34 research outputs found

    First spectroscopic investigation of Anomalous Cepheid variables

    Full text link
    Anomalous Cepheids (ACEPs) are intermediate mass metal-poor pulsators mostly discovered in dwarf galaxies of the Local Group. However, recent Galactic surveys, including the Gaia DR3, found a few hundreds of ACEPs in the Milky Way. Their origin is not well understood. We aim to investigate the origin and evolution of Galactic ACEPs by studying for the first time the chemical composition of their atmospheres. We used UVES@VLT to obtain high-resolution spectra for a sample of 9 ACEPs belonging to the Galactic halo. We derived the abundances of 12 elements, including C, Na, Mg, Si, Ca, Sc, Ti, Cr, Fe, Ni, Y, and Ba. We complemented these data with literature abundances for an additional three ACEPs that were previously incorrectly classified as type II Cepheids, thus increasing the sample to a total of 12 stars. All the investigated ACEPs have an iron abundance [Fe/H]<−1.5<-1.5 dex as expected from theoretical predictions for these pulsators. The abundance ratios of the different elements to iron show that the ACEP's chemical composition is generally consistent with that of the Galactic halo field stars, except the Sodium, which is found overabundant in 9 out of the 11 ACEPs where it was measured, in close similarity with second-generation stars in the Galactic Globular Clusters. The same comparison with dwarf and ultra-faint satellites of the Milky Way reveals more differences than similarities so it is unlikely that the bulk of Galactic ACEPs originated in such a kind of galaxies which subsequently dissolved in the Galactic halo. The principal finding of this work is the unexpected overabundance of Sodium in ACEPs. We explored several hypotheses to explain this feature, finding that the most promising scenario is the evolution of low-mass stars in a binary system with either mass transfer or merging. Detailed modelling is needed to confirm this hypothesis.Comment: 15 Figures, 4 Tables, Accepted for publication on Astronomy & Astrophysic

    Temporal changes in the epidemiology, management, and outcome from acute respiratory distress syndrome in European intensive care units: a comparison of two large cohorts

    Get PDF
    Background: Mortality rates for patients with ARDS remain high. We assessed temporal changes in the epidemiology and management of ARDS patients requiring invasive mechanical ventilation in European ICUs. We also investigated the association between ventilatory settings and outcome in these patients. Methods: This was a post hoc analysis of two cohorts of adult ICU patients admitted between May 1–15, 2002 (SOAP study, n = 3147), and May 8–18, 2012 (ICON audit, n = 4601 admitted to ICUs in the same 24 countries as the SOAP study). ARDS was defined retrospectively using the Berlin definitions. Values of tidal volume, PEEP, plateau pressure, and FiO2 corresponding to the most abnormal value of arterial PO2 were recorded prospectively every 24&nbsp;h. In both studies, patients were followed for outcome until death, hospital discharge or for 60&nbsp;days. Results: The frequency of ARDS requiring mechanical ventilation during the ICU stay was similar in SOAP and ICON (327[10.4%] vs. 494[10.7%], p = 0.793). The diagnosis of ARDS was established at a median of 3 (IQ: 1–7) days after admission in SOAP and 2 (1–6) days in ICON. Within 24&nbsp;h of diagnosis, ARDS was mild in 244 (29.7%), moderate in 388 (47.3%), and severe in 189 (23.0%) patients. In patients with ARDS, tidal volumes were lower in the later (ICON) than in the earlier (SOAP) cohort. Plateau and driving pressures were also lower in ICON than in SOAP. ICU (134[41.1%] vs 179[36.9%]) and hospital (151[46.2%] vs 212[44.4%]) mortality rates in patients with ARDS were similar in SOAP and ICON. High plateau pressure (&gt; 29 cmH2O) and driving pressure (&gt; 14 cmH2O) on the first day of mechanical ventilation but not tidal volume (&gt; 8&nbsp;ml/kg predicted body weight [PBW]) were independently associated with a higher risk of in-hospital death. Conclusion: The frequency of and outcome from ARDS remained relatively stable between 2002 and 2012. Plateau pressure &gt; 29 cmH2O and driving pressure &gt; 14 cmH2O on the first day of mechanical ventilation but not tidal volume &gt; 8&nbsp;ml/kg PBW were independently associated with a higher risk of death. These data highlight the continued burden of ARDS and provide hypothesis-generating data for the design of future studies

    Structure and heme environment of beef liver catalase at 2.5 A resolution.

    No full text

    Structure and heme environment of beef liver catalase at 2.5 Ã… resolution

    No full text
    Most of the amino acid side chains of beef liver catalase were clearly identifiable in the 2.5 Å resolution electron-density map, and the results are in good agreement with the sequence [Schroeder, W. A., Shelton, J. R., Shelton, J. B., Roberson, B. &amp; Apell, G. (1969) Arch. Biochem. Biophys. 131, 653-655]. The tertiary structure of one subunit consists of a large antiparallel β -pleated sheet domain with helical insertions, followed by a smaller domain containing four α -helices. The heme group is buried at least 20 Å below the molecular surface and is accessible by a channel lined with hydrophobic residues. The proximal ligand is tyrosine-357, while histidine-74 and asparagine-147 re the important residues on the distal side of the heme. The inhibitor 3-amino-1,2,4-triazole, which has been shown to covalently bond to histidine-74, can be built into the heme cavity with its N(2) atom coordinated to the heme iron
    corecore