19 research outputs found

    Avaliação funcional pulmonar em crianças e adolescentes asmáticos: comparação entre a micro espirometria e a espirometria convencional Pulmonary function tests in asthmatic children and adolescents: Comparison between a microspirometer and a conventional spirometer

    No full text
    INTRODUÇÃO: A espirometria é muito utilizada no diagnóstico e na quantificação dos distúrbios ventilatórios como a asma. O micro espirômetro é um equipamento portátil e de fácil utilização que pode substituir o espirômetro convencional, embora existam poucas evidências de sua acurácia. OBJETIVO: Comparar o micro espirômetro com o espirômetro convencional em crianças e adolescentes asmáticos. MÉTODO: Os aparelhos utilizados foram o Micro Spirometer, da marca Micro Medical, e o espirômetro convencional Cosmed-Pony graphic 3.5, ambos com turbinômetros (sensores de fluxo). Foram incluídos na amostra 62 crianças e adolescentes, de ambos os sexos, com idades compreendidas entre cinco e dezesseis anos, com diagnóstico clínico de asma, em acompanhamento em serviço de Pneumologia. Os exames espirométricos foram realizados dentro das normas da American Thoracic Society e da Associação Brasileira de Normas Técnicas. Primeiro realizou-se a micro espirometria e em seguida, com o mesmo paciente, realizou-se a espirometria convencional. Os parâmetros analisados em ambos os aparelhos foram: capacidade vital forçada, volume expiratório forçado no primeiro segundo e pico de fluxo expiratório. Os dados foram analisados através do teste t de Student (pareado) e do teste de correlação de Pearson. RESULTADOS: Obteve-se forte correlação entre os parâmetros analisados nos dois aparelhos: para volume expiratório forçado no primeiro segundo r = 0,97, para capacidade vital forçada r = 0,97, e para pico de fluxo expiratório r = 0,91. CONCLUSÃO: Os resultados demonstraram que o micro espirômetro é um equipamento diagnóstico útil, que pode ser utilizado quando o espirômetro convencional não estiver disponível.<br>BACKGROUND: Spirometry is widely used in the diagnosis and quantification of respiratory disorders such as asthma. A microspirometer is a portable and easily used apparatus that can substitute for a regular spirometer, although there is little evidence of its accuracy. OBJECTIVE: Tocompare the microspirometer to a regular spirometer for use in asthmatic children and adolescents. METHODS: The instruments used were a Micro Spirometer, manufactured by Micro Medical, and a conventional Cosmed Pony Graphic 3.5 spirometer, both with turbinometers (flow sensors). The study sample consisted of 62 children and adolescents, of both genders, clinically diagnosed with asthma and under treatment at a pulmonology clinic. Ages ranged from 5 and 16 years. All spirometric tests were carried out according to the guidelines established by the American Thoracic Society and by the Associacão Brasileira de Normas Técnicas (Brazilian Technical Standards Association). For each patient, microspirometry was performed first, followed by conventional spirometry. The parameters analyzed in both devices were forced vital capacity, forced expiratory volume in one second and peak expiratory flow. Data were analyzed using the Student's t-test and Pearson's correlation test. RESULTS: Strong correlations were found between the two devices in the parameters analyzed: forced expiratory volume in one second: r = 0.97; forced vital capacity: r = 0.97; and peak expiratory flow: r = 0.91. CONCLUSION: These results demonstrate that the microspirometer is a useful diagnostic tool that can be used when a conventional spirometer is unavailable

    Effect of oils sources on blood lipid parameters of commercial laying hens

    No full text
    The experiment was carried out to verify if total cholesterol, HDL-cholesterol and triacylglicerol plasma levels are affected when laying hens are fed rations containing different dietary oil sources. One hundred sixty 50 week-old hens, assigned to four treatments with five replicates using 8 hens per replicate were used. The experimental period was of 84 days divided in 3 cycles of 28 days each. In the last day of each cycle, blood samples of 2 hens per replicate were randomly choose and blood samples were collected. On the other hand, blood was also collected at 7 am, 11 am and 3 pm aiming to study the daily changes of these lipids. Blood lipid parameters were not affected by different dietary oil sources (p > 0.05); however, HDL-cholesterol did change during the day, giving evidence that this lipid is indeed involved in the egg yolk formation

    Determinantes da mortalidade neonatal: estudo caso-controle em Fortaleza, Ceará, Brasil Determinants of neonatal mortality: a case-control study in Fortaleza, Ceará State, Brazil

    No full text
    Este trabalho objetivou determinar os fatores preditores da mortalidade neonatal utilizando modelagem hierarquizada. Trata-se de estudo caso-controle, com 132 casos e 264 controles. Foram considerados casos os recém-nascidos que morreram antes de completar 28 dias, e os controles os sobreviventes, nascidos e filhos de mães residentes em Fortaleza, Ceará, Brasil. O modelo de análise de regressão logística hierarquizada identificou fatores associados ao óbito neonatal: raça materna com efeito protetor para raça parda/negra (OR = 0,23; IC95%: 0,09-0,56), tempo gasto entre o deslocamento de casa ao hospital > 30 minutos (OR = 3,12; IC95%: 1,34-7,25), tempo < 1h ou > 10h entre a internação e o parto (OR = 2,43; IC95%: 1,24-4,76) e pré-natal inadequado (OR = 2,03; IC95%: 1,03-3,99), baixo peso ao nascer (OR = 14,75; IC95%: 5,26-41,35), prematuridade (OR = 3,41; IC95%: 1,29-8,98) e sexo masculino (OR = 2,09; IC95%: 1,09-4,03). Nessa casuística, as mortes neonatais foram associadas à qualidade da assistência pré-natal e da assistência direta ao trabalho de parto.<br>This case-control study with 132 cases and 264 controls aimed to determine predictors of neonatal mortality using hierarchical modeling. Cases were defined as newborns that died within 28 days of birth, and controls as the survivors, among infants of mothers living in Fortaleza, Ceará State, Brazil. Hierarchical logistic regression identified factors associated with neonatal death: maternal race, with brown/black race showing a protective effect (OR = 0.23; IC95%: 0.09-0.56), time spent from home to the hospital > 30 minutes (OR = 3.12; 95%CI: 1.34-7.25), time < 1h or > 10 hours between hospital admission and delivery (OR = 2.43; 95%CI: 1.24-4.76), inadequate prenatal care (OR = 2.03; 95%CI: 1.03-3.99), low birth weight (OR = 14.75; 95%CI: 5.26-41.35), prematurity (OR = 3.41; 95%CI: 1.29-8.98), and male gender (OR = 2.09; 95%CI: 1.09-4.03). In this case series, neonatal deaths were associated with the quality of prenatal care and direct care during labor
    corecore