281 research outputs found

    The oxygen isotopic composition (18O/16O) in the dust of comet 67P/Churyumov-Gerasimenko measured by COSIMA on-board Rosetta

    Get PDF
    The oxygen isotopic ratio 18O/16O has been measured in cometary gas for a wide variety of comets, but the only measurements in cometary dust were performed by the Stardust cometary sample return mission. Most such measurements find a value of the ratio that is consistent with Vienna Standard Mean Ocean Water (VSMOW) within errors. In this work we present the result of a measurement, using the COSIMA (the COmetary Secondary Ion Mass Analyser) instrument on the Rosetta orbiter, of the oxygen isotopic ratio in dust from Comet 67P/Churyumov-Gerasimenko. Measuring the 18O/16O ratio with COSIMA is challenging for a number of reasons, but it is possible with a reasonable degree of precision. We find a result of 2.00 × 10−3 ± 1.2 × 10−4, which is consistent within errors with VSMOW.</p

    The 34S/32S isotopic ratio measured in the dust of comet 67P/Churyumov–Gerasimenko by Rosetta/COSIMA

    Get PDF
    The isotopic ratio 34S/32S has been measured in cometary gas for a few comets, but it has only been measured in cometary dust by stardust. The dust measurements find a value of the ratio that is consistent with the Vienna Canyon Diablo Troilite value of 0.0442 within errors, but there is more spread in the values from cometary gas. In this paper, we present the result of measurements of the sulphur isotopic ratio in dust from Comet 67P/Churyumov–Gerasimenko with the COSIMA instrument aboard the Rosetta spacecraft. We find a result of 0.0463 ± 0.0057, which is consistent within errors with the terrestrial value.</p

    Why Give Birth in Health Facility? Users' and Providers' Accounts of Poor Quality of Birth Care in Tanzania.

    Get PDF
    In Tanzania, half of all pregnant women access a health facility for delivery. The proportion receiving skilled care at birth is even lower. In order to reduce maternal mortality and morbidity, the government has set out to increase health facility deliveries by skilled care. The aim of this study was to describe the weaknesses in the provision of acceptable and adequate quality care through the accounts of women who have suffered obstetric fistula, nurse-midwives at both BEmOC and CEmOC health facilities and local community members. Semi-structured interviews involving 16 women affected by obstetric fistula and five nurse-midwives at maternity wards at both BEmOC and CEmOC health facilities, and Focus Group Discussions with husbands and community members were conducted between October 2008 and February 2010 at Comprehensive Community Based Rehabilitation in Tanzania and Temeke hospitals in Dar es Salaam, and Mpwapwa district in Dodoma region. Health care users and health providers experienced poor quality caring and working environments in the health facilities. Women in labour lacked support, experienced neglect, as well as physical and verbal abuse. Nurse-midwives lacked supportive supervision, supplies and also seemed to lack motivation. There was a consensus among women who have suffered serious birth injuries and nurse midwives staffing both BEmOC and CEmOC maternity wards that the quality of care offered to women in birth was inadequate. While the birth accounts of women pointed to failure of care, the nurses described a situation of disempowerment. The bad birth care experiences of women undermine the reputation of the health care system, lower community expectations of facility birth, and sustain high rates of home deliveries. The only way to increase the rate of skilled attendance at birth in the current Tanzanian context is to make facility birth a safer alternative than home birth. The findings from this study indicate that there is a long way to go

    Method validation and preliminary qualification of pharmacodynamic biomarkers employed to evaluate the clinical efficacy of an antisense compound (AEG35156) targeted to the X-linked inhibitor of apoptosis protein XIAP

    Get PDF
    Data are presented on pharmacodynamic (PD) method validation and preliminary clinical qualification of three PD biomarker assays. M65 Elisa, which quantitates different forms of circulating cytokeratin 18 (CK18) as putative surrogate markers of both apoptotic and nonapoptotic tumour cell death, was shown to be highly reproducible: calibration curve linearity r2=0.996, mean accuracy >91% and mean precision <3%, n=27. Employing recombinant (r) CK18 and caspase cleaved CK18 (CK18 Asp396 neo-epitope) as external standards, kit to kit reproducibly was <6% (n=19). rCK18 was stable in plasma for 4 months at −20°C and −80°C, for 4 weeks at 4°C and had a half-life of 2.3 days at 37°C. Cytokeratin 18 Asp396 NE, the M30 Apoptosense Elisa assay antigen, was stable in plasma for 6 months at −20°C and −80°C, for 3 months at 4°C, while its half-life at 37°C was 3.8 days. Within-day variations in endogenous plasma concentrations of the M30 and M65 antigens were assessed in two predose blood samples collected from a cohort of 15 ovarian cancer patients receiving carboplatin chemotherapy and were shown to be no greater than the variability associated with methods themselves. Between-day fluctuations in circulating levels of the M30 and M65 antigens and in XIAP mRNA levels measured in peripheral blood mononuclear cells by quantitative (q) RT–PCR were evaluated in two predose blood samples collected with a 5- to 7-day gap from 23 patients with advanced cancer enrolled in a phase I trial. The mean variation between the two pretreatment values ranged from 13 to 14 to 25%, respectively, for M65, M30 and qRT–PCR. These data suggest that the M30 and M65 Elisa's and qRT–PCR as PD biomarker assays have favourable performance characteristics for further investigation in clinical trials of anticancer agents which induce tumour apoptosis/necrosis or knockdown of the anti-apoptotic protein XIAP

    Pediatric appendicitis rupture rate: a national indicator of disparities in healthcare access

    Get PDF
    BACKGROUND: The U.S. National Healthcare Disparities Report is a recent effort to measure and monitor racial and ethnic disparities in health and healthcare. The Report is a work in progress and includes few indicators specific to children. An indicator worthy of consideration is racial/ethnic differences in the rate of bad outcomes for pediatric acute appendicitis. Bad outcomes for this condition are indicative of poor access to healthcare, which is amenable to social and healthcare policy changes. METHODS: We analyzed the KID Inpatient Database, a nationally representative sample of pediatric hospitalization, to compare rates of appendicitis rupture between white, African American, Hispanic and Asian children. We ran weighted logistic regression models to obtain national estimates of relative odds of rupture rate for the four groups, adjusted for developmental, biological, socioeconomic, health services and hospital factors that might influence disease outcome. RESULTS: Rupture was a much more burdensome outcome than timely surgery and rupture avoidance. Rupture cases had 97% higher hospital charges and 175% longer hospital stays than non-rupture cases on average. These burdens disproportionately affected minority children, who had 24% – 38% higher odds of appendicitis rupture than white children, adjusting for age and gender. These differences were reduced, but remained significant after adjusting for other factors. CONCLUSION: The racial/ethnic disparities in pediatric appendicitis outcome are large and are preventable with timely diagnosis and surgery for all children. Furthermore, estimating this disparity using the KID survey is a relatively straightforward process. Therefore pediatric appendicitis rupture rate is a good candidate for inclusion in the National Healthcare Disparities Report. As with most other health and healthcare disparities, efforts to reduce disparities in income, wealth and access to care will most likely improve the odds of favorable outcome for this condition as well

    Ensuring competency in end-of-life care: controlling symptoms

    Get PDF
    BACKGROUND: Palliative medicine is assuming an increasingly important role in patient care. The Education for Physicians in End-of-life Care (EPEC) Project is an ambitious program to increase core palliative care skills for all physicians. It is not intended to transmit specialty level competencies in palliative care. METHOD: The EPEC Curriculum was developed to be a comprehensive syllabus including trainer notes, multiple approaches to teaching the material, slides, and videos of clinical encounters to trigger discussion are provided. The content was developed through a combination of expert opinion, participant feedback and selected literature review. Content development was guided by the goal of teaching core competencies not included in the training of generalist and non-palliative medicine specialist physicians. RESULTS: Whole patient assessment forms the basis for good symptom control. Approaches to the medical management of pain, depression, anxiety, breathlessness (dyspnea), nausea/vomiting, constipation, fatigue/weakness and the symptoms common during the last hours of life are described. CONCLUSION: While some physicians will have specialist palliative care services upon which to call, most in the world will need to provide the initial approaches to symptom control at the end-of-life

    Influences de la sylviculture sur le risque de dégâts biotiques et abiotiques dans les peuplements forestiers

    Full text link
    • …
    corecore