise for the proposed magnetic camera to improve the state of art in minimally invasive surgical procedures

    Is There an Economical Running Technique? A Review of Modifiable Biomechanical Factors Affecting Running Economy

    Get PDF

    Towards Recovering a Lost Degree of Freedom in Magnet-Driven Robotic Capsule Endoscopy

    No full text
    Flexible endoscopy, a procedure during which an operator pushes a semi-rigid endoscope through a patient’s gastrointestinal tract, has been the gold-standard screening method for colon cancer screening (colonoscopy) for over 50 years. Owing to the large amounts of tissue stress that result from the need for transmitting a force to the tip of the endoscope while the device wraps through the bowel, implementing a front-actuated endoscopy system has been a popular area of research [1]. The pursuit of such a concept was accelerated by the advent of ingestible capsule endoscopes, which, since then, have been augmented by researchers to include therapeutic capabilities, modalities for maneuverability, amongst other diagnostic functions [2]. One of the more common approaches investigated has been the use of magnetic fields to apply forces and torques to steer the tip of an endoscope [3]. Recent efforts in magnetic actuation have resulted in the use of robot manipulators with permanent magnets at their end effectors that are used to manipulate endoscopes with embedded permanent magnets. Recently, we implemented closed loop control of a tethered magnetic capsule by using real-time magnetic localization and the linearization of a magnetic wrench applied to the capsule by the actuating magnet [4]. This control was implemented in 2 degrees-of-freedom (DoF) in position (in the horizontal plane) and 2 DoF in orientation (panning and tilting). One DoF in position is lost owing to the tethered capsule being actuated in air and thus lacking a restoring force to counter the high field gradient. The 3rd orientation DoF is lost owing to the axial symmetry of the permanent magnet in the capsule; this prevents the application of torque in the axial direction and thus controlled roll and introduces a singularity in the capsule’s actuation. Although another dipole could be used to eliminate this singularity, this would complicate both the actuation and localization methods. In this manuscript, we consider the consequences of the embedded magnet (EM) being radially offset from the center of the capsule while being manipulated by an external actuating magnet (AM).We have developed a tethered capsule endoscope that contains a cylindrical EM (11.11 mm in length and diameter) with a residual flux density of 1.48 T that is offset by 1.85 mm from the center of the capsule; a distance that is less than 10% of the capsule diameter. Our investigation into the topic results from repeated observation of the capsule’s preference to align such that the internal magnet is closest to the actuating magnet (AM). The AM is a cylindrical magnet (101.6 mm in length and diameter) with a residual flux density of 1.48 T that is mounted at the end effector of a 6 DoF manipulator, as seen in Figure 1. In this manuscript, we evaluate the torqueing effects of the presence of this magnet offset with the goal of determining whether the torque effect is negligible, or impacts capsule motion and thus can potentially be used for the benefit of endoscope manipulation. A concept schematic of this effect is shown in Figure 2. A discussion of how to use this torque is beyond the scope of this manuscript. To the authors’ knowledge, the use of such concept in permanent-magnet based control has not been investigated
    corecore