55 research outputs found

    Interplay of disorder and interactions in subcritically tilted and anisotropic three-dimensional Weyl fermions

    Full text link
    We study the effects of disorder and Coulomb interactions on the physics of three-dimensional type-I Weyl fermions with tilted and anisotropic dispersions in a renormalization group approach. To lowest non-trivial loop order we show that the tendency of the Coulomb interactions to restore the symmetry of the dispersion in the semimetallic region of the phase diagram dominates the stabilization of the tilt and anisotropy favored by weak disorder. We argue that the topology of the renormalization flow of the disorder and Coulomb couplings is essentially determined by gauge invariance, so that these findings continue to hold qualitatively at any order in perturbation theory.Comment: 9+5 page

    The learning curve of laparoscopic, robot-assisted and transanal total mesorectal excisions:a systematic review

    Get PDF
    Background The standard treatment of rectal carcinoma is surgical resection according to the total mesorectal excision principle, either by open, laparoscopic, robot-assisted or transanal technique. No clear consensus exists regarding the length of the learning curve for the minimal invasive techniques. This systematic review aims to provide an overview of the current literature regarding the learning curve of minimal invasive TME. Methods A systematic literature search was performed. PubMed, Embase and Cochrane Library were searched for studies with the primary or secondary aim to assess the learning curve of either laparoscopic, robot-assisted or transanal TME for rectal cancer. The primary outcome was length of the learning curve per minimal invasive technique. Descriptive statistics were used to present results and the MINORS tool was used to assess risk of bias. Results 45 studies, with 7562 patients, were included in this systematic review. Length of the learning curve based on intraoperative complications, postoperative complications, pathological outcomes, or a composite endpoint using a risk-adjusted CUSUM analysis was 50 procedures for the laparoscopic technique, 32-75 procedures for the robot-assisted technique and 36-54 procedures for the transanal technique. Due to the low quality of studies and a high level of heterogeneity a meta-analysis could not be performed. Heterogeneity was caused by patient-related factors, surgeon-related factors and differences in statistical methods. Conclusion Current high-quality literature regarding length of the learning curve of minimal invasive TME techniques is scarce. Available literature suggests equal lengths of the learning curves of laparoscopic, robot-assisted and transanal TME. Well-designed studies, using adequate statistical methods are required to properly assess the learning curve, while taking into account patient-related and surgeon-related factors

    Magnetic monopole density and antiferromagnetic domain control in spin-ice iridates.

    Get PDF
    Magnetically frustrated systems provide fertile ground for complex behaviour, including unconventional ground states with emergent symmetries, topological properties, and exotic excitations. A canonical example is the emergence of magnetic-charge-carrying quasiparticles in spin-ice compounds. Despite extensive work, a reliable experimental indicator of the density of these magnetic monopoles is yet to be found. Using measurements on single crystals of Ho2Ir2O7 combined with dipolar Monte Carlo simulations, we show that the isothermal magnetoresistance is highly sensitive to the monopole density. Moreover, we uncover an unexpected and strong coupling between the monopoles on the holmium sublattice and the antiferromagnetically ordered iridium ions. These results pave the way towards a quantitative experimental measure of monopole density and demonstrate the ability to control antiferromagnetic domain walls using a uniform external magnetic field, a key goal in the design of next-generation spintronic devices

    In vivo sentinel lymph node identification using fluorescent tracer imaging in colon cancer:A systematic review and meta-analysis

    Get PDF
    Introduction: The use of fluorescence might improve the performance of the sentinel lymph node procedure in patients with colon cancer. This systematic review was conducted to gain insight in the performance and applicability of the sentinel lymph node procedure using fluorescence. Method: A systematic literature search was performed. Databases were searched for prospective studies concerning sentinel node identification using fluorescence in colon cancer. Detection rate, accuracy rate and sensitivity of the sentinel lymph node procedure were calculated for early stage (T1-T2) and more invasive (T3-T4) tumours. Results: Analyses of five included studies showed for respectively T3-T4 and T1-T2 tumours a detection rate of 90 % and 91 %, an accuracy rate of 77 % and 98 %, and a sensitivity of 30 % and 80 %. Conclusion: The sentinel lymph node procedure using fluorescence in early stage (T1-T2) colon cancer seems to be promising. Larger cohorts are necessary to confirm these results

    Wetting transitions of Ne

    Full text link
    We report studies of the wetting behavior of Ne on very weakly attractive surfaces, carried out with the Grand Canonical Monte Carlo method. The Ne-Ne interaction was taken to be of Lennard-Jones form, while the Ne-surface interaction was derived from an ab initio calculation of Chizmeshya et al. Nonwetting behavior was found for Li, Rb, and Cs in the temperature regime explored (i.e., T < 42 K). Drying behavior was manifested in a depleted fluid density near the Cs surface. In contrast, for the case of Mg (a more attractive potential) a prewetting transition was found near T= 28 K. This temperature was found to shift slightly when a corrugated potential was used instead of a uniform potential. The isotherm shape and the density profiles did not differ qualitatively between these cases.Comment: 22 pages, 12 figures, submitted to Phys. Rev.

    Monte Carlo Methods for Estimating Interfacial Free Energies and Line Tensions

    Full text link
    Excess contributions to the free energy due to interfaces occur for many problems encountered in the statistical physics of condensed matter when coexistence between different phases is possible (e.g. wetting phenomena, nucleation, crystal growth, etc.). This article reviews two methods to estimate both interfacial free energies and line tensions by Monte Carlo simulations of simple models, (e.g. the Ising model, a symmetrical binary Lennard-Jones fluid exhibiting a miscibility gap, and a simple Lennard-Jones fluid). One method is based on thermodynamic integration. This method is useful to study flat and inclined interfaces for Ising lattices, allowing also the estimation of line tensions of three-phase contact lines, when the interfaces meet walls (where "surface fields" may act). A generalization to off-lattice systems is described as well. The second method is based on the sampling of the order parameter distribution of the system throughout the two-phase coexistence region of the model. Both the interface free energies of flat interfaces and of (spherical or cylindrical) droplets (or bubbles) can be estimated, including also systems with walls, where sphere-cap shaped wall-attached droplets occur. The curvature-dependence of the interfacial free energy is discussed, and estimates for the line tensions are compared to results from the thermodynamic integration method. Basic limitations of all these methods are critically discussed, and an outlook on other approaches is given

    Relaxation of surface tension in the liquid-solid interfaces of Lennard-Jones liquids

    Get PDF
    We have established the surface tension relaxation time in the liquid-solid interfaces of Lennard-Jones (LJ) liquids by means of direct measurements in molecular dynamics (MD) simulations. The main result is that the relaxation time is found to be almost independent of the molecular structures and viscosity of the liquids (at seventy-fold change) used in our study and lies in such a range that in slow hydrodynamic motion the interfaces are expected to be at equilibrium. The implications of our results for the modelling of dynamic wetting processes and interpretation of dynamic contact angle data are discussed

    Radiologist experience and CT examination quality determine metastasis detection in patients with esophageal or gastric cardia cancer

    Get PDF
    We aimed to separate the influence of radiologist experience from that of CT quality in the evaluation of CT examinations of patients with esophageal or gastric cardia cancer. Two radiologists from referral centers ('expert radiologists') and six radiologists from regional non-referral centers ('non-expert radiologists') performed 240 evaluations of 72 CT examinations of patients diagnosed with esophageal or gastric cardia cancer between 1994 and 2003. We used conditional logistic regression analysis to calculate odds ratios (OR) for the likelihood of a correct diagnosis. Expert radiologists made a correct diagnosis of the presence or absence of distant metastases according to the gold standard almost three times more frequently (OR 2.

    Density Distribution in the Liquid Hg-Sapphire Interface

    Full text link
    We present the results of a computer simulation study of the liquid density distribution normal to the interface between liquid Hg and the reconstructed (0001) face of sapphire. The simulations are based on an extension of the self-consistent quantum Monte Carlo scheme previously used to study the structure of the liquid metal-vapor interface. The calculated density distribution is in very good agreement with that inferred from the recent experimental data of Tamam et al (J. Phys. Chem. Lett. 1, 1041-1045 (2010)). We conclude that, to account for the difference in structure between the liquid Hg-vapor and liquid-Hg-reconstructed (0001) Al2O3 interfaces, it is not necessary assume there is charge transfer from the Hg to the Al2O3. Rather, the available experimental data are adequately reproduced when the van der Waals interactions of the Al and O atoms with Hg atoms and the exclusion of electron density from Al2O3 via repulsion of the electrons from the closed shells of the ions in the solid are accounted for.Comment: 26 pages, 11 figure
    • …
    corecore