33 research outputs found

    Enlargement of the bony orbit by orbital recurrence of choroidal melanoma 21 years after enucleation

    Get PDF
    A case is presented of a 58-year-old retarded male with a 6 cm, painless, hard, pigmented tumor filling the left orbit completely, after enucleation 21 years previously for retinal detachment, glaucoma and no light perception. CT scan and MRI revealed, besides the tumor, an outspoken enlargement of the bony orbit with thinning of the orbital walls. A biopsy showed a spindle B cell melanoma. In one of the paraffin histology sections of the globe enucleated 21 years previously a very small spindle B cell melanoma under the detached retina was present, with tumor cells in several vortex veins. The tumor was debulked centrally and it was exenterated and the eyelid skin was closed over the empty orbit. The patient is well 15 months after surgery. This case re-emphasizes that a choroidal melanoma can recur locally decennia after enucleation, that the histology of the tumor may change concomitantly and that a slowly growing orbital tumor can enlarge the bony orbit without perforating the periborbit or eroding the bone

    Visualization of sliding and deformation of orbital fat during eye rotation

    Get PDF
    PURPOSE: Little is known about the way orbital fat slides and/or deforms during eye movements. We compared two deformation algorithms from a sequence of MRI volumes to visualize this complex behavior. METHODS: Time-dependent deformation data were derived from motion-MRI volumes using Lucas and Kanade Optical Flow (LK3D) and nonrigid registration (B-splines) deformation algorithms. We compared how these two algorithms performed regarding sliding and deformation in three critical areas: the sclera-fat interface, how the optic nerve moves through the fat, and how the fat is squeezed out under the tendon of a relaxing rectus muscle. The efficacy was validated using identified tissue markers such as the lens and blood vessels in the fat. RESULTS: Fat immediately behind the eye followed eye rotation by approximately one-half. This was best visualized using the B-splines technique as it showed less ripping of tissue and less distortion. Orbital fat flowed around the optic nerve during eye rotation. In this case, LK3D provided better visualization as it allowed orbital fat tissue to split. The resolution was insufficient to visualize fat being squeezed out between tendon and sclera. CONCLUSION: B-splines performs better in tracking structures such as the lens, while LK3D allows fat tissue to split as should happen as the optic nerve slides through the fat. Orbital fat follows eye rotation by one-half and flows around the optic nerve during eye rotation. TRANSLATIONAL RELEVANCE: Visualizing orbital fat deformation and sliding offers the opportunity to accurately locate a region of cicatrization and permit an individualized surgical plan

    Modelling the cost-effectiveness of a newborn hearing screening programme:Usability and pitfalls

    Get PDF
    Objective: The EUSCREEN project concerns the study of European vision and hearing screening programmes. Part of the project was the development of a cost-effectiveness model to analyse such programmes. We describe the development and usability of an online tool to enable stakeholders to design, analyse or modify a newborn hearing screening (NHS) programme. Design: Data from literature, from existing NHS programmes, and observations by users were used to develop and refine the tool. Required inputs include prevalence of the hearing impairment, test sequence and its timing, attendance, sensitivity, and specificity of each screening step. Outputs include the number of cases detected and the costs of screening and diagnostics. Study sample: Eleven NHS programmes with reliable data. Results: Three analyses are presented, exploring the effect of low attendance, number of screening steps, testing in the maternity ward, or screening at a later age, on the benefits and costs of the programme. Knowledge of the epidemiology of a staged screening programme is crucial when using the tool. Conclusions: This study presents a tool intended to aid stakeholders to design a new or analyse an existing hearing screening programme in terms of benefits and costs.</p

    Mri-based visualisation of orbital fat deformation during eye motion

    Get PDF
    Summary. Orbital fat, or the fat behind the eye, plays an important role in eye movements. In order to gain a better understanding of orbital fat mobility during eye motion, MRI datasets of the eyes of two healthy subjects were acquired respectively in seven and fourteen different directions of gaze. After semi-automatic rigid registration, the Demons deformable registration algorithm was used to derive timedependent three-dimensional deformation vector fields from these datasets. Visualisation techniques were applied to these datasets in order to investigate fat mobility in specific regions of interest in the first subject. A qualitative analysis of the first subject showed that in two of the three regions of interest, fat moved half as much as the embedded structures. In other words, when the muscles and the optic nerve that are embedded in the fat move, the fat partly moves along with these structures and partly flows around them. In the second subject, a quantitative analysis was performed which showed a relation between the distance behind the sclera and the extent to which fat moves along with the optic nerve

    Construct validation of the Amblyopia and Strabismus Questionnaire (A&SQ) by factor analysis

    Get PDF
    Background: The Amblyopia and Strabismus Questionnaire (A&SQ) was previously developed to assess quality of life (QoL) in amblyopia and/or strabismus patients. Here, factor analysis with Varimax rotation was employed to confirm that the questions of the A&SQ correlated to dimensions of quality of life (QoL) in such patients. Methods: Responses on the A&SQ from three groups were analyzed: healthy adults (controls) (n = 53), amblyopia and/or strabismus patients (n = 72), and a historic cohort of amblyopes born between 1962-1972 and occluded between 1968-1974 (n = 173). The correlations among the responses to the 26 A&SQ items were factor-analysed by Principal Component Analysis (PCA). As the development of the A&SQ was intuitive-deductive, it was expected that the pattern of correlation could be explained by the five a priori hypothesized dimensions: fear of losing the better eye, distance estimation, visual disorientation, diplopia, and social contact and cosmetic problems. Distribution of questions along the factors derived by PCA was examined by orthogonal Varimax rotation. Results: Data from 296 respondents were analyzed. PCA provided that six factors (cutoff point eigenvalue >1.0) accumulatively explained 70.5% of the variance. All A&SQ dimensions but one matched with four factors found by Varimax rotation (factor loadings >0.50), while two factors pertained to the fifth dimension. The six factors explained 33.7% (social contact and cosmetic problems); 10.3% (near distance estimation); 8.7% (diplopia); 7.2% (visual disorientation); 6.3% (fear of losing the better eye); and 4.3% (far distance estimation), together 70.48% of the item variance. Conclusion: The highly explained variance in the A&SQ scores by the factors found by the PCA confirmed the a priori hypothesized dimensions of this QoL instrument

    Inventory of current EU paediatric vision and hearing screening programmes

    Get PDF
    OBJECTIVE: To examine the diversity in paediatric vision and hearing screening programmes in Europe. METHODS: Themes for comparison of screening programmes derived from literature were used to compile three questionnaires on vision, hearing, and public health screening. Tests used, professions involved, age, and frequency of testing seem to influence sensitivity, specificity, and costs most. Questionnaires were sent to ophthalmologists, orthoptists, otolaryngologists, and audiologists involved in paediatric screening in all EU full-member, candidate, and associate states. Answers were cross-checked. RESULTS: Thirty-nine countries participated; 35 have a vision screening programme, 33 a nation-wide neonatal hearing screening programme. Visual acuity (VA) is measured in 35 countries, in 71% of these more than once. First measurement of VA varies from three to seven years of age, but is usually before age five. At age three and four, picture charts, including Lea Hyvarinen, are used most; in children over four, Tumbling-E and Snellen. As first hearing screening test, otoacoustic emission is used most in healthy neonates, and auditory brainstem response in premature newborns. The majority of hearing testing programmes are staged; children are referred after 1-4 abnormal tests. Vision screening is performed mostly by paediatricians, ophthalmologists, or nurses. Funding is mostly by health insurance or state. Coverage was reported as >95% in half of countries, but reporting was often not first-hand. CONCLUSION: Largest differences were found in VA charts used (12), professions involved in vision screening (10), number of hearing screening tests before referral (1-4), and funding sources (8)
    corecore