18 research outputs found

    Plasma Cleaning of Metallic Mirrors from Carbon-Containing Films - New Possibilities for In Situ Monitoring of the Efficiency of Wall Conditioning in Fusion Devices

    Get PDF
    The method proposed for measuring the erosion rate of the carbon film, pre-deposited on the mirror-like surface of the test metallic samples, directly during wall conditioning procedures in a fusion device. The practical realization of the method provided at the DSM-2 stand where deuterium plasma produced in conditions of electron resonance at frequency 2.45 GHz used for cleaning the samples. For controlling C-film thickness the time variation of electrical conductivity of the circuit '˜film+plasma+entire scheme' was measured. The final cleaning stage sets according to the saturation section corresponding to the resistance of the entire measuring scheme. To check the state of full purification of samples from a carbon-containing film the reflectance at normal incidence in the wavelength 220-650 nm was measured before C-film deposition, just after C-film deposition, and after finishing the cleaning procedure. In all cases (16 experiments) the approach of total resistance to the 'ntire resistance' of the scheme in use was supported by restoration of the reflectance of stainless steel samples to its initial value. The method can be reversed, i.e. allows one to control in situ the appearance of a contaminating layer growing on the surface of a metal sample, preliminary cleaned before being installed in a vacuum vessel

    Effects of water impact on optical properties of metallic mirror samples

    Get PDF
    The effects of exposure in water or water steam on optical properties of mirror samples fabricated of different metals were studied. Materials of samples were: tungsten, beryllium, molybdenum, stainless steel, nickel, copper, rhodium, and amorphous alloys of two compositions. The material of the mirror was found to play a decisive role in degree of impact of water or water vapor on mirror degradation. The most strongly degraded Mo and Cu mirror samples, and the lowest degradation was observed for SS and Rh/SS mirror samples. The reflectance can be restored practically initial level when after water impact procedure the mirrors are exposed to ions of Ar plasma with energy ≥100 eV up to ion fluence >10¹⁹ ion/cm².Вивчено ефекти впливу води або водяної пари на оптичні властивості зразків дзеркал, виготовлених з різних металів: молібдену, вольфраму, нержавіючої сталі, нікелю, міді, родію, берилію і аморфних сплавів двох композицій. Було виявлено, що матеріал дзеркала відіграє вирішальну роль у мірі впливу води або водяної пари на деградацію дзеркала. Найбільш сильно деградували Mo- і Cu- зразки, а найнижча деградація спостерігалася для дзеркал SS і Rh/SS. Коефіцієнт віддзеркалення може бути відновлений до практично початкового рівня, якщо після впливу води дзеркала піддаються впливу іонів Ar-плазми з енергією ≥100 еВ до іонного флюєнса >10¹⁹ іонів/см².Изучены эффекты воздействия воды или водяного пара на оптические свойства образцов зеркал, изготовленных из разных металлов: молибдена, вольфрама, нержавеющей стали, никеля, меди, родия, бериллия и аморфных сплавов двух композиций. Было обнаружено, что материал зеркала играет решающую роль в степени воздействия воды или водяного пара на деградацию зеркала. Наиболее сильно деградировали Mo- и Cu- образцы, а самая низкая деградация наблюдалась для зеркал SS и Rh/SS. Коэффициент отражения может быть восстановлен до практически начального уровня, если после воздействия воды зеркала подвергаются воздействию ионов Ar-плазмы с энергией ≥100 эВ до ионного флюенса >10¹⁹ ионов/см²

    The method for in situ monitoring of the quality of in-vessel mirrors in a fusion reactor

    No full text
    In laser and optical methods of plasma diagnostics in ITER the most critical components of the measurement schemes will be the First Mirrors (FM) facing the burning plasma and located rather close to plasma volume. It is very important to check regularly the working condition of FM surface in situ, e.g., to control the Quality of transmitted Image (IQ) or signal. In the present work we compare the results of measurements of IQ made in situ, directly on the plasma device DSM-2 during mirror exposure to ion bombardment, with a compact optical scheme in use, and the results of ex situ measurements (on the DIQ stand) – with two times longer distance to mirror (~2.5 meters).В лазерних та оптичних методах діагностики плазми в ITER’і критичним елементом схеми вимірювань є перше дзеркало (FM), розміщене в безпосередній близькості до плазмового шнура. Тому дуже важливо відстежувати стан поверхні in situ, наприклад, контролюючи якість переданого зображення (IQ). У даній роботі ми порівнюємо результати вимірювань IQ зроблених за допомогою компактної оптичної схеми in situ, безпосередньо під час експонування дзеркала на плазмовій установці DSM-2, з результатами ex situ- вимірювань (на DIQ стенді) – з більш віддаленим положенням дзеркала.В лазерных и оптических методах диагностики плазмы в ITER’е критичным элементом схемы измерений является первое зеркало (FM), размещённое в непосредственной близости к плазменному шнуру. Поэтому очень важно отслеживать состояние поверхности in situ, например, контролируя качество передаваемого изображения (IQ). Мы сравниваем результаты измерений IQ, сделанных с использованием компактной оптической схемой in situ, непосредственно во время экспонирования зеркала на плазменной установке DSM-2, с результатами ex situ- измерений (на DIQ стендe) – с более удалённым положением зеркала

    Measurements of wall conditioning rate at Uragan-2M

    No full text
    An experiment on chamber RF cleaning for 12 hours a day during 2 weeks with the subsequent vacuum pumping out was carried out. The plasma was produced by the UHF generator with the frequency of 2.4 GHz. Afterwards, the VHF generator working at the frequency of 132 MHz in a continuous mode was turned on and continued to work independently. The process of wall conditioning involved filling the chamber with H₂ under the pressure range inside the chamber of (1.8…2.0)·10⁻⁴ Torr. During the process of radio-frequency (RF) chamber cleaning the pumped out gas was condensed on the cryogenic trap surface. Afterwards the trap was cut off, heated up and the gas pressure Pg inside the cut off trap chamber was measured. The Pg dependence on both discharge power and condensation time period is analyzed. As a result of the RF cleaning the Pg pressure was reduced by 4…5 times. The vacuum pumping out speed was measured when filling the vacuum vessel with propane and nitrogen.Был проведен эксперимент по чистке стенок камеры в течение 2 недель по 12 часов в день с последующей откачкой камеры. Плазма создавалась СВЧ-генератором с частотой 2.4 ГГц и затем включался УКВ-генератор, работающий на частоте 132 МГц в непрерывном режиме, который в дальнейшем работал самостоятельно. Чистка производилась с напуском водорода в диапазоне давлений в камере (1.8...2.0)×10⁻⁴Торр. В процессе чистки камеры УКВ-разрядом производилась конденсация образовывающегося внутри камеры газа на охлажденную поверхность азотной ловушки. Затем ловушка отсекалась от насоса и от камеры установки, проводилось ее отепление и измерялось давление газа Pg в отсеченной камере ловушки. Показана зависимость Pg от мощности разряда и длительности конденсации. По результатам эксперимента отмечено снижение значений Pg в 5...6 раз. Проведено измерение скорости откачки вакуумной системы для пропана и азота.Було проведено експеримент з очищення стінок камери на протязі 2 тижнів по 12 годин на день з наступною відкачкою камери. Плазма створювалась НВЧ-генератором з робочою частотою 2.4 ГГц, після цього вмикався УКВ-генератор, що працював на частоті 132 МГц у безперервному режимі, який надалі працював самостійно. Очищення проводилось з напуском водню у діапазоні тиску в камері (1.8...2.0)×10⁻⁴ Торр. Протягом процесу чищення камери УКВ-розрядом проводилась конденсація газу, що створюється в камері, на охолоджену поверхню азотного уловлювача. Потім пастка відтиналася від насоса і від камери установки, проводилося ії утеплення й вимірювався тиск газу Pg у відсіченій камері пастки. Показано залежність Pg від потужності розряду та тривалості конденсації. За результатами експерименту відмічено зниження значень Pg у 5...6 разів. Проведено вимірювання швидкості відкачки вакуумної системи для пропану та азоту

    First results with collecting probes in U-2M torsatron

    No full text
    The results are presented on a postmortem analysis of the mirror-like SS samples and two glass samples exposed in the Uragan-2M (U-2M) vacuum chamber during experimental campaigns in 2015 and 2016 years. The examination of the samples, after their removal from the chamber, has revealed that all of them were coated with a carbon-containing film of thickness dependent on the sample position. All metal samples were easily cleaned by low energy ions of deuterium plasma, excluding the one located nearby the RF antenna, which was used for RF plasma production.Представленo результати аналізу поверхні зразків дзеркал з нержавіючої сталі і двох скляних зразків, експонованих у вакуумній камері установки Ураган-2М протягом двох експериментальних кампаній (2015 і 2016 рр.). Після вилучення зразків з вакуумної камери було виявлено, що всі вони покриті вуглецевмісною плівкою, товщина якої залежить від положення зразка. Всі металеві зразки були легко очищені від забруднюючого шару низькоенергетичними іонами дейтерієвої плазми, за винятком того, що розташовувався поблизу ВЧ-антени, яка використовувалася для створення плазми.Представлены результаты анализа поверхности образцов зеркал из нержавеющей стали и двух стеклянных образцов, экспонированных в вакуумной камере установки Ураган-2М в течение двух экспериментальных кампаний (2015 и 2016 гг.). После изъятия образцов из вакуумной камеры было обнаружено, что все они покрыты углеродсодержащей пленкой, толщина которой зависит от положения образца. Все металлические образцы были легко очищены от загрязняющего слоя низкоэнергетичными ионами дейтериевой плазмы, за исключением образца, располагавшегося вблизи ВЧ-антенны, которая использовалась для создания плазмы

    Specular and diffusive reflectance of stainless steel mirrors sputtered with Ar⁺ ions

    No full text
    It was shown that a light source with edge sharpness can be used for very sensitive measurements of the ratio of specular and diffusive components of reflectance of the mirror subjected to sputtering.Измерение изображения резко очерченного источника света, отраженного от зеркала (IQ-метод), является очень чувствительным методом регистрации соотношения зеркального и диффузного компонентов коэффициента отражения при распылении испытуемых образцов.Вимірювання зображення різко окресленого джерела світла, відбитого від дзеркала (IQ-метод), є дуже чутливим методом реєстрації співвідношення дзеркального та дифузного компонентів коефіцієнта відбиття при розпиленні випробовуваних зразків

    Effect of quasi-hydrostatic extrusion on microhardness in CuCrZr alloy

    No full text
    Effect of quasi-hydrostatic extrusion at liquid nitrogen (77 K) and room (300 K) temperatures on the microhardness in high-strength CuCrZr alloy has been investigated. It is shown that the combination of equalchannel angular compression (ECAP) and quasi-hydrostatic extrusion (QHE) allows raising microhardness of CuCrZr alloy especially in the case of the low-temperature (77 K) QHE treatment. PACS: 68.35.Ct, 81.05.Bx, 81.40.CdИсследовано влияние квазигидроэкструзии при температуре жидкого азота (77 K) и комнатной температуре (300 K) на микротвердость жаропрочного CuCrZr-сплава. Выявлено, что комбинация равноканального углового прессования (РКУП) и квазигидроэкструзии (КГЭ) приводит к увеличению микротвердости CuCrZr-сплава, особенно в случае низкотемпературной (77 K) КГЭ-обработки.Досліджено вплив квазігідроекструзії при температурі рідкого азоту (77 K) та кімнатній температурі (300 K) на мікротвердість жароміцного CuCrZr-сплаву. Визначено, що комбінація рівноканального кутового пресування (РККП) та квазігідроекструзії (КГЕ) призводить до підвищення мікротвердості CuCrZr-сплаву, особливо у випадку низькотемпературної (77 K) КГЕ-обробки

    The microrelief studies of stainless steel mirrors sputtered with Ar⁺ ions of different energy

    No full text
    Four stainless steel mirror specimens were sputtered to an identical mean thickness of the eroded layer 2 μm with Ar⁺ ions. Each specimen was exposed to ions with one kinetic energy from the followings: 300, 600, 1000, and 1350 eV. With the methods of microscopy and profilometry of microrelief the positive correlation was shown between the r. m. s. roughness, the power spectral density of the Fourier spectrum of the longitudinal wavelengths, on one hand, and the energy of ions, on the other hand.Чотири зразки дзеркал із нержавіючої сталі були розпилені до однакової середньої товщини еродованого шару 2 мкм іонами Ar⁺ . Кожен зразок експонувався до іонів з наступною кінетичною енергією:300, 600, 1000 і 1350 еВ. З використанням методів мікроскопії і профілометрії мікрорельєфу було показано позитивну кореляцію між середньоквадратичною шорсткістю, спектральною густиною потужності спектра Фур'є поздовжніх довжин хвиль з одного боку, та енергією іонів з іншого бокуЧетыре образца зеркал из нержавеющей стали были распылены до одинаковой средней толщины эродированного слоя 2 мкм ионами Ar⁺ . Каждый образец экспонировался к ионам со следующей кинетической энергией: 300, 600, 1000 и 1350 эВ. С использованием методов микроскопии и профилометрии микрорельефа была показана положительная корреляция между среднеквадратичной шероховатостью, спектральной плотностью мощности спектра Фурье продольных длин волн с одной стороны, и энергией ионов с другой стороны

    Simulating study of plasmachemical erosion of a-C:H films in a ECR discharge plasma

    No full text
    The dynamics of interference figure of the reflection spectrum for stainless steel and copper mirrors with specially deposited carbon-containing film (ɚ-C:H) were studied when the film was gradually eroded under impact of a deuterium plasma produced in conditions of electron cyclotron resonance (ECR). The refraction coefficient of the film was estimated and the rate of the film removal was obtained.Досліджувалася динаміка інтерференційної картини спектру віддзеркалення сталевих і мідних дзеркал з штучно нанесеною вуглецьвмісною плівкою (a-C:H) по мірі розпилювання в дейтерієвій плазмі ЕЦР-розряду. Проведена оцінка коефіцієнта заломлення плівки. Отримана кількісна оцінка швидкості розпилювання.Исследовалась динамика интерференционной картины спектра отражения стальных и медных зеркал с искусственно нанесенной углеродсодержащей пленкой (a-C:H) по мере распыления в дейтериевой плазме ЭЦР-разряда. Проведена оценка коэффициента преломления пленки. Получена количественная оценка скорости распыления

    The dynamics of inductively accelerated electrons in the U-3M torsatron

    No full text
    Additional experimental data for the runaway electrons flow in the Uragan-3M torsatron were obtained. In particular the synchrotron and ultrahigh frequency radiation were measured. Also the flow current dynamics was studied by Rogovski coil and toroidal loop. Finally the experiments with the runaway flow stimulation were carried out.Получены дополнительные экспериментальные данные о динамике потока убегающих электронов в торсатроне Ураган-3М. Произведены измерения синхротронного и СВЧ-излучения потока, получены результаты измерений тока потока и напряжения на обходе стелларатора. Кроме того, проведены эксперименты по стимуляции потока убегающих электронов.Отримано додаткові експериментальні дані щодо динаміки потоку утікаючих електронів у торсатроні Ураган-3М. Проведено вимірювання синхротронного та НВЧ-випромінювання потоку, отримано дані вимірювань струму потоку та напруги на обході стеларатора. Проведено експерименти зі стимуляції потоку утікаючих електронів
    corecore